Environmental biocontamination by SARS-CoV-2 Virus in the hospital setting

IF 4.8 Q1 MICROBIOLOGY Current Research in Microbial Sciences Pub Date : 2025-01-01 DOI:10.1016/j.crmicr.2025.100355
M Espejo Mambié , D San Jose-Saras , C Bischofberger Valdés , C Díaz-Agero Pérez , JC Galán Montemayor , L Martínez-García , M Abreu Di-Berardino , P Moreno-Nunez , J Vicente-Guijarro , J.M Aranaz-Andrés
{"title":"Environmental biocontamination by SARS-CoV-2 Virus in the hospital setting","authors":"M Espejo Mambié ,&nbsp;D San Jose-Saras ,&nbsp;C Bischofberger Valdés ,&nbsp;C Díaz-Agero Pérez ,&nbsp;JC Galán Montemayor ,&nbsp;L Martínez-García ,&nbsp;M Abreu Di-Berardino ,&nbsp;P Moreno-Nunez ,&nbsp;J Vicente-Guijarro ,&nbsp;J.M Aranaz-Andrés","doi":"10.1016/j.crmicr.2025.100355","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Demonstrating the capability to isolate biological material from the environment was fundamental to supporting any transmission route. Various and inconsistent methodologies have been used to address this issue; however, the debate in scientific societies about the possibility of airborne transmission as a source of SARS-CoV-2 spread remained open.</div></div><div><h3>Objective</h3><div>To analyze SARS-CoV-2 contamination in the air and on surfaces in a hospital setting during the COVID-19 pandemic.</div></div><div><h3>Methods</h3><div>This study involved air and surface sampling in the emergency, hospitalization, and intensive care unit areas of the Ramón y Cajal University Hospital. A consistent methodology was used for all samples, and clinical and environmental parameters and characterization of each location were recorded.</div></div><div><h3>Results</h3><div>A total of 234 samples were collected, comprising 160 surface samples and 74 air samples, of which 6.84 % tested positive (13/160 surface samples and 3/74 air samples). High-contact surfaces had the highest proportion of positive samples (12/13). All positive air samples were identified within 2 m of patients who had recently developed symptoms (&lt;5 days). High dependency and elevated temperatures seemed to indicate a higher risk of environmental biocontamination. Additionally, there was a higher risk of contamination in the intensive care units than in the hospitalization or emergency units.</div></div>","PeriodicalId":34305,"journal":{"name":"Current Research in Microbial Sciences","volume":"8 ","pages":"Article 100355"},"PeriodicalIF":4.8000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Research in Microbial Sciences","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666517425000173","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Demonstrating the capability to isolate biological material from the environment was fundamental to supporting any transmission route. Various and inconsistent methodologies have been used to address this issue; however, the debate in scientific societies about the possibility of airborne transmission as a source of SARS-CoV-2 spread remained open.

Objective

To analyze SARS-CoV-2 contamination in the air and on surfaces in a hospital setting during the COVID-19 pandemic.

Methods

This study involved air and surface sampling in the emergency, hospitalization, and intensive care unit areas of the Ramón y Cajal University Hospital. A consistent methodology was used for all samples, and clinical and environmental parameters and characterization of each location were recorded.

Results

A total of 234 samples were collected, comprising 160 surface samples and 74 air samples, of which 6.84 % tested positive (13/160 surface samples and 3/74 air samples). High-contact surfaces had the highest proportion of positive samples (12/13). All positive air samples were identified within 2 m of patients who had recently developed symptoms (<5 days). High dependency and elevated temperatures seemed to indicate a higher risk of environmental biocontamination. Additionally, there was a higher risk of contamination in the intensive care units than in the hospitalization or emergency units.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Current Research in Microbial Sciences
Current Research in Microbial Sciences Immunology and Microbiology-Immunology and Microbiology (miscellaneous)
CiteScore
7.90
自引率
0.00%
发文量
81
审稿时长
66 days
期刊最新文献
Human microbiome in post-acute COVID-19 syndrome (PACS) Multifaceted virus-like particles: Navigating towards broadly effective influenza A virus vaccines Evaluation and identification of metabolites produced by Cytobacillus firmus in the interaction with Arabidopsis thaliana plants and their effect on Solanum lycopersicum Antibacterial potential and phytochemical analysis of two ethnomedicinally important plants The role of universal stress protein Usp1413 in meropenem adaptive resistance and environmental stress responses in Acinetobacter baumannii
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1