Accuracy of 3D printing template-assisted CT-guided radioactive iodine-125 seed implantation for peripheral locally recurrent rectal cancer: A retrospective study

Xuemin Li, Hao Wang, Yuliang Jiang, Zhe Ji, Haitao Sun, Jinghong Fan, Weiyan Li, Junjie Wang
{"title":"Accuracy of 3D printing template-assisted CT-guided radioactive iodine-125 seed implantation for peripheral locally recurrent rectal cancer: A retrospective study","authors":"Xuemin Li,&nbsp;Hao Wang,&nbsp;Yuliang Jiang,&nbsp;Zhe Ji,&nbsp;Haitao Sun,&nbsp;Jinghong Fan,&nbsp;Weiyan Li,&nbsp;Junjie Wang","doi":"10.1002/msp2.55","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objective</h3>\n \n <p>This study aimed to investigate the accuracy of needle insertion and dosimetric parameters in three-dimensional printing template (3D-PT)-assisted computed tomography (CT)-guided radioactive iodine-125 (<sup>125</sup>I) seed implantation (RISI) for the treatment of peripheral locally recurrent rectal cancer (pLRRC).</p>\n </section>\n \n <section>\n \n <h3> Materials and methods</h3>\n \n <p>A total of 37 patients with pLRRC who underwent 3D-assisted CT-guided RISI treatment at Peking University Third Hospital between January 2016 and November 2019 were included in this study. All patients underwent preoperative assessment, CT simulation positioning, preoperative plan design, 3D template printing, 3D template reduction, needle and seed implantation, postoperative dosimetry evaluation, postoperative care, and regular follow-up. The preoperative and postoperative needle position, angle, and tip distance were compared. The dosimetric parameters, including D90 (the dose to 90% of the target volume), D100, V100 (the volume receives 100% of the prescribed dose), V150, V200, conformal index (CI), external index (EI), and homogeneity index (HI), were compared among preoperative plan, intraoperative plan, and postoperative plan. The perioperative complications were assessed.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The total number of needles was 595. The depths of needle insertion in preoperative and intraoperative plans were 109.87 ± 1.33 mm and 108.46 ± 1.26 mm, respectively, with no significant difference (<i>p</i> &gt; 0.05). The angles of needle insertion in preoperative and intraoperative plans were (93.55 ± 2.05)° and (92.04 ± 1.99)°, respectively, with no significant difference (<i>p</i> &gt; 0.05). The average deviation of the needle insertion distance was 1.99 ± 0.08 mm. There were no differences in preoperative, intraoperative, and postoperative parameters, including D90, D100, V100, V150, V200, CI, EI, and HI. All patients were closely followed up during the perioperative period (from seven days before surgery to seven days after surgery). No patients experienced severe perioperative complications. A total of eight patients (21.6%) experienced grade 1−2 complications. Among all patients, six individuals (16.2%) experienced pain, one patient (2.7%) had a fever, and one patient (2.7%) suffered from a hemorrhage. All patients recovered after conservative treatment.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>The needle insertion in 3D-PT-assisted CT-guided RISI showed good accuracy for treating pLRRC.</p>\n </section>\n </div>","PeriodicalId":100882,"journal":{"name":"Malignancy Spectrum","volume":"1 4","pages":"323-331"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/msp2.55","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Malignancy Spectrum","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/msp2.55","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

This study aimed to investigate the accuracy of needle insertion and dosimetric parameters in three-dimensional printing template (3D-PT)-assisted computed tomography (CT)-guided radioactive iodine-125 (125I) seed implantation (RISI) for the treatment of peripheral locally recurrent rectal cancer (pLRRC).

Materials and methods

A total of 37 patients with pLRRC who underwent 3D-assisted CT-guided RISI treatment at Peking University Third Hospital between January 2016 and November 2019 were included in this study. All patients underwent preoperative assessment, CT simulation positioning, preoperative plan design, 3D template printing, 3D template reduction, needle and seed implantation, postoperative dosimetry evaluation, postoperative care, and regular follow-up. The preoperative and postoperative needle position, angle, and tip distance were compared. The dosimetric parameters, including D90 (the dose to 90% of the target volume), D100, V100 (the volume receives 100% of the prescribed dose), V150, V200, conformal index (CI), external index (EI), and homogeneity index (HI), were compared among preoperative plan, intraoperative plan, and postoperative plan. The perioperative complications were assessed.

Results

The total number of needles was 595. The depths of needle insertion in preoperative and intraoperative plans were 109.87 ± 1.33 mm and 108.46 ± 1.26 mm, respectively, with no significant difference (p > 0.05). The angles of needle insertion in preoperative and intraoperative plans were (93.55 ± 2.05)° and (92.04 ± 1.99)°, respectively, with no significant difference (p > 0.05). The average deviation of the needle insertion distance was 1.99 ± 0.08 mm. There were no differences in preoperative, intraoperative, and postoperative parameters, including D90, D100, V100, V150, V200, CI, EI, and HI. All patients were closely followed up during the perioperative period (from seven days before surgery to seven days after surgery). No patients experienced severe perioperative complications. A total of eight patients (21.6%) experienced grade 1−2 complications. Among all patients, six individuals (16.2%) experienced pain, one patient (2.7%) had a fever, and one patient (2.7%) suffered from a hemorrhage. All patients recovered after conservative treatment.

Conclusion

The needle insertion in 3D-PT-assisted CT-guided RISI showed good accuracy for treating pLRRC.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Issue Information Enhancing tumor radiotherapy sensitivity through metal nanomaterials: A comprehensive review Accuracy of 3D printing template-assisted CT-guided radioactive iodine-125 seed implantation for peripheral locally recurrent rectal cancer: A retrospective study Assessment of risk prediction scores for venous thromboembolism in ambulatory cancer patients with solid tumors receiving chemotherapy: A comparative analysis The mechanistic role of curcumin and its analogs in NSCLC: An evaluation of cell death in preclinical studies
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1