Reliability of Ultrasound Elastography According to Experience Level and Anatomic Location.

IF 1.9 2区 医学 Q2 ORTHOPEDICS Clinics in Orthopedic Surgery Pub Date : 2025-02-01 Epub Date: 2024-11-28 DOI:10.4055/cios24190
Seul-Gi Kim, Bongkyung Park, Kyosun Hwang, Woong Kyo Jeong
{"title":"Reliability of Ultrasound Elastography According to Experience Level and Anatomic Location.","authors":"Seul-Gi Kim, Bongkyung Park, Kyosun Hwang, Woong Kyo Jeong","doi":"10.4055/cios24190","DOIUrl":null,"url":null,"abstract":"<p><strong>Backgroud: </strong>Strain elastography (SE) and shear wave elastography (SWE) are emerging techniques for evaluating the elasticity of soft tissue. This study aimed to determine interobserver and intraobserver reliability for elasticity measurements of different tissues and anatomic locations using SE and SWE.</p><p><strong>Methods: </strong>Ten healthy adult male individuals with 20 upper extremities participated in this study. The elasticities of the wrist extensor muscle, the common extensor tendon, and supraspinatus tendon were measured. Strain ratio and shear wave velocity were measured twice by 2 different examiners (examiner 1 with over 20 years of experience in musculoskeletal sonography and examiner 2 with 1 year of experience). Interobserver and intraobserver reliability was assessed using the intraclass correlation coefficient (ICC).</p><p><strong>Results: </strong>The 10 individuals' age ranged from 28 to 35 years. In SE, interobserver reliabilities at the 3 anatomic locations (wrist extensor muscle, common extensor tendon, and supraspinatus tendon) showed fair to moderate agreement (ICC = 0.489, <i>p</i> = 0.076; ICC = 0.408, <i>p</i> = 0.131; and ICC = 0.296, <i>p</i> = 0.711, respectively). The intraobserver reliabilities of examiner 1 were moderate to substantial only at the wrist extensor muscle and the common extensor tendon (ICC = 0.563, <i>p</i> = 0.039 and ICC = 0.702, <i>p</i> = 0.006, respectively). In SWE, interobserver reliabilities for the wrist extensor muscle and the supraspinatus tendon were moderate to substantial (ICC = 0.756, <i>p</i> = 0.002 and ICC = 0.565, <i>p</i> = 0.039, respectively). The intraobserver reliabilities of examiner 1 at the 3 anatomic locations were almost perfect (ICC = 0.843, <i>p</i> = 0.001; ICC = 0.800, <i>p</i> = 0.001; and ICC = 0.825, <i>p</i> = 0.001, respectively). The results of examiner 2 showed almost perfect agreement at the wrist extensor muscle (ICC = 0.886, <i>p</i> = 0.001) and moderate to substantial agreement at the tendons of the common extensor and supraspinatus (ICC = 0.592, <i>p</i> = 0.029 and ICC = 0.682, <i>p</i> = 0.008, respectively).</p><p><strong>Conclusions: </strong>SWE is a reliable method for assessing the flexibility of soft tissue, but it is affected by expertise and the specific anatomical site.</p>","PeriodicalId":47648,"journal":{"name":"Clinics in Orthopedic Surgery","volume":"17 1","pages":"166-173"},"PeriodicalIF":1.9000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11791484/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinics in Orthopedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4055/cios24190","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Backgroud: Strain elastography (SE) and shear wave elastography (SWE) are emerging techniques for evaluating the elasticity of soft tissue. This study aimed to determine interobserver and intraobserver reliability for elasticity measurements of different tissues and anatomic locations using SE and SWE.

Methods: Ten healthy adult male individuals with 20 upper extremities participated in this study. The elasticities of the wrist extensor muscle, the common extensor tendon, and supraspinatus tendon were measured. Strain ratio and shear wave velocity were measured twice by 2 different examiners (examiner 1 with over 20 years of experience in musculoskeletal sonography and examiner 2 with 1 year of experience). Interobserver and intraobserver reliability was assessed using the intraclass correlation coefficient (ICC).

Results: The 10 individuals' age ranged from 28 to 35 years. In SE, interobserver reliabilities at the 3 anatomic locations (wrist extensor muscle, common extensor tendon, and supraspinatus tendon) showed fair to moderate agreement (ICC = 0.489, p = 0.076; ICC = 0.408, p = 0.131; and ICC = 0.296, p = 0.711, respectively). The intraobserver reliabilities of examiner 1 were moderate to substantial only at the wrist extensor muscle and the common extensor tendon (ICC = 0.563, p = 0.039 and ICC = 0.702, p = 0.006, respectively). In SWE, interobserver reliabilities for the wrist extensor muscle and the supraspinatus tendon were moderate to substantial (ICC = 0.756, p = 0.002 and ICC = 0.565, p = 0.039, respectively). The intraobserver reliabilities of examiner 1 at the 3 anatomic locations were almost perfect (ICC = 0.843, p = 0.001; ICC = 0.800, p = 0.001; and ICC = 0.825, p = 0.001, respectively). The results of examiner 2 showed almost perfect agreement at the wrist extensor muscle (ICC = 0.886, p = 0.001) and moderate to substantial agreement at the tendons of the common extensor and supraspinatus (ICC = 0.592, p = 0.029 and ICC = 0.682, p = 0.008, respectively).

Conclusions: SWE is a reliable method for assessing the flexibility of soft tissue, but it is affected by expertise and the specific anatomical site.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.50
自引率
4.00%
发文量
85
审稿时长
36 weeks
期刊最新文献
Posterior Acetabular Coverage of the Femoral Head in Sport-Related Posterior Hip Dislocation or Subluxation. Reliability of Ultrasound Elastography According to Experience Level and Anatomic Location. The Impact of Hospital Volume and Region on Mortality, Medical Costs, and Length of Hospital Stay in Elderly Patients Following Hip Fracture: A Nationwide Claims Database Analysis. Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle. Satisfactory Clinical Outcomes of Revision Anterior Cruciate Ligament Reconstruction Using Quadriceps Tendon-Patellar Bone Allograft.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1