Does the Proximal Humerus Nail with 2 Distal Screws Provide Sufficient Rotational Stability?

IF 1.9 2区 医学 Q2 ORTHOPEDICS Clinics in Orthopedic Surgery Pub Date : 2025-02-01 Epub Date: 2024-11-06 DOI:10.4055/cios23150
Ki Yong An, Tae Gyu Park, Min Young Kim
{"title":"Does the Proximal Humerus Nail with 2 Distal Screws Provide Sufficient Rotational Stability?","authors":"Ki Yong An, Tae Gyu Park, Min Young Kim","doi":"10.4055/cios23150","DOIUrl":null,"url":null,"abstract":"<p><strong>Backgroud: </strong>Proximal humerus nails, frequently used for managing proximal humerus fractures, significantly enhance rotational stability and reinforce fractured fragments. Few research exists regarding the optimal number and positioning of distal screws. This study aimed to assess the stability of diverse screw configurations and scrutinize screw distribution and bone stress via finite element analysis.</p><p><strong>Methods: </strong>The humerus intramedullary nail (Humerus Interlocking Nail System; TDM) underwent assessment using finite element analysis applied to a humerus model. Three groups were established based on varying distal screw numbers and locations: all 3 distal locking holes were used in group 1; 2 screws (dynamic hole and proximal static hole) in group 2, and 2 screws (dynamic hole and distal static hole) in group 3. Finite element analysis computed stress distribution within the implant and bone for each group. A 1-mm fracture gap was simulated at the surgical neck, and stress distributions were analyzed in both normal and osteoporotic bone models.</p><p><strong>Results: </strong>Using two screws did not compromise rotational stability. Stress distribution analysis revealed stability across all groups without reaching failure strength. Group 3 exhibited a minor rise in component 11 (direct stress [force per unit area] acting on the positive and negative 1 faces in the 1-axis. direction) and component 22 (direct stress [force per unit area] acting on the positive and negative 2 faces in the 2-axis direction) stress, remaining below failure strength thresholds. Group 1 exhibited the lowest von Mises stress in the nail and screws, while groups 2 and 3 did not reach failure strength levels. Findings remained consistent in the osteoporotic model.</p><p><strong>Conclusions: </strong>All 3 groups demonstrated rotational stability concerning stress distribution, indicating that using 2 screws for distal fixation does not adversely affect stability. This suggests the potential for saving surgical time and reducing radiation exposure without compromising stability.</p>","PeriodicalId":47648,"journal":{"name":"Clinics in Orthopedic Surgery","volume":"17 1","pages":"148-156"},"PeriodicalIF":1.9000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11791494/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinics in Orthopedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4055/cios23150","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/6 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Backgroud: Proximal humerus nails, frequently used for managing proximal humerus fractures, significantly enhance rotational stability and reinforce fractured fragments. Few research exists regarding the optimal number and positioning of distal screws. This study aimed to assess the stability of diverse screw configurations and scrutinize screw distribution and bone stress via finite element analysis.

Methods: The humerus intramedullary nail (Humerus Interlocking Nail System; TDM) underwent assessment using finite element analysis applied to a humerus model. Three groups were established based on varying distal screw numbers and locations: all 3 distal locking holes were used in group 1; 2 screws (dynamic hole and proximal static hole) in group 2, and 2 screws (dynamic hole and distal static hole) in group 3. Finite element analysis computed stress distribution within the implant and bone for each group. A 1-mm fracture gap was simulated at the surgical neck, and stress distributions were analyzed in both normal and osteoporotic bone models.

Results: Using two screws did not compromise rotational stability. Stress distribution analysis revealed stability across all groups without reaching failure strength. Group 3 exhibited a minor rise in component 11 (direct stress [force per unit area] acting on the positive and negative 1 faces in the 1-axis. direction) and component 22 (direct stress [force per unit area] acting on the positive and negative 2 faces in the 2-axis direction) stress, remaining below failure strength thresholds. Group 1 exhibited the lowest von Mises stress in the nail and screws, while groups 2 and 3 did not reach failure strength levels. Findings remained consistent in the osteoporotic model.

Conclusions: All 3 groups demonstrated rotational stability concerning stress distribution, indicating that using 2 screws for distal fixation does not adversely affect stability. This suggests the potential for saving surgical time and reducing radiation exposure without compromising stability.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.50
自引率
4.00%
发文量
85
审稿时长
36 weeks
期刊最新文献
Posterior Acetabular Coverage of the Femoral Head in Sport-Related Posterior Hip Dislocation or Subluxation. Reliability of Ultrasound Elastography According to Experience Level and Anatomic Location. The Impact of Hospital Volume and Region on Mortality, Medical Costs, and Length of Hospital Stay in Elderly Patients Following Hip Fracture: A Nationwide Claims Database Analysis. Unveiling and Validating a Modified Method to Assess Cervical Sagittal Alignment as an Effective Substitute for Conventional C2-7 Cobb Angle. Satisfactory Clinical Outcomes of Revision Anterior Cruciate Ligament Reconstruction Using Quadriceps Tendon-Patellar Bone Allograft.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1