{"title":"The design of paper-based electroanalytical microfluidic device coupled with post-synthesized molecularly imprinted polymers (rGO/Au@Ag2S/PANI/polyacrylamide) for the detection of streptomycin","authors":"Mina Adampourezare ,&nbsp;Karim Asadpour-Zeynali ,&nbsp;Miguel de la Guardia ,&nbsp;Jafar Ezzati Nazhad Dolatabadi","doi":"10.1016/j.snr.2025.100297","DOIUrl":null,"url":null,"abstract":"<div><div>A highly sensitive three-electrode paper-based microfluidic device has been developed for determinate of streptomycin. Ag/GQD/chitosan nano ink was used to construct reference and counter electrodes and Au@Ag<sub>2</sub>S/GQD/chitosan nano ink was used to construct working electrode. rGO/Au@Ag<sub>2</sub>S/anline nano-sheets were encapsulated with acrylamide as a functional monomer to create novel nano-sized molecular imprinted polymer (MIP) and was used for the modification of electrode working.</div><div>Paper substrate was modified for forming a hydrophobic region around the hydrophilic region on the filter paper and were suitable for the evaluation of target molecules in aqueous environment. All steps of making the MIP and non-imprinted polymer (NIP) sensors are illustrated by FE-SEM, Energy-dispersive X-ray spectroscopy (EDS), and FT-IR. CV and DPV techniques were applied for the measurement of the streptomycin. The fabricated device showed high sensitivity toward streptomycin, which was due to synergistic effects between catalytic properties, electrical conductivity of rGO/Au@Ag<sub>2</sub>S/anline /Polyacrylamide, and considerably increased numbers of imprinted sites. Using these techniques, streptomycin was determined in the linear range of 1pM to 1 μM with a limit of detection of 0.9 × 10<sup>−12</sup> M (Ip (μA) = -2.075x + 31.575, R<sup>2</sup>= 0.9983). The device provided good cyclic stability (RSD &lt; 0.05), high reproducibility and selectivity (RSD &lt; 0.05 obtained from five calibration plots) with a good repeatability (for both milk and serum samples, RSD &lt; 0.05). Finally, it should be noted that this device showed a good analytical performance for the detection of streptomycin in milk and serum samples.</div></div>","PeriodicalId":426,"journal":{"name":"Sensors and Actuators Reports","volume":"9 ","pages":"Article 100297"},"PeriodicalIF":6.5000,"publicationDate":"2025-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666053925000177","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

A highly sensitive three-electrode paper-based microfluidic device has been developed for determinate of streptomycin. Ag/GQD/chitosan nano ink was used to construct reference and counter electrodes and Au@Ag2S/GQD/chitosan nano ink was used to construct working electrode. rGO/Au@Ag2S/anline nano-sheets were encapsulated with acrylamide as a functional monomer to create novel nano-sized molecular imprinted polymer (MIP) and was used for the modification of electrode working.
Paper substrate was modified for forming a hydrophobic region around the hydrophilic region on the filter paper and were suitable for the evaluation of target molecules in aqueous environment. All steps of making the MIP and non-imprinted polymer (NIP) sensors are illustrated by FE-SEM, Energy-dispersive X-ray spectroscopy (EDS), and FT-IR. CV and DPV techniques were applied for the measurement of the streptomycin. The fabricated device showed high sensitivity toward streptomycin, which was due to synergistic effects between catalytic properties, electrical conductivity of rGO/Au@Ag2S/anline /Polyacrylamide, and considerably increased numbers of imprinted sites. Using these techniques, streptomycin was determined in the linear range of 1pM to 1 μM with a limit of detection of 0.9 × 10−12 M (Ip (μA) = -2.075x + 31.575, R2= 0.9983). The device provided good cyclic stability (RSD < 0.05), high reproducibility and selectivity (RSD < 0.05 obtained from five calibration plots) with a good repeatability (for both milk and serum samples, RSD < 0.05). Finally, it should be noted that this device showed a good analytical performance for the detection of streptomycin in milk and serum samples.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
9.60
自引率
0.00%
发文量
60
审稿时长
49 days
期刊介绍: Sensors and Actuators Reports is a peer-reviewed open access journal launched out from the Sensors and Actuators journal family. Sensors and Actuators Reports is dedicated to publishing new and original works in the field of all type of sensors and actuators, including bio-, chemical-, physical-, and nano- sensors and actuators, which demonstrates significant progress beyond the current state of the art. The journal regularly publishes original research papers, reviews, and short communications. For research papers and short communications, the journal aims to publish the new and original work supported by experimental results and as such purely theoretical works are not accepted.
期刊最新文献
Dual-mode ratiometric electrochemical and turn-on fluorescent probe for reliably detecting H2O2 in Parkinson's disease serum Ratiometric fluorescent biosensors for quantitative lactic acid detection using CdTe@CdS quantum dots and lactate oxidase Impact of molecular structure and plasticization of PVC membranes in the response of solid-state ion-selective electrodes Molecularly imprinted polypyrrole-modified screen-printed electrode: Toward a sensor for furfural derivatives determination Acoustic bubbles: Inducing cell interactions via trapping, patterning, and removal
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1