Massimo Cressoni, Paolo Cadringher, Anna Colarieti, Fatemeh Darvizeh, Andrea Cozzi, Claudio Cina, Moreno Zanardo, Federico Ambrogi, Davide Ippolito, Francesco Sardanelli
{"title":"Is there a need for a CT scan of the pancreatic phase? A perfusion and simulation study of the pancreas, an HCC, and the kidney cortex.","authors":"Massimo Cressoni, Paolo Cadringher, Anna Colarieti, Fatemeh Darvizeh, Andrea Cozzi, Claudio Cina, Moreno Zanardo, Federico Ambrogi, Davide Ippolito, Francesco Sardanelli","doi":"10.1055/a-2516-3176","DOIUrl":null,"url":null,"abstract":"<p><p>To explore the peak enhancement time of a hepatocellular carcinoma, the pancreas, and the kidney cortex and its determinants.We obtained a time enhancement curve from the perfusion CT scans of 11 advanced HCC patients (40 volumes at 1.25 s time interval, slab slice 90 mm, bolus of 50 ml of iodinated contrast agent, 350 g iodine/ml, flow 5 ml/s). Small regions of interest were drawn on the abdominal aorta, the HCC, the cortex of the right kidney, and on the pancreas. The behavior of the contrast agent in the capillary and in the surrounding tissue was further explored with a finite element model.The peak enhancement time of the pancreas did not differ from that of the HCC (10±3 vs. 11±4 s, p=0.9), while the peak enhancement time of the kidney tended to be a few seconds earlier (8±1 s, p=0.082 vs. pancreas and p=0.069 vs. kidney). Simulation showed that the time span in which the tissue enhancement remained within 10% of its peak value was similar across all capillary densities and ranged between 26-38 s for a capillary density of 0.00125 per mm to 30-60 s for a capillary density of 0.01.The plateau tissue enhancement clinically acquired in the \"late arterial phase\" should be adequate both for the detection of hypervascular liver lesions such as HCCs and for obtaining peak pancreatic enhancement to detect hypovascular lesions. · The peak tissue enhancement time of an HCC, the pancreas, and the kidney cortex is similar. · The tissue peak enhancement time in the arterial phase is at the end of bolus transit. · Simulation shows that tissue enhancement peak time is a function of capillary density. · Cressoni M, Cadringher P, Colarieti A et al. Is there a need for a CT scan of the pancreatic phase? A perfusion and simulation study of the pancreas, an HCC, and the kidney cortex. Rofo 2025; DOI 10.1055/a-2516-3176.</p>","PeriodicalId":21490,"journal":{"name":"Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2025-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2516-3176","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
To explore the peak enhancement time of a hepatocellular carcinoma, the pancreas, and the kidney cortex and its determinants.We obtained a time enhancement curve from the perfusion CT scans of 11 advanced HCC patients (40 volumes at 1.25 s time interval, slab slice 90 mm, bolus of 50 ml of iodinated contrast agent, 350 g iodine/ml, flow 5 ml/s). Small regions of interest were drawn on the abdominal aorta, the HCC, the cortex of the right kidney, and on the pancreas. The behavior of the contrast agent in the capillary and in the surrounding tissue was further explored with a finite element model.The peak enhancement time of the pancreas did not differ from that of the HCC (10±3 vs. 11±4 s, p=0.9), while the peak enhancement time of the kidney tended to be a few seconds earlier (8±1 s, p=0.082 vs. pancreas and p=0.069 vs. kidney). Simulation showed that the time span in which the tissue enhancement remained within 10% of its peak value was similar across all capillary densities and ranged between 26-38 s for a capillary density of 0.00125 per mm to 30-60 s for a capillary density of 0.01.The plateau tissue enhancement clinically acquired in the "late arterial phase" should be adequate both for the detection of hypervascular liver lesions such as HCCs and for obtaining peak pancreatic enhancement to detect hypovascular lesions. · The peak tissue enhancement time of an HCC, the pancreas, and the kidney cortex is similar. · The tissue peak enhancement time in the arterial phase is at the end of bolus transit. · Simulation shows that tissue enhancement peak time is a function of capillary density. · Cressoni M, Cadringher P, Colarieti A et al. Is there a need for a CT scan of the pancreatic phase? A perfusion and simulation study of the pancreas, an HCC, and the kidney cortex. Rofo 2025; DOI 10.1055/a-2516-3176.
期刊介绍:
Die RöFo veröffentlicht Originalarbeiten, Übersichtsartikel und Fallberichte aus dem Bereich der Radiologie und den weiteren bildgebenden Verfahren in der Medizin. Es dürfen nur Arbeiten eingereicht werden, die noch nicht veröffentlicht sind und die auch nicht gleichzeitig einer anderen Zeitschrift zur Veröffentlichung angeboten wurden. Alle eingereichten Beiträge unterliegen einer sorgfältigen fachlichen Begutachtung.
Gegründet 1896 – nur knapp 1 Jahr nach der Entdeckung der Röntgenstrahlen durch C.W. Röntgen – blickt die RöFo auf über 100 Jahre Erfahrung als wichtigstes Publikationsmedium in der deutschsprachigen Radiologie zurück. Sie ist damit die älteste radiologische Fachzeitschrift und schafft es erfolgreich, lange Kontinuität mit dem Anspruch an wissenschaftliches Publizieren auf internationalem Niveau zu verbinden. Durch ihren zentralen Platz im Verlagsprogramm stellte die RöFo die Basis für das heute umfassende und erfolgreiche Radiologie-Medienangebot im Georg Thieme Verlag.
Besonders eng verbunden ist die RöFo mit der Geschichte der Röntgengesellschaften in Deutschland und Österreich. Sie ist offizielles Organ von DRG und ÖRG und die Mitglieder der Fachgesellschaften erhalten die Zeitschrift im Rahmen ihrer Mitgliedschaft. Mit ihrem wissenschaftlichen Kernteil und dem eigenen Mitteilungsteil der Fachgesellschaften bietet die RöFo Monat für Monat ein Forum für den Austausch von Inhalten und Botschaften der radiologischen Community im deutschsprachigen Raum.