{"title":"Universal, sensitive, and visual sandwich-type biosensor based on nanogold-catalyzed reduction and its application for detecting C-reactive protein in serum by a portable colorimeter","authors":"Runhui Zhang ,&nbsp;Huaze Shao ,&nbsp;Xiumei Hu ,&nbsp;Yongshi Liang ,&nbsp;Hanren Chen ,&nbsp;Shiquan Zheng ,&nbsp;Lihong Liu","doi":"10.1016/j.snb.2025.137408","DOIUrl":null,"url":null,"abstract":"<div><div>We proposed a low-cost, high sensitive and universal point-of-care testing method of different dimension biomarkers based on the target-mediated catalytic reduction suppression of double-sequence aptamers-modified gold nanoparticles (dsApts@AuNPs) and NaBH<sub>4</sub> on the organic dyes (T-AAND). Herein, carcinoembryonic antigen, alpha-fetoprotein, C-reactive protein (CRP), thrombin, lipopolysaccharide, <em>Staphylococcus aureus</em>, and <em>Escherichia coli</em> were chosen as model biomarkers and all successfully detected, with limit of detections of 6.5 pg/mL, 12.7 pg/mL, 79.7 pg/mL, 34.2 fM, 459 fM, 718 CFU/mL, and 830 CFU/mL, respectively. Remarkably, the assay is completed in a single EP tube within 40 minutes, with on-site quantification performed using a $70 portable colorimeter and the cost of reagents for each test is $0.75. The CRP levels of 31 patients and 11 healthy volunteers achieved with the latex-enhanced immunoturbidimetry were high consistency with those of the spectrophotometry (<em>r</em> = 0.9964) and the colorimeter (<em>r</em> = 0.9619), demonstrating the accuracy of the new method. In conclusion, the T-AAND integrated a colorimeter is a superior approach for detecting biomarkers, especially in resource-limited settings.</div></div>","PeriodicalId":425,"journal":{"name":"Sensors and Actuators B: Chemical","volume":"431 ","pages":"Article 137408"},"PeriodicalIF":8.0000,"publicationDate":"2025-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators B: Chemical","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0925400525001832","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

We proposed a low-cost, high sensitive and universal point-of-care testing method of different dimension biomarkers based on the target-mediated catalytic reduction suppression of double-sequence aptamers-modified gold nanoparticles (dsApts@AuNPs) and NaBH4 on the organic dyes (T-AAND). Herein, carcinoembryonic antigen, alpha-fetoprotein, C-reactive protein (CRP), thrombin, lipopolysaccharide, Staphylococcus aureus, and Escherichia coli were chosen as model biomarkers and all successfully detected, with limit of detections of 6.5 pg/mL, 12.7 pg/mL, 79.7 pg/mL, 34.2 fM, 459 fM, 718 CFU/mL, and 830 CFU/mL, respectively. Remarkably, the assay is completed in a single EP tube within 40 minutes, with on-site quantification performed using a $70 portable colorimeter and the cost of reagents for each test is $0.75. The CRP levels of 31 patients and 11 healthy volunteers achieved with the latex-enhanced immunoturbidimetry were high consistency with those of the spectrophotometry (r = 0.9964) and the colorimeter (r = 0.9619), demonstrating the accuracy of the new method. In conclusion, the T-AAND integrated a colorimeter is a superior approach for detecting biomarkers, especially in resource-limited settings.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Sensors and Actuators B: Chemical
Sensors and Actuators B: Chemical 工程技术-电化学
CiteScore
14.60
自引率
11.90%
发文量
1776
审稿时长
3.2 months
期刊介绍: Sensors & Actuators, B: Chemical is an international journal focused on the research and development of chemical transducers. It covers chemical sensors and biosensors, chemical actuators, and analytical microsystems. The journal is interdisciplinary, aiming to publish original works showcasing substantial advancements beyond the current state of the art in these fields, with practical applicability to solving meaningful analytical problems. Review articles are accepted by invitation from an Editor of the journal.
期刊最新文献
Three-dimensional DNA nanoamplifiers actuated by demethylase-activated deoxyribozyme for the ultrasensitive detection of FTO in human breast tissues K+ concentration-based NMR-fluorescence dual-functional senescence sensing using graphene quantum dots with crown ether structure Rational engineering of an optimized near-infrared fluorogenic sensor for efficient discovery of potent Notum inhibitors as anti-osteoporosis agents Closed loop acquisition of multi-levels humidity sensors by spontaneous optimization TiO2/Ti3C2Tx heterojunction without artificial intervention Improving CO2 resistance in high-temperature humidity sensors using LaFeO3 sensing electrodes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1