Dose-volume parameter evaluation of a sub-fractionation workflow for adaptive radiotherapy of prostate cancer patients on a 1.5 T magnetic resonance imaging radiotherapy system

Georgios Tsekas, Cornel Zachiu, Gijsbert H. Bol, Jochem R.N. van der Voort van Zyp, Sandrine M.G. van de Pol, Johannes C.J. de Boer, Bas W. Raaymakers
{"title":"Dose-volume parameter evaluation of a sub-fractionation workflow for adaptive radiotherapy of prostate cancer patients on a 1.5 T magnetic resonance imaging radiotherapy system","authors":"Georgios Tsekas,&nbsp;Cornel Zachiu,&nbsp;Gijsbert H. Bol,&nbsp;Jochem R.N. van der Voort van Zyp,&nbsp;Sandrine M.G. van de Pol,&nbsp;Johannes C.J. de Boer,&nbsp;Bas W. Raaymakers","doi":"10.1016/j.phro.2025.100706","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and purpose:</h3><div>This study focuses on evaluating a sub-fractionation workflow for intrafraction motion mitigation of prostate cancer patients on a 1.5 T magnetic resonance imaging radiotherapy system.</div></div><div><h3>Materials and methods:</h3><div>The investigated workflow consisted of two sub-fractions where intrafraction drift correction steps were applied based on a daily reference plan. However, the daily contours were only rigidly shifted to match the intrafraction anatomies and therefore the clinical dosimetric constraints might be violated. In this work, daily contours were deformed to match the intrafraction anatomies and the online plans were re-calculated for a total of 15 patients. The deformed prostate contours were inspected by radiation oncologists and corrections were performed when necessary. Finally, a dose-volume parameter evaluation was performed on a sub-fraction level using the clinical plan parameters.</div></div><div><h3>Results:</h3><div>Clinically acceptable coverage was reported for the target structures resulting in mean V<sub>95%</sub> of 99.7 % and 97.8 % for the clinical target volume (CTV) and planning target volume (PTV) respectively. Sub-fractions with insufficient CTV dose can be explained by the presence of intrafraction rotations and deformations that were not taken into account during intrafraction corrections. Additionally, for no sub-fraction the dose to the organs-at-risk exceeded the clinical constraints.</div></div><div><h3>Conclusion:</h3><div>Given our results on the CTV coverage we can conclude that the sub-fractionation workflow met the dosimetric constraints for the hypofractionated treatment of the analyzed group of prostate cancer patients. A future dose accumulation study can provide further insights into the suitability of the clinical margins.</div></div>","PeriodicalId":36850,"journal":{"name":"Physics and Imaging in Radiation Oncology","volume":"33 ","pages":"Article 100706"},"PeriodicalIF":3.4000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics and Imaging in Radiation Oncology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2405631625000119","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and purpose:

This study focuses on evaluating a sub-fractionation workflow for intrafraction motion mitigation of prostate cancer patients on a 1.5 T magnetic resonance imaging radiotherapy system.

Materials and methods:

The investigated workflow consisted of two sub-fractions where intrafraction drift correction steps were applied based on a daily reference plan. However, the daily contours were only rigidly shifted to match the intrafraction anatomies and therefore the clinical dosimetric constraints might be violated. In this work, daily contours were deformed to match the intrafraction anatomies and the online plans were re-calculated for a total of 15 patients. The deformed prostate contours were inspected by radiation oncologists and corrections were performed when necessary. Finally, a dose-volume parameter evaluation was performed on a sub-fraction level using the clinical plan parameters.

Results:

Clinically acceptable coverage was reported for the target structures resulting in mean V95% of 99.7 % and 97.8 % for the clinical target volume (CTV) and planning target volume (PTV) respectively. Sub-fractions with insufficient CTV dose can be explained by the presence of intrafraction rotations and deformations that were not taken into account during intrafraction corrections. Additionally, for no sub-fraction the dose to the organs-at-risk exceeded the clinical constraints.

Conclusion:

Given our results on the CTV coverage we can conclude that the sub-fractionation workflow met the dosimetric constraints for the hypofractionated treatment of the analyzed group of prostate cancer patients. A future dose accumulation study can provide further insights into the suitability of the clinical margins.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Physics and Imaging in Radiation Oncology
Physics and Imaging in Radiation Oncology Physics and Astronomy-Radiation
CiteScore
5.30
自引率
18.90%
发文量
93
审稿时长
6 weeks
期刊最新文献
Evaluation of artificial intelligence-based autosegmentation for a high-performance cone-beam computed tomography imaging system in the pelvic region Translation of dynamic contrast-enhanced imaging onto a magnetic resonance-guided linear accelerator in patients with head and neck cancer Normal tissue complication probability model for severe radiation-induced lymphopenia in patients with pancreatic cancer treated with concurrent chemoradiotherapy Recommendations for reporting and evaluating proton therapy beyond dose and constant relative biological effectiveness Investigating the potential of diffusion tensor atlases to generate anisotropic clinical tumor volumes in glioblastoma patients
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1