Institutional Variability in Ultrafast Breast MR Imaging: Comparing Compressed Sensing and View Sharing Techniques with Different Patient Populations and Contrast Injection Protocols.

Maya Honda, Masako Kataoka, Mami Iima, Rie Ota, Aika Okazawa, Yasuhiro Fukushima, Marcel Dominik Nickel, Fumiaki Sato, Norikazu Masuda, Tsutomu Okada, Yuji Nakamoto
{"title":"Institutional Variability in Ultrafast Breast MR Imaging: Comparing Compressed Sensing and View Sharing Techniques with Different Patient Populations and Contrast Injection Protocols.","authors":"Maya Honda, Masako Kataoka, Mami Iima, Rie Ota, Aika Okazawa, Yasuhiro Fukushima, Marcel Dominik Nickel, Fumiaki Sato, Norikazu Masuda, Tsutomu Okada, Yuji Nakamoto","doi":"10.2463/mrms.mp.2024-0152","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the institutional variability in ultrafast dynamic contrast-enhanced (UF-DCE) breast MRI using time-resolved angiography with stochastic trajectories (TWIST)-volumetric interpolated breath-hold examination (VIBE) and compressed sensing (CS)-VIBE sequences acquired at 2 different institutions with different patient populations and contrast injection protocols.</p><p><strong>Methods: </strong>UF-DCE MR images of 18 patients from site A acquired using a TWIST-VIBE sequence, and UF-DCE MR images of 18 patients from site B acquired with a CS-VIBE sequence, were retrospectively evaluated and compared. The 2-site patient cohort was matched for patient age, background parenchymal enhancement, malignancy or benignity, and lesion size. Qualitative assessments included noise, blurring, poor fat suppression, aliasing artifact, motion artifact, lesion conspicuity, lesion morphology, time-intensity-curve smoothness, and vessel delineation. For quantitative assessment, the bolus arrival time was evaluated for each lesion, and its diagnostic performance in discriminating between benign and malignant lesions was examined using receiver operating characteristics analysis.</p><p><strong>Results: </strong>Thirteen malignant and five benign lesions were included from each site. Qualitative evaluation revealed that poor fat suppression and aliasing artifacts were visible in images from site A with TWIST-VIBE (P = 0.004 and P < 0.001), whereas motion artifacts were present in images from site B with CS-VIBE (P = 0.04). Lesion morphology assessments (P < 0.001) and vessel delineation (P < 0.001) were superior for images from site B with CS-VIBE. Bolus arrival time was significantly longer with TWIST-VIBE than with CS-VIBE, for both benign and malignant lesions (P < 0.001). The area under the receiver operating characteristics curve was 0.55 for site A and 0.69 for site B (P = 0.39).</p><p><strong>Conclusion: </strong>Both acquisitions allowed evaluation of breast lesions with good lesion conspicuity and time-intensity-curve smoothness, whereas CS-VIBE was superior to TWIST-VIBE for morphological evaluation of breast lesions and depiction of blood vessels in the breast. Injection rate appears to have a significant impact on semi-quantitative parameters derived from UF-DCE MRI.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-02-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2463/mrms.mp.2024-0152","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To assess the institutional variability in ultrafast dynamic contrast-enhanced (UF-DCE) breast MRI using time-resolved angiography with stochastic trajectories (TWIST)-volumetric interpolated breath-hold examination (VIBE) and compressed sensing (CS)-VIBE sequences acquired at 2 different institutions with different patient populations and contrast injection protocols.

Methods: UF-DCE MR images of 18 patients from site A acquired using a TWIST-VIBE sequence, and UF-DCE MR images of 18 patients from site B acquired with a CS-VIBE sequence, were retrospectively evaluated and compared. The 2-site patient cohort was matched for patient age, background parenchymal enhancement, malignancy or benignity, and lesion size. Qualitative assessments included noise, blurring, poor fat suppression, aliasing artifact, motion artifact, lesion conspicuity, lesion morphology, time-intensity-curve smoothness, and vessel delineation. For quantitative assessment, the bolus arrival time was evaluated for each lesion, and its diagnostic performance in discriminating between benign and malignant lesions was examined using receiver operating characteristics analysis.

Results: Thirteen malignant and five benign lesions were included from each site. Qualitative evaluation revealed that poor fat suppression and aliasing artifacts were visible in images from site A with TWIST-VIBE (P = 0.004 and P < 0.001), whereas motion artifacts were present in images from site B with CS-VIBE (P = 0.04). Lesion morphology assessments (P < 0.001) and vessel delineation (P < 0.001) were superior for images from site B with CS-VIBE. Bolus arrival time was significantly longer with TWIST-VIBE than with CS-VIBE, for both benign and malignant lesions (P < 0.001). The area under the receiver operating characteristics curve was 0.55 for site A and 0.69 for site B (P = 0.39).

Conclusion: Both acquisitions allowed evaluation of breast lesions with good lesion conspicuity and time-intensity-curve smoothness, whereas CS-VIBE was superior to TWIST-VIBE for morphological evaluation of breast lesions and depiction of blood vessels in the breast. Injection rate appears to have a significant impact on semi-quantitative parameters derived from UF-DCE MRI.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Breast Diffusion-weighted MR Imaging: Current Applications, Insights from Screening, and Future Directions. Institutional Variability in Ultrafast Breast MR Imaging: Comparing Compressed Sensing and View Sharing Techniques with Different Patient Populations and Contrast Injection Protocols. MR Imaging Indices for Brain Interstitial Fluid Dynamics and the Effects of Orexin Antagonists on Sleep. Toward Clinical Implementation of Magnetic Resonance Imaging for Placental Function. Computational Design of a Thermal Applicator for Brain Hyperthermia Controlled by Capacitor Positioning in Loop Coils.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1