Development of an Infant Air-Jet Dry Powder Aerosol Delivery System (iDP-ADS) Including a New Multifunctional Bifurcating Two-Prong Nasal Interface.

IF 3.5 3区 医学 Q2 CHEMISTRY, MULTIDISCIPLINARY Pharmaceutical Research Pub Date : 2025-02-10 DOI:10.1007/s11095-024-03814-y
Sarah C Strickler, Dale R Farkas, Mohammad A M Momin, Laura Vargas, Ghali Aladwani, Michael Hindle, Worth Longest
{"title":"Development of an Infant Air-Jet Dry Powder Aerosol Delivery System (iDP-ADS) Including a New Multifunctional Bifurcating Two-Prong Nasal Interface.","authors":"Sarah C Strickler, Dale R Farkas, Mohammad A M Momin, Laura Vargas, Ghali Aladwani, Michael Hindle, Worth Longest","doi":"10.1007/s11095-024-03814-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To improve the quality of aerosol delivery to infants, the iDP-ADS was advanced to include dual-prong nose-to-lung aerosol administration with a bifurcating interface, consistently monitor lung pressures and control ventilatory parameters with a pressure monitoring and control (PMC) unit, and implement flexible nasal prongs for use across a range of subject sizes.</p><p><strong>Methods: </strong>Four bifurcating flow pathways were integrated into the iDP-ADS and tested in vitro with a full-term infant nose-throat (NT) model for comparison to the performance of a single-prong interface. After selecting the best-performing flow pathway, flexible prong designs were evaluated in the same model and chosen for additional testing. Realistic pulmonary mechanics (PM) and age-appropriate tidal volumes were used to simulate ventilation with the PMC unit and aerosol delivery in full-term and 34-week gestational age preterm NT models.</p><p><strong>Results: </strong>Three of the four bifurcating flow pathways matched the performance of the single-prong design (tracheal filter delivery of ~55%), and the FP4 design with co-flow was selected. A flexible prong version of FP4 produced similar performance to the rigid version. Measurements from the PMC unit demonstrated that consistent air volumes under safe operating pressures could be delivered with a PEEP between 4-6 cmH<sub>2</sub>O. Considering aerosol delivery, PM conditions resulted in ~4% decrease in filter deposition but high lung delivery efficiencies of ~45% and ~34% for the full-term and preterm models, respectively.</p><p><strong>Conclusions: </strong>The best-performing interface with flexible prongs matched the lung delivery efficiency of a high-transmission single-prong interface and delivered high aerosol doses through late-preterm to full-term NT models.</p>","PeriodicalId":20027,"journal":{"name":"Pharmaceutical Research","volume":" ","pages":""},"PeriodicalIF":3.5000,"publicationDate":"2025-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11095-024-03814-y","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To improve the quality of aerosol delivery to infants, the iDP-ADS was advanced to include dual-prong nose-to-lung aerosol administration with a bifurcating interface, consistently monitor lung pressures and control ventilatory parameters with a pressure monitoring and control (PMC) unit, and implement flexible nasal prongs for use across a range of subject sizes.

Methods: Four bifurcating flow pathways were integrated into the iDP-ADS and tested in vitro with a full-term infant nose-throat (NT) model for comparison to the performance of a single-prong interface. After selecting the best-performing flow pathway, flexible prong designs were evaluated in the same model and chosen for additional testing. Realistic pulmonary mechanics (PM) and age-appropriate tidal volumes were used to simulate ventilation with the PMC unit and aerosol delivery in full-term and 34-week gestational age preterm NT models.

Results: Three of the four bifurcating flow pathways matched the performance of the single-prong design (tracheal filter delivery of ~55%), and the FP4 design with co-flow was selected. A flexible prong version of FP4 produced similar performance to the rigid version. Measurements from the PMC unit demonstrated that consistent air volumes under safe operating pressures could be delivered with a PEEP between 4-6 cmH2O. Considering aerosol delivery, PM conditions resulted in ~4% decrease in filter deposition but high lung delivery efficiencies of ~45% and ~34% for the full-term and preterm models, respectively.

Conclusions: The best-performing interface with flexible prongs matched the lung delivery efficiency of a high-transmission single-prong interface and delivered high aerosol doses through late-preterm to full-term NT models.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Pharmaceutical Research
Pharmaceutical Research 医学-化学综合
CiteScore
6.60
自引率
5.40%
发文量
276
审稿时长
3.4 months
期刊介绍: Pharmaceutical Research, an official journal of the American Association of Pharmaceutical Scientists, is committed to publishing novel research that is mechanism-based, hypothesis-driven and addresses significant issues in drug discovery, development and regulation. Current areas of interest include, but are not limited to: -(pre)formulation engineering and processing- computational biopharmaceutics- drug delivery and targeting- molecular biopharmaceutics and drug disposition (including cellular and molecular pharmacology)- pharmacokinetics, pharmacodynamics and pharmacogenetics. Research may involve nonclinical and clinical studies, and utilize both in vitro and in vivo approaches. Studies on small drug molecules, pharmaceutical solid materials (including biomaterials, polymers and nanoparticles) biotechnology products (including genes, peptides, proteins and vaccines), and genetically engineered cells are welcome.
期刊最新文献
Ferric Ammonium Citrate Reduces Claudin-5 Abundance and Function in Primary Mouse Brain Endothelial Cells. In-vitro Evaluation of Solution Pressurised Metered Dose Inhaler Sprays with Low-GWP Propellants. Correction: Leveraging Model Master Files for Long-Acting Injectables. Development of an Infant Air-Jet Dry Powder Aerosol Delivery System (iDP-ADS) Including a New Multifunctional Bifurcating Two-Prong Nasal Interface. Prediction of the Extent of Blood-Brain Barrier Transport Using Machine Learning and Integration into the LeiCNS-PK3.0 Model.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1