Wearable CNT/PAni/fabric piezoresistive sensor for continuous blood pressure monitoring.

IF 3.4 Q2 ENGINEERING, BIOMEDICAL Wearable technologies Pub Date : 2025-02-10 eCollection Date: 2025-01-01 DOI:10.1017/wtc.2024.31
Milad Barati, Alireza Nikfarjam
{"title":"Wearable CNT/PAni/fabric piezoresistive sensor for continuous blood pressure monitoring.","authors":"Milad Barati, Alireza Nikfarjam","doi":"10.1017/wtc.2024.31","DOIUrl":null,"url":null,"abstract":"<p><p>Wearable pressure sensors with high sensitivity, fast response time, and low detection limit have great potential for blood pressure monitoring and early diagnosis of hypertension. This article introduces a piezoresistive pressure sensor based on carbon nanotubes (CNTs), polyaniline (PAni), and fabric (CNT/PAni/fabric) for health monitoring applications. This sensor is made by using two layers of linen fabric coated with CNT and PAni. These layers are placed on a polyester fabric substrate. One of the coated layers has a mesh structure, which increases the sensitivity of the sensor and lowers its detection limit. The CNT/PAni/fabric sensor has a high sensitivity of 2.035 kPa<sup>-1</sup> at pressures from 0 to 0.2 kPa, a response time of 290 ms, and a detection limit of 1.5 Pa. These features make it suitable for measuring blood pressure. The results obtained by measuring blood pressure using the pulse transit time method on four people, compared with the values obtained using the digital sphygmomanometer, show a discrepancy ranging between 0.019% and 1.62%. Also, the average error and standard deviation for the sensor measurement in systolic and diastolic pressures are 0.56 ± 0.33 and 0.57 ± 0.46, respectively, which shows that measurement with this sensor can be an alternative to existing devices.</p>","PeriodicalId":75318,"journal":{"name":"Wearable technologies","volume":"6 ","pages":"e6"},"PeriodicalIF":3.4000,"publicationDate":"2025-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11810520/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wearable technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1017/wtc.2024.31","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Wearable pressure sensors with high sensitivity, fast response time, and low detection limit have great potential for blood pressure monitoring and early diagnosis of hypertension. This article introduces a piezoresistive pressure sensor based on carbon nanotubes (CNTs), polyaniline (PAni), and fabric (CNT/PAni/fabric) for health monitoring applications. This sensor is made by using two layers of linen fabric coated with CNT and PAni. These layers are placed on a polyester fabric substrate. One of the coated layers has a mesh structure, which increases the sensitivity of the sensor and lowers its detection limit. The CNT/PAni/fabric sensor has a high sensitivity of 2.035 kPa-1 at pressures from 0 to 0.2 kPa, a response time of 290 ms, and a detection limit of 1.5 Pa. These features make it suitable for measuring blood pressure. The results obtained by measuring blood pressure using the pulse transit time method on four people, compared with the values obtained using the digital sphygmomanometer, show a discrepancy ranging between 0.019% and 1.62%. Also, the average error and standard deviation for the sensor measurement in systolic and diastolic pressures are 0.56 ± 0.33 and 0.57 ± 0.46, respectively, which shows that measurement with this sensor can be an alternative to existing devices.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.80
自引率
0.00%
发文量
0
审稿时长
11 weeks
期刊最新文献
Wearable CNT/PAni/fabric piezoresistive sensor for continuous blood pressure monitoring. An interactive soft robotic hand-task training system with wireless task boards and daily objects on post-stroke rehabilitation. From the idea to the user: a pragmatic multifaceted approach to testing occupational exoskeletons. Synergistic grasp analysis: A cross-sectional exploration using a multi-sensory data glove. A feasibility study on using soft insoles for estimating 3D ground reaction forces with incorporated 3D-printed foam-like sensors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1