Matthias Bantle, Annette Thierauf-Emberger, Alexandra Schröck, Wolfgang Weinmann, Lorenz M Bell
{"title":"Blood to serum concentration ratios for ethyl glucuronide and ethyl sulfate after five drinking episodes.","authors":"Matthias Bantle, Annette Thierauf-Emberger, Alexandra Schröck, Wolfgang Weinmann, Lorenz M Bell","doi":"10.1093/jat/bkaf006","DOIUrl":null,"url":null,"abstract":"<p><p>Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are mostly analyzed in urine; consequently, most kinetic studies are based on urine samples. In forensic cases, however, it may be necessary to determine these alcohol biomarkers in serum, whole blood or capillary blood. While there are sufficient data on EtG and EtS in serum after alcohol consumption, the amount of data available on whole blood concentrations is small. Therefore, data on corresponding blood-to-serum ratios seem to gain importance. This study provides data on a drinking experiment with 5 drinking episodes, where serum and whole blood samples were taken simultaneously from 11 healthy participants over 10 days. The samples were analyzed for EtG, EtS, and ethanol. EtG and EtS analysis in whole blood and serum were performed by LC -MS/MS; ethanol was determined by GC-FID and an ADH-based method. EtG and EtS reached their maximum concentration 4-7 hours after alcohol consumption. For EtG, a mean blood-to-serum ratio of 0.58 with a range from 0.38 to 0.73 was found; for EtS, the mean ratio was 0.81 with a range from 0.61 to 0.92, indicating a predominant distribution in the serum. For both analytes, high correlation coefficients were obtained when plotting concentrations in serum against concentrations in whole blood. Concerning elimination profiles of the individuals, no time or concentration dependence of EtG or EtS blood-to-serum ratios could be deduced. Neither for EtG nor for EtS a regularity of curve progressions could be observed in our test specimens.</p>","PeriodicalId":14905,"journal":{"name":"Journal of analytical toxicology","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of analytical toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/jat/bkaf006","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are mostly analyzed in urine; consequently, most kinetic studies are based on urine samples. In forensic cases, however, it may be necessary to determine these alcohol biomarkers in serum, whole blood or capillary blood. While there are sufficient data on EtG and EtS in serum after alcohol consumption, the amount of data available on whole blood concentrations is small. Therefore, data on corresponding blood-to-serum ratios seem to gain importance. This study provides data on a drinking experiment with 5 drinking episodes, where serum and whole blood samples were taken simultaneously from 11 healthy participants over 10 days. The samples were analyzed for EtG, EtS, and ethanol. EtG and EtS analysis in whole blood and serum were performed by LC -MS/MS; ethanol was determined by GC-FID and an ADH-based method. EtG and EtS reached their maximum concentration 4-7 hours after alcohol consumption. For EtG, a mean blood-to-serum ratio of 0.58 with a range from 0.38 to 0.73 was found; for EtS, the mean ratio was 0.81 with a range from 0.61 to 0.92, indicating a predominant distribution in the serum. For both analytes, high correlation coefficients were obtained when plotting concentrations in serum against concentrations in whole blood. Concerning elimination profiles of the individuals, no time or concentration dependence of EtG or EtS blood-to-serum ratios could be deduced. Neither for EtG nor for EtS a regularity of curve progressions could be observed in our test specimens.
期刊介绍:
The Journal of Analytical Toxicology (JAT) is an international toxicology journal devoted to the timely dissemination of scientific communications concerning potentially toxic substances and drug identification, isolation, and quantitation.
Since its inception in 1977, the Journal of Analytical Toxicology has striven to present state-of-the-art techniques used in toxicology labs. The peer-review process provided by the distinguished members of the Editorial Advisory Board ensures the high-quality and integrity of articles published in the Journal of Analytical Toxicology. Timely presentation of the latest toxicology developments is ensured through Technical Notes, Case Reports, and Letters to the Editor.