Variation in Layer-Specific Tear Properties of the Human Aorta Along Its Length and Circumference: Implications for Spatial Susceptibility to Dissection Initiation.

IF 1.7 4区 医学 Q4 BIOPHYSICS Journal of Biomechanical Engineering-Transactions of the Asme Pub Date : 2025-02-14 DOI:10.1115/1.4067912
Dimitrios P Sokolis
{"title":"Variation in Layer-Specific Tear Properties of the Human Aorta Along Its Length and Circumference: Implications for Spatial Susceptibility to Dissection Initiation.","authors":"Dimitrios P Sokolis","doi":"10.1115/1.4067912","DOIUrl":null,"url":null,"abstract":"<p><p>Hemodynamic variations influence the location of entry tears in aortic dissection. This study investigates whether variations in tear strength across the human aorta contribute to these clinical manifestations. Circumferential and axial strips were collected from nine axial and two circumferential sites along each autopsied aorta, yielding 1,188 samples (11 aortas × 18 sites × 2 directions × 3 layers per site). These samples underwent tear testing to assess tear strength and tear energy, constituting resistance to tear propagation. Adventitial tear parameters were significantly higher than those of the intima and media, with no significant differences between the latter two, supporting the observation that entry tears typically occur in the inner wall. Tear propagation angles were approximately 15 and 75 degrees for circumferential and axial medial strips, and 30 and 45 degrees for circumferential and axial strips of the intima and adventitia, with minimal variation along the aorta. These findings indicate that the media, and to a lesser extent the other layers, have higher resistance to axial tearing compared to circumferential tearing, aligning with the clinical observation of circumferentially directed tears. Intimal and adventitial tear parameters increased modestly along the aorta, while medial parameters varied less, explaining why entry tears rarely originate in the abdominal aorta. Tear parameters in inner and outer quadrants were similar at most axial locations, except for dissimilar tear propagation angles of the intima and adventitia in the proximal aorta (especially the arch), explaining why entry tears seldom involve the entire circumference.</p>","PeriodicalId":54871,"journal":{"name":"Journal of Biomechanical Engineering-Transactions of the Asme","volume":" ","pages":"1-61"},"PeriodicalIF":1.7000,"publicationDate":"2025-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomechanical Engineering-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4067912","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Hemodynamic variations influence the location of entry tears in aortic dissection. This study investigates whether variations in tear strength across the human aorta contribute to these clinical manifestations. Circumferential and axial strips were collected from nine axial and two circumferential sites along each autopsied aorta, yielding 1,188 samples (11 aortas × 18 sites × 2 directions × 3 layers per site). These samples underwent tear testing to assess tear strength and tear energy, constituting resistance to tear propagation. Adventitial tear parameters were significantly higher than those of the intima and media, with no significant differences between the latter two, supporting the observation that entry tears typically occur in the inner wall. Tear propagation angles were approximately 15 and 75 degrees for circumferential and axial medial strips, and 30 and 45 degrees for circumferential and axial strips of the intima and adventitia, with minimal variation along the aorta. These findings indicate that the media, and to a lesser extent the other layers, have higher resistance to axial tearing compared to circumferential tearing, aligning with the clinical observation of circumferentially directed tears. Intimal and adventitial tear parameters increased modestly along the aorta, while medial parameters varied less, explaining why entry tears rarely originate in the abdominal aorta. Tear parameters in inner and outer quadrants were similar at most axial locations, except for dissimilar tear propagation angles of the intima and adventitia in the proximal aorta (especially the arch), explaining why entry tears seldom involve the entire circumference.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.40
自引率
5.90%
发文量
169
审稿时长
4-8 weeks
期刊介绍: Artificial Organs and Prostheses; Bioinstrumentation and Measurements; Bioheat Transfer; Biomaterials; Biomechanics; Bioprocess Engineering; Cellular Mechanics; Design and Control of Biological Systems; Physiological Systems.
期刊最新文献
Biomechanical Analysis for Enhanced Expulsion-Proof Intervertebral Fusion Device. Multiscale Finite Element Modeling of Human Ear for Acoustic Wave Transmission Into Cochlea and Hair Cells Fatigue Failure. Toward a Consistent Framework for Describing the Free Vibration Modes of the Brain. Quantification of Internal Disc Strain Under Dynamic Loading Via High-Frequency Ultrasound. The Influence of Occupant Characteristics, Seat Positioning, and Pre-Crash Maneuvers on Front Passenger Safety Performance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1