Ahsan Hameed, Mario G Ferruzzi, Colin D Kay, D Keith Williams, Elaheh Rahbar, Andrew J Morris
{"title":"Comparison of the capillary and venous blood plasma lipidomes- validation of self-collected blood for plasma lipidomics.","authors":"Ahsan Hameed, Mario G Ferruzzi, Colin D Kay, D Keith Williams, Elaheh Rahbar, Andrew J Morris","doi":"10.1016/j.jlr.2025.100755","DOIUrl":null,"url":null,"abstract":"<p><p>Venipuncture of the upper extremities is commonly used to collect blood for plasma lipidomics. However, self-administered blood collection devices such as the Tasso+<sup>TM</sup> system for capillary blood sampling and plasma separation are convenient and enable frequent sampling without a clinical blood draw. The purpose of this study is to validate Tasso+ sampling for plasma lipidomics by comparing the venous blood and Tasso+ sampled capillary blood plasma lipidomes. Lipids are proven or putative biomarkers of human health and disease and indicators of nutritional and toxicological status. Because exchange of blood components including lipids occurs in capillaries, the capillary and venous blood lipidomes might be different which could confound use of Tasso+ sampled blood as a surrogate for venous blood plasma. Here we compared the lipidomes of Tasso+ drawn capillary blood plasma to venous blood plasma in 10 male subjects using high-resolution mass spectrometry-based lipidomics. While there was substantial inter individual variability between lipidomes, comprehensive statistical approaches with cross validation and multiple testing adjustments showed no difference (adjusted p-value > 0.05) in lipid composition of the paired blood samples. A linear regression model with Spearman correlation analysis also showed a significant-to-near-perfect level (r = 0.95-0.99) of concordance between the samples. Aside from monoacylglycerols (MG) and cardiolipins (CL), every class of lipid was strongly correlated (r = 0.9-0.99) between paired venous and capillary blood plasma. In summary, the capillary and venous blood plasma lipidomes are essentially identical making self-administered collection of capillary blood a viable approach for clinical blood plasma lipidomics.</p>","PeriodicalId":16209,"journal":{"name":"Journal of Lipid Research","volume":" ","pages":"100755"},"PeriodicalIF":5.0000,"publicationDate":"2025-02-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Lipid Research","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1016/j.jlr.2025.100755","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Venipuncture of the upper extremities is commonly used to collect blood for plasma lipidomics. However, self-administered blood collection devices such as the Tasso+TM system for capillary blood sampling and plasma separation are convenient and enable frequent sampling without a clinical blood draw. The purpose of this study is to validate Tasso+ sampling for plasma lipidomics by comparing the venous blood and Tasso+ sampled capillary blood plasma lipidomes. Lipids are proven or putative biomarkers of human health and disease and indicators of nutritional and toxicological status. Because exchange of blood components including lipids occurs in capillaries, the capillary and venous blood lipidomes might be different which could confound use of Tasso+ sampled blood as a surrogate for venous blood plasma. Here we compared the lipidomes of Tasso+ drawn capillary blood plasma to venous blood plasma in 10 male subjects using high-resolution mass spectrometry-based lipidomics. While there was substantial inter individual variability between lipidomes, comprehensive statistical approaches with cross validation and multiple testing adjustments showed no difference (adjusted p-value > 0.05) in lipid composition of the paired blood samples. A linear regression model with Spearman correlation analysis also showed a significant-to-near-perfect level (r = 0.95-0.99) of concordance between the samples. Aside from monoacylglycerols (MG) and cardiolipins (CL), every class of lipid was strongly correlated (r = 0.9-0.99) between paired venous and capillary blood plasma. In summary, the capillary and venous blood plasma lipidomes are essentially identical making self-administered collection of capillary blood a viable approach for clinical blood plasma lipidomics.
期刊介绍:
The Journal of Lipid Research (JLR) publishes original articles and reviews in the broadly defined area of biological lipids. We encourage the submission of manuscripts relating to lipids, including those addressing problems in biochemistry, molecular biology, structural biology, cell biology, genetics, molecular medicine, clinical medicine and metabolism. Major criteria for acceptance of articles are new insights into mechanisms of lipid function and metabolism and/or genes regulating lipid metabolism along with sound primary experimental data. Interpretation of the data is the authors’ responsibility, and speculation should be labeled as such. Manuscripts that provide new ways of purifying, identifying and quantifying lipids are invited for the Methods section of the Journal. JLR encourages contributions from investigators in all countries, but articles must be submitted in clear and concise English.