Clinically Silent Microinfarct Incidence and Risk Factors After Treatment of Unruptured Intracranial Aneurysms with Hydrophilic Polymer-Coated Flow Diverters.

IF 2.6 3区 医学 Q2 CLINICAL NEUROLOGY Clinical Neuroradiology Pub Date : 2025-09-01 Epub Date: 2025-02-14 DOI:10.1007/s00062-025-01497-5
Ali Khanafer, Pablo Albiña-Palmarola, Philipp von Gottberg, Kamran Hajiyev, Sebastian J Müller, Jose E Cohen, Hans Henkes
{"title":"Clinically Silent Microinfarct Incidence and Risk Factors After Treatment of Unruptured Intracranial Aneurysms with Hydrophilic Polymer-Coated Flow Diverters.","authors":"Ali Khanafer, Pablo Albiña-Palmarola, Philipp von Gottberg, Kamran Hajiyev, Sebastian J Müller, Jose E Cohen, Hans Henkes","doi":"10.1007/s00062-025-01497-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Although flow diverters (FDs) revolutionized the treatment of unruptured intracranial aneurysms (UIAs), clinically silent microinfarcts (SMs) are consistently detected in postprocedural diffusion-weighted imaging (DWI), and their clinical consequences remain unknown. This study examined the incidence of, and factors associated with, SM development after the use of two surface-modified FDs: the p48MW-HPC and p64MW-HPC.</p><p><strong>Methods: </strong>A non-concurrent cohort study was conducted in 404 consecutive patients with UIAs treated with these two FDs between January 2020 and July 2023. The primary endpoint was the number of asymptomatic DWI lesions within 72 h after the procedure.</p><p><strong>Results: </strong>SMs were detected in 58.2% of the cases, and ≥ 20 lesions were identified in 7.2% of cases. Multivariate analysis revealed that the use of two specific types of microcatheters-Prowler Select Plus (P < 0.001; IRR, 3.2) and RapidTransit (P = 0.001; IRR, 2.2)-and difficulty in microcatheter navigation to the target vessel (P = 0.039; IRR, 1.8) were significantly associated with greater numbers of lesions. After exclusion of outlier cases, these devices remained associated with a significant 2‑ to 3‑fold increase in SMs. Diabetes was associated with fewer SMs (P = 0.024; IRR, 0.5), although this association disappeared after exclusion of outlier cases.</p><p><strong>Conclusion: </strong>The postprocedural incidence of SMs associated with hydrophilic polymer-coated FDs was similar to that previously reported. Interestingly, the main factor contributing to this phenomenon was the use of certain microcatheters. Careful device selection is crucial, and further research is needed to improve the safety of neurovascular interventions.</p>","PeriodicalId":49298,"journal":{"name":"Clinical Neuroradiology","volume":" ","pages":"459-472"},"PeriodicalIF":2.6000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12454470/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00062-025-01497-5","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/14 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Although flow diverters (FDs) revolutionized the treatment of unruptured intracranial aneurysms (UIAs), clinically silent microinfarcts (SMs) are consistently detected in postprocedural diffusion-weighted imaging (DWI), and their clinical consequences remain unknown. This study examined the incidence of, and factors associated with, SM development after the use of two surface-modified FDs: the p48MW-HPC and p64MW-HPC.

Methods: A non-concurrent cohort study was conducted in 404 consecutive patients with UIAs treated with these two FDs between January 2020 and July 2023. The primary endpoint was the number of asymptomatic DWI lesions within 72 h after the procedure.

Results: SMs were detected in 58.2% of the cases, and ≥ 20 lesions were identified in 7.2% of cases. Multivariate analysis revealed that the use of two specific types of microcatheters-Prowler Select Plus (P < 0.001; IRR, 3.2) and RapidTransit (P = 0.001; IRR, 2.2)-and difficulty in microcatheter navigation to the target vessel (P = 0.039; IRR, 1.8) were significantly associated with greater numbers of lesions. After exclusion of outlier cases, these devices remained associated with a significant 2‑ to 3‑fold increase in SMs. Diabetes was associated with fewer SMs (P = 0.024; IRR, 0.5), although this association disappeared after exclusion of outlier cases.

Conclusion: The postprocedural incidence of SMs associated with hydrophilic polymer-coated FDs was similar to that previously reported. Interestingly, the main factor contributing to this phenomenon was the use of certain microcatheters. Careful device selection is crucial, and further research is needed to improve the safety of neurovascular interventions.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
亲水聚合物包被分流器治疗未破裂颅内动脉瘤后临床无症状微梗死发生率及危险因素
目的:尽管血流分流器(fd)彻底改变了未破裂颅内动脉瘤(UIAs)的治疗方法,但术后弥散加权成像(DWI)经常检测到临床无症状的微梗死(SMs),其临床后果尚不清楚。本研究考察了使用两种表面改性fd (p48MW-HPC和p64MW-HPC)后SM发生的发生率及其相关因素。方法:在2020年1月至2023年7月期间,对404例连续接受这两种fd治疗的UIAs患者进行了一项非并发队列研究。主要终点是术后72小时内无症状DWI病变的数量 h。结果:58.2%的病例检出SMs, 7.2%的病例检出≥ 20个病变。多变量分析显示,两种特定类型的微导管的使用- prowler Select Plus (P )结论:与亲水性聚合物包被fd相关的术后SMs发生率与先前报道相似。有趣的是,造成这种现象的主要因素是某些微导管的使用。谨慎的设备选择是至关重要的,需要进一步的研究来提高神经血管干预的安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Clinical Neuroradiology
Clinical Neuroradiology CLINICAL NEUROLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
5.00
自引率
3.60%
发文量
106
审稿时长
>12 weeks
期刊介绍: Clinical Neuroradiology provides current information, original contributions, and reviews in the field of neuroradiology. An interdisciplinary approach is accomplished by diagnostic and therapeutic contributions related to associated subjects. The international coverage and relevance of the journal is underlined by its being the official journal of the German, Swiss, and Austrian Societies of Neuroradiology.
期刊最新文献
Rethinking the Role of CT Perfusion in IVT Decision-Making in Acute Ischemic Stroke. Thrombolysis in Cerebral Infarction (TICI) 2b Versus TICI 3 Reperfusion in Stroke Patients with Mild Symptoms. Association Between Occluded Vessel Diameter and Clinical Outcomes of Mechanical Thrombectomy for M2 Occlusion. Mid- and Long-Term Outcomes Following Flow Diversion for Carotid-Ophthalmic Aneurysms: a Single-Centre Experience. A Bail out Technique to Manage Cervical Artery Dissections During Neurointerventions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1