Minimizing Variable Downhole Fractionation in U–Pb Zircon Geochronology by LA-MC-ICP-MS at Smaller Spot Size

IF 1.9 3区 化学 Q3 BIOCHEMICAL RESEARCH METHODS Journal of Mass Spectrometry Pub Date : 2025-02-18 DOI:10.1002/jms.5115
Saurabh Singhal, Sandeep Singh, Dharmendra Singh
{"title":"Minimizing Variable Downhole Fractionation in U–Pb Zircon Geochronology by LA-MC-ICP-MS at Smaller Spot Size","authors":"Saurabh Singhal,&nbsp;Sandeep Singh,&nbsp;Dharmendra Singh","doi":"10.1002/jms.5115","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>The development of LA-ICPMS and LA-MC-ICPMS resulted in analytical methods for zircon geochronology using a 20- to 60-μm laser spot size. A high amount of complexly zoned zircons promotes the requirement of U–Pb dating at smaller spot sizes. When spot size reduces, downhole fractionation (DHF) increases, increasing the DHF discrepancy between zircon grains and the primary reference zircon standard and resulting in inaccurate results. With MC-ICPMS's high sensitivity and multi-collector capabilities, this work attempts to accurately determine age with spatial resolutions below 20 μm. Three well-characterized zircon standards (91500, GJ-1, and Plešovice) were tested at spot sizes of 35, 20, 15, and 10 μm. Laser and mass spectrometry tuning, laser shot count, and ablation time have been optimized to reduce the DHF effect on measurement accuracy. Static ablation of 35- to 15-μm spots with 150 laser shot counts (30 s) yielded precision of less than 1.5% and age offset of less than 2%. The DHF differs significantly from the reference standard and two test zircon samples used for validation, with an age offset of 4% at 10-μm spot sizes. Masking shot counts from the end enhanced accuracy, notably for lower laser shot counts and shorter ablation times. At 75 laser shot counts, precision reached 1.4% and age offsets reduced to 1.6% for <sup>206</sup>Pb/<sup>238</sup>U age. This method minimizes laser shot counts to avoid sampling two age groups. Higher zircon DHF variability at smaller spot sizes may influence a well-calibrated, sensitive LA-MC-ICP-MS analytical figure of merit.</p>\n </div>","PeriodicalId":16178,"journal":{"name":"Journal of Mass Spectrometry","volume":"60 3","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2025-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jms.5115","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

The development of LA-ICPMS and LA-MC-ICPMS resulted in analytical methods for zircon geochronology using a 20- to 60-μm laser spot size. A high amount of complexly zoned zircons promotes the requirement of U–Pb dating at smaller spot sizes. When spot size reduces, downhole fractionation (DHF) increases, increasing the DHF discrepancy between zircon grains and the primary reference zircon standard and resulting in inaccurate results. With MC-ICPMS's high sensitivity and multi-collector capabilities, this work attempts to accurately determine age with spatial resolutions below 20 μm. Three well-characterized zircon standards (91500, GJ-1, and Plešovice) were tested at spot sizes of 35, 20, 15, and 10 μm. Laser and mass spectrometry tuning, laser shot count, and ablation time have been optimized to reduce the DHF effect on measurement accuracy. Static ablation of 35- to 15-μm spots with 150 laser shot counts (30 s) yielded precision of less than 1.5% and age offset of less than 2%. The DHF differs significantly from the reference standard and two test zircon samples used for validation, with an age offset of 4% at 10-μm spot sizes. Masking shot counts from the end enhanced accuracy, notably for lower laser shot counts and shorter ablation times. At 75 laser shot counts, precision reached 1.4% and age offsets reduced to 1.6% for 206Pb/238U age. This method minimizes laser shot counts to avoid sampling two age groups. Higher zircon DHF variability at smaller spot sizes may influence a well-calibrated, sensitive LA-MC-ICP-MS analytical figure of merit.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
相关文献
The determinants of transnational entrepreneurship and transnational ties’ dynamics among immigrant entrepreneurs in ICT sector in Italy
IF 1.9 3区 社会学International MigrationPub Date : 2017-04-05 DOI: 10.1111/imig.12335
Jan Brzozowski, Marco Cucculelli, Aleksander Surdej
来源期刊
Journal of Mass Spectrometry
Journal of Mass Spectrometry 化学-光谱学
CiteScore
5.10
自引率
0.00%
发文量
84
审稿时长
1.5 months
期刊介绍: The Journal of Mass Spectrometry publishes papers on a broad range of topics of interest to scientists working in both fundamental and applied areas involving the study of gaseous ions. The aim of JMS is to serve the scientific community with information provided and arranged to help senior investigators to better stay abreast of new discoveries and studies in their own field, to make them aware of events and developments in associated fields, and to provide students and newcomers the basic tools with which to learn fundamental and applied aspects of mass spectrometry.
期刊最新文献
Issue Information Detection and Behaviors of TEMPO Derivatives in Seven Mass Spectrometry Ionization Methods Development of an LC–MS/MS Method for Quantifying Occidiofungin in Rabbit Plasma In Vitro and In Vivo Assessment of Antidiabetic Activity of Cupressus torulosa D. Don Needles, Their LCQTOFMS Assisted Metabolite Profiling, and Implications for Diabetes Management Mass Spectrometry–Based Proteomics in Clinical Diagnosis of Amyloidosis and Multiple Myeloma: A Review (2012–2024)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.