A Fully Validated LC-QTOF-MS Screening Workflow for the Analysis of Drugs in Oral Fluid.

IF 2.3 3区 医学 Q3 CHEMISTRY, ANALYTICAL Journal of analytical toxicology Pub Date : 2025-02-17 DOI:10.1093/jat/bkaf013
Cynthia Coulter, Jonah Gonzales, Campbell A Coulter, Jarrad Wagner, Christine Moore
{"title":"A Fully Validated LC-QTOF-MS Screening Workflow for the Analysis of Drugs in Oral Fluid.","authors":"Cynthia Coulter, Jonah Gonzales, Campbell A Coulter, Jarrad Wagner, Christine Moore","doi":"10.1093/jat/bkaf013","DOIUrl":null,"url":null,"abstract":"<p><p>A simple liquid-liquid extraction procedure (LLE) followed by liquid chromatography quadrupole time of flight tandem mass spectrometry (LC-QTOF-MS) analysis for drugs in oral fluid collected with the Quantisal™ device has been developed. The decision point cut-off concentrations were at or below those recommended by the National Safety Council's Alcohol, Drugs, and Impairment Division (NSC-ADID) for toxicological investigation of driving under the influence of drugs cases (DUID). Currently ANSI/ASB standard 120 does not cover the analysis of oral fluid collected in impaired driving investigations, instead guidance from the NSC-ADID was used. The supporting mass spectral based screening library was adapted from commercially available databases and included Tier 1 and Tier 2 recommended compounds. Further, the additional inclusion of novel psychoactive substances and synthetic cannabinoids was based on the Center for Forensic Science Research and Education's (CFSRE) quarterly publications of 2023. Metabolites from those publications were not included in this method since, with some exceptions, parent drugs are the dominant compounds in oral fluid. Briefly, Quantisal™ (1mL) was mixed with organic solvents, centrifuged, and decanted; followed by a second liquid-liquid process which extracted all the drugs in a single aliquot. A gradient liquid chromatography program using 0.1% formic acid in water and 0.1% formic acid in methanol was used and the runtime was 10 minutes. LC-QTOF-MS settings were optimized to promote greater sensitivity for a wide range of drug classes. The method was fully validated using ANSI/ASB 036 Standard Practices for Method Validation in Forensic Toxicology as guidance. Interference studies, limit of detection, precision at and around the decision points, ionization suppression/enhancement, and processed sample stability up to 96 hours were completed for each drug in the library database. While ion suppression or enhancement of the analytes varied greatly, the decision point was not significantly affected and internal standards that mimicked similar responses were chosen for each analyte. The method was applied to proficiency program samples, routine samples received into the laboratory, and blind samples screened against the search engine. The optimization of specific tune characteristics and instrument settings allowed the user to meet or exceed recommended screening limits for drugs in Quantisal™ collected oral fluid samples without the need for immunoassay testing.</p>","PeriodicalId":14905,"journal":{"name":"Journal of analytical toxicology","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of analytical toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/jat/bkaf013","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

A simple liquid-liquid extraction procedure (LLE) followed by liquid chromatography quadrupole time of flight tandem mass spectrometry (LC-QTOF-MS) analysis for drugs in oral fluid collected with the Quantisal™ device has been developed. The decision point cut-off concentrations were at or below those recommended by the National Safety Council's Alcohol, Drugs, and Impairment Division (NSC-ADID) for toxicological investigation of driving under the influence of drugs cases (DUID). Currently ANSI/ASB standard 120 does not cover the analysis of oral fluid collected in impaired driving investigations, instead guidance from the NSC-ADID was used. The supporting mass spectral based screening library was adapted from commercially available databases and included Tier 1 and Tier 2 recommended compounds. Further, the additional inclusion of novel psychoactive substances and synthetic cannabinoids was based on the Center for Forensic Science Research and Education's (CFSRE) quarterly publications of 2023. Metabolites from those publications were not included in this method since, with some exceptions, parent drugs are the dominant compounds in oral fluid. Briefly, Quantisal™ (1mL) was mixed with organic solvents, centrifuged, and decanted; followed by a second liquid-liquid process which extracted all the drugs in a single aliquot. A gradient liquid chromatography program using 0.1% formic acid in water and 0.1% formic acid in methanol was used and the runtime was 10 minutes. LC-QTOF-MS settings were optimized to promote greater sensitivity for a wide range of drug classes. The method was fully validated using ANSI/ASB 036 Standard Practices for Method Validation in Forensic Toxicology as guidance. Interference studies, limit of detection, precision at and around the decision points, ionization suppression/enhancement, and processed sample stability up to 96 hours were completed for each drug in the library database. While ion suppression or enhancement of the analytes varied greatly, the decision point was not significantly affected and internal standards that mimicked similar responses were chosen for each analyte. The method was applied to proficiency program samples, routine samples received into the laboratory, and blind samples screened against the search engine. The optimization of specific tune characteristics and instrument settings allowed the user to meet or exceed recommended screening limits for drugs in Quantisal™ collected oral fluid samples without the need for immunoassay testing.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.10
自引率
20.00%
发文量
92
审稿时长
6-12 weeks
期刊介绍: The Journal of Analytical Toxicology (JAT) is an international toxicology journal devoted to the timely dissemination of scientific communications concerning potentially toxic substances and drug identification, isolation, and quantitation. Since its inception in 1977, the Journal of Analytical Toxicology has striven to present state-of-the-art techniques used in toxicology labs. The peer-review process provided by the distinguished members of the Editorial Advisory Board ensures the high-quality and integrity of articles published in the Journal of Analytical Toxicology. Timely presentation of the latest toxicology developments is ensured through Technical Notes, Case Reports, and Letters to the Editor.
期刊最新文献
A Fully Validated LC-QTOF-MS Screening Workflow for the Analysis of Drugs in Oral Fluid. Double designers: detection of bromazolam and metonitazene in postmortem casework. Postmortem diphenhydramine blood concentrations in children. Optimization of a disposable pipette tips extraction for the analysis of psychoactive substances in sweat specimens using design of experiments. LC-MS-MS confirmation of 11-nor-9-carboxy-tetrahydrocannabinol (Δ8, Δ9, Δ10) and hexahydrocannabinol metabolites in authentic urine specimens.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1