Significance of waste discharge concentration on the fluid flow over a squeezing porous slider: solution by improved residual power series method

IF 1.9 4区 物理与天体物理 Q2 PHYSICS, MULTIDISCIPLINARY Pramana Pub Date : 2025-02-20 DOI:10.1007/s12043-024-02874-4
M C Jayaprakash, T Ramachandran, Ambati Vijay Kumar, Vikas Kaushik, Sanjeev Kumar Joshi, A S Siddesh, Nehad Ali Shah, J Rekha
{"title":"Significance of waste discharge concentration on the fluid flow over a squeezing porous slider: solution by improved residual power series method","authors":"M C Jayaprakash,&nbsp;T Ramachandran,&nbsp;Ambati Vijay Kumar,&nbsp;Vikas Kaushik,&nbsp;Sanjeev Kumar Joshi,&nbsp;A S Siddesh,&nbsp;Nehad Ali Shah,&nbsp;J Rekha","doi":"10.1007/s12043-024-02874-4","DOIUrl":null,"url":null,"abstract":"<div><p>The current analysis focusses on the three-dimensional viscous flow caused by an expanding or contracting porous slider under the impact of heat source<span>\\(/\\)</span>sink, magnetic field and waste discharge concentration. The amount of fluid injected to levitate the slider is not constant; rather, it varies over time based on the slider's location at any given moment. The fluid flow between the ground and the slider is represented by the unsteady nonlinear equations of motion, which are converted into ordinary differential equations by employing the apt similarity transformations. These simplified equations are solved by applying the hybrid residual power series method (HRPSM). Using graphical representations, the physical behaviour of significant parameters is investigated. Tabular data are used to compare the hybrid residual power series method and the numerical scheme to check the convergence and accuracy of the hybrid residual power series method. A rise in the magnetic parameter results in a very modest rise in the fluid's longitudinal velocity in the regions closest to the upper or lower plates and a clear drop in the liquid's longitudinal velocity in the centre region. An increase in pollutant external-source parameter increases the amount of pollutants introduced into the fluid system.</p></div>","PeriodicalId":743,"journal":{"name":"Pramana","volume":"99 1","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2025-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s12043-024-02874-4.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pramana","FirstCategoryId":"4","ListUrlMain":"https://link.springer.com/article/10.1007/s12043-024-02874-4","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PHYSICS, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

The current analysis focusses on the three-dimensional viscous flow caused by an expanding or contracting porous slider under the impact of heat source\(/\)sink, magnetic field and waste discharge concentration. The amount of fluid injected to levitate the slider is not constant; rather, it varies over time based on the slider's location at any given moment. The fluid flow between the ground and the slider is represented by the unsteady nonlinear equations of motion, which are converted into ordinary differential equations by employing the apt similarity transformations. These simplified equations are solved by applying the hybrid residual power series method (HRPSM). Using graphical representations, the physical behaviour of significant parameters is investigated. Tabular data are used to compare the hybrid residual power series method and the numerical scheme to check the convergence and accuracy of the hybrid residual power series method. A rise in the magnetic parameter results in a very modest rise in the fluid's longitudinal velocity in the regions closest to the upper or lower plates and a clear drop in the liquid's longitudinal velocity in the centre region. An increase in pollutant external-source parameter increases the amount of pollutants introduced into the fluid system.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Pramana
Pramana 物理-物理:综合
CiteScore
3.60
自引率
7.10%
发文量
206
审稿时长
3 months
期刊介绍: Pramana - Journal of Physics is a monthly research journal in English published by the Indian Academy of Sciences in collaboration with Indian National Science Academy and Indian Physics Association. The journal publishes refereed papers covering current research in Physics, both original contributions - research papers, brief reports or rapid communications - and invited reviews. Pramana also publishes special issues devoted to advances in specific areas of Physics and proceedings of select high quality conferences.
期刊最新文献
Enhanced UV and IR filtering with PMMA\(/\)perylene-coated FTO glass for energy-efficient luminescent solar concentrator windows Viscous damping of r-modes and emission of gravitational waves Significance of waste discharge concentration on the fluid flow over a squeezing porous slider: solution by improved residual power series method Projective exponential anti-synchronisation of space–time discrete Lur’e oscillator networks with uncertain Markov jumps Negative frequencies in the scattering properties of parity–time symmetry and anti-parity–time symmetry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1