Sane Approach to Optimizing the Workload in Remote Monitoring of Cardiovascular Implantable Electronic Devices.

IF 9.1 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS Circulation. Arrhythmia and electrophysiology Pub Date : 2025-02-20 DOI:10.1161/CIRCEP.124.013078
Markus Sane, Toni Jäntti, Annukka Marjamaa, Elina Pennanen, Charlotte Aura, Eeva Torvinen, Leena Karjalainen, Pekka Raatikainen, Jarkko Karvonen
{"title":"Sane Approach to Optimizing the Workload in Remote Monitoring of Cardiovascular Implantable Electronic Devices.","authors":"Markus Sane, Toni Jäntti, Annukka Marjamaa, Elina Pennanen, Charlotte Aura, Eeva Torvinen, Leena Karjalainen, Pekka Raatikainen, Jarkko Karvonen","doi":"10.1161/CIRCEP.124.013078","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Remote monitoring offers an effective and safe method for monitoring patients with cardiovascular implantable electronic devices. The downside of remote monitoring is the overflow of the data. Since many of the remote monitoring transmissions are nonactionable, optimizing alert transmissions could partly overcome this problem.</p><p><strong>Methods: </strong>We collected data on the number and the causes of all alert-, scheduled-, and patient-initiated transmissions as well as actions initiated by these transmissions in 2023. According to our strategy, all clinically nonrelevant alerts were turned off. The trend of alert transmissions and the proportion of actionable scheduled transmissions are presented. The patient safety was monitored by analyzing the premortem alerts and changes to alert settings in deceased patients, as well as the rate of actionable scheduled or patient-initiated transmissions during follow-up.</p><p><strong>Results: </strong>During the study period 8182 transmissions were generated from 3732 cardiovascular implantable electronic devices. Of these, 2306 (28%) were alert transmissions, of which 57% (n=1290) were considered clinically nonrelevant. The rate of alerts decreased by 44% from January to December (0.07 versus 0.04 per device per month, <i>P</i>=0.001). Of the 3335 scheduled transmissions, 11% (364) were actionable, and the proportion of actionable scheduled transmissions remained unchanged during the follow-up period (<i>P</i>=0.08). Notably, none of the deaths were linked to the adjustment of alert settings.</p><p><strong>Conclusions: </strong>Our data indicated that active evaluation of the clinical relevance of all alert transmissions and deactivation of clinically nonrelevant alerts reduce the remote monitoring workload. However, long-term follow-up is needed to ensure that patient safety is not compromised.</p>","PeriodicalId":10319,"journal":{"name":"Circulation. Arrhythmia and electrophysiology","volume":" ","pages":"e013078"},"PeriodicalIF":9.1000,"publicationDate":"2025-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation. Arrhythmia and electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1161/CIRCEP.124.013078","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Remote monitoring offers an effective and safe method for monitoring patients with cardiovascular implantable electronic devices. The downside of remote monitoring is the overflow of the data. Since many of the remote monitoring transmissions are nonactionable, optimizing alert transmissions could partly overcome this problem.

Methods: We collected data on the number and the causes of all alert-, scheduled-, and patient-initiated transmissions as well as actions initiated by these transmissions in 2023. According to our strategy, all clinically nonrelevant alerts were turned off. The trend of alert transmissions and the proportion of actionable scheduled transmissions are presented. The patient safety was monitored by analyzing the premortem alerts and changes to alert settings in deceased patients, as well as the rate of actionable scheduled or patient-initiated transmissions during follow-up.

Results: During the study period 8182 transmissions were generated from 3732 cardiovascular implantable electronic devices. Of these, 2306 (28%) were alert transmissions, of which 57% (n=1290) were considered clinically nonrelevant. The rate of alerts decreased by 44% from January to December (0.07 versus 0.04 per device per month, P=0.001). Of the 3335 scheduled transmissions, 11% (364) were actionable, and the proportion of actionable scheduled transmissions remained unchanged during the follow-up period (P=0.08). Notably, none of the deaths were linked to the adjustment of alert settings.

Conclusions: Our data indicated that active evaluation of the clinical relevance of all alert transmissions and deactivation of clinically nonrelevant alerts reduce the remote monitoring workload. However, long-term follow-up is needed to ensure that patient safety is not compromised.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
13.70
自引率
4.80%
发文量
187
审稿时长
4-8 weeks
期刊介绍: Circulation: Arrhythmia and Electrophysiology is a journal dedicated to the study and application of clinical cardiac electrophysiology. It covers a wide range of topics including the diagnosis and treatment of cardiac arrhythmias, as well as research in this field. The journal accepts various types of studies, including observational research, clinical trials, epidemiological studies, and advancements in translational research.
期刊最新文献
Characteristics of Patients With the Arrhythmogenic Mitral Valve Prolapse Syndrome and Sudden Cardiac Arrest and Sustained Ventricular Arrhythmias. Independent External Evaluation of Pediatric Hypertrophic Cardiomyopathy Risk Scores in Predicting Severe Ventricular Arrhythmias. Sane Approach to Optimizing the Workload in Remote Monitoring of Cardiovascular Implantable Electronic Devices. Blanking Period After Catheter Ablation of Paroxysmal Atrial Fibrillation: Insights From Continuous Cardiac Monitoring. In Vivo Endocardial and Epicardial Mapping of Human Sinus Node: From Electrical Landmarks to Anatomical Landmarks.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1