Lotte M J Scheres, Stefani Kujovic-Aleksov, Bjorn Winkens, Ronald M P C de Crom, Carroll A B Webers, Henny J M Beckers
{"title":"Five-year follow-up with the PreserFlo MicroShunt for open-angle glaucoma.","authors":"Lotte M J Scheres, Stefani Kujovic-Aleksov, Bjorn Winkens, Ronald M P C de Crom, Carroll A B Webers, Henny J M Beckers","doi":"10.1038/s41433-025-03707-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To report on five-year results with the PreserFlo MicroShunt (MicroShunt) for the surgical treatment of open-angle glaucoma.</p><p><strong>Patients and methods: </strong>Retrospective case series of consecutive patients who underwent a stand-alone MicroShunt implantation at the University Eye Clinic of Maastricht. If a patient underwent the procedure in both eyes, only the first eye was included in the analysis. MicroShunt implantation was augmented with 0.2 mg/ml mitomycin-C. The primary outcome was intraocular pressure (IOP) during follow-up. Furthermore, information on IOP-lowering medication use, success rates, reoperation rates, and postoperative complications was collected.</p><p><strong>Results: </strong>Sixty-six eyes were included for analyses. Diagnoses included primary open-angle glaucoma (88%) and pigmentary glaucoma (12%). The majority of patients had moderate or advanced glaucoma, based on the mean deviation of the visual field examination. Mean (95% - confidence interval) IOP dropped from 21.8 (20.8-22.8) at baseline to 13.2 (11.8-14.6) mmHg after 5 years (p < 0.001). Mean number of IOP-lowering medications was reduced from 2.5 (2.2-2.9) at baseline to 0.9 (0.5-1.2), 1.0 (0.7-1.4), and 1.1 (0.7-1.5) after three, four, and five years (all p < 0.001). Needling or surgical revision was performed in twelve eyes (18%). Nineteen eyes (29%) required further IOP-lowering surgery. Postoperative complications were usually mild and self-limiting and included early hypotony, shallow anterior chamber, and hyphaema.</p><p><strong>Conclusions: </strong>After five years, the MicroShunt was found to be a safe procedure, leading to a sustained reduction in mean IOP and number of IOP-lowering medications. However, almost one third of the eyes required further IOP-lowering interventions.</p>","PeriodicalId":12125,"journal":{"name":"Eye","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2025-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1038/s41433-025-03707-3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To report on five-year results with the PreserFlo MicroShunt (MicroShunt) for the surgical treatment of open-angle glaucoma.
Patients and methods: Retrospective case series of consecutive patients who underwent a stand-alone MicroShunt implantation at the University Eye Clinic of Maastricht. If a patient underwent the procedure in both eyes, only the first eye was included in the analysis. MicroShunt implantation was augmented with 0.2 mg/ml mitomycin-C. The primary outcome was intraocular pressure (IOP) during follow-up. Furthermore, information on IOP-lowering medication use, success rates, reoperation rates, and postoperative complications was collected.
Results: Sixty-six eyes were included for analyses. Diagnoses included primary open-angle glaucoma (88%) and pigmentary glaucoma (12%). The majority of patients had moderate or advanced glaucoma, based on the mean deviation of the visual field examination. Mean (95% - confidence interval) IOP dropped from 21.8 (20.8-22.8) at baseline to 13.2 (11.8-14.6) mmHg after 5 years (p < 0.001). Mean number of IOP-lowering medications was reduced from 2.5 (2.2-2.9) at baseline to 0.9 (0.5-1.2), 1.0 (0.7-1.4), and 1.1 (0.7-1.5) after three, four, and five years (all p < 0.001). Needling or surgical revision was performed in twelve eyes (18%). Nineteen eyes (29%) required further IOP-lowering surgery. Postoperative complications were usually mild and self-limiting and included early hypotony, shallow anterior chamber, and hyphaema.
Conclusions: After five years, the MicroShunt was found to be a safe procedure, leading to a sustained reduction in mean IOP and number of IOP-lowering medications. However, almost one third of the eyes required further IOP-lowering interventions.
期刊介绍:
Eye seeks to provide the international practising ophthalmologist with high quality articles, of academic rigour, on the latest global clinical and laboratory based research. Its core aim is to advance the science and practice of ophthalmology with the latest clinical- and scientific-based research. Whilst principally aimed at the practising clinician, the journal contains material of interest to a wider readership including optometrists, orthoptists, other health care professionals and research workers in all aspects of the field of visual science worldwide. Eye is the official journal of The Royal College of Ophthalmologists.
Eye encourages the submission of original articles covering all aspects of ophthalmology including: external eye disease; oculo-plastic surgery; orbital and lacrimal disease; ocular surface and corneal disorders; paediatric ophthalmology and strabismus; glaucoma; medical and surgical retina; neuro-ophthalmology; cataract and refractive surgery; ocular oncology; ophthalmic pathology; ophthalmic genetics.