{"title":"Assessing the rigidity of thermoplastic masks for head immobilization effectiveness in stereotactic radiosurgery.","authors":"Iris Pasion Apale, Adam Agnew, Daniel Foley","doi":"10.1002/acm2.70058","DOIUrl":null,"url":null,"abstract":"<p><p>This study compared three Brainlab thermoplastic masks-Cranial 4pi basic, stereotactic (Close Mask V2), and open-face-to see how well they limited head movement during Stereotactic Radiosurgery (SRS). Using a head phantom, we tested rotational movements (pitch, yaw, and roll) and measured displacements with the ExacTrac system. The open-face mask had the smallest mean displacements (pitch: 0.14 ± 0.03°, yaw: 0.11 ± 0.02°, roll: 0.16 ± 0.03°) and performed slightly better than the stereotactic mask in pitch (0.20 ± 0.04°, p = 0.0173). The stereotactic mask performed similarly in yaw (0.09 ± 0.02°) and roll (0.16 ± 0.04°). The basic mask showed much more movement (pitch: 0.44 ± 0.13°, yaw: 0.28 ± 0.07°, roll: 0.26 ± 0.07°), making it less suitable for SRS. These results apply to the solid two-piece masks tested here and show that both the open-face and stereotactic masks provide reliable immobilization for accurate SRS treatments.</p>","PeriodicalId":14989,"journal":{"name":"Journal of Applied Clinical Medical Physics","volume":" ","pages":"e70058"},"PeriodicalIF":2.0000,"publicationDate":"2025-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Clinical Medical Physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/acm2.70058","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
This study compared three Brainlab thermoplastic masks-Cranial 4pi basic, stereotactic (Close Mask V2), and open-face-to see how well they limited head movement during Stereotactic Radiosurgery (SRS). Using a head phantom, we tested rotational movements (pitch, yaw, and roll) and measured displacements with the ExacTrac system. The open-face mask had the smallest mean displacements (pitch: 0.14 ± 0.03°, yaw: 0.11 ± 0.02°, roll: 0.16 ± 0.03°) and performed slightly better than the stereotactic mask in pitch (0.20 ± 0.04°, p = 0.0173). The stereotactic mask performed similarly in yaw (0.09 ± 0.02°) and roll (0.16 ± 0.04°). The basic mask showed much more movement (pitch: 0.44 ± 0.13°, yaw: 0.28 ± 0.07°, roll: 0.26 ± 0.07°), making it less suitable for SRS. These results apply to the solid two-piece masks tested here and show that both the open-face and stereotactic masks provide reliable immobilization for accurate SRS treatments.
期刊介绍:
Journal of Applied Clinical Medical Physics is an international Open Access publication dedicated to clinical medical physics. JACMP welcomes original contributions dealing with all aspects of medical physics from scientists working in the clinical medical physics around the world. JACMP accepts only online submission.
JACMP will publish:
-Original Contributions: Peer-reviewed, investigations that represent new and significant contributions to the field. Recommended word count: up to 7500.
-Review Articles: Reviews of major areas or sub-areas in the field of clinical medical physics. These articles may be of any length and are peer reviewed.
-Technical Notes: These should be no longer than 3000 words, including key references.
-Letters to the Editor: Comments on papers published in JACMP or on any other matters of interest to clinical medical physics. These should not be more than 1250 (including the literature) and their publication is only based on the decision of the editor, who occasionally asks experts on the merit of the contents.
-Book Reviews: The editorial office solicits Book Reviews.
-Announcements of Forthcoming Meetings: The Editor may provide notice of forthcoming meetings, course offerings, and other events relevant to clinical medical physics.
-Parallel Opposed Editorial: We welcome topics relevant to clinical practice and medical physics profession. The contents can be controversial debate or opposed aspects of an issue. One author argues for the position and the other against. Each side of the debate contains an opening statement up to 800 words, followed by a rebuttal up to 500 words. Readers interested in participating in this series should contact the moderator with a proposed title and a short description of the topic