How to Avoid Arterial Access During Transcatheter Closure of Patent Ductus Arteriosus Using Anatomo-haemodynamic Landmark.

IF 0.7 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of the Saudi Heart Association Pub Date : 2025-01-26 eCollection Date: 2025-01-01 DOI:10.37616/2212-5043.1415
Mohit Sachan, Kumar Himanshu, Mukesh J Jha, Santosh K Sinha, Mahmodullah Razi, Awadhesh K Sharma, Puneet Aggarwal, Praveen Shukla, Umeshwar Pandey, Rakesh Verma
{"title":"How to Avoid Arterial Access During Transcatheter Closure of Patent Ductus Arteriosus Using Anatomo-haemodynamic Landmark.","authors":"Mohit Sachan, Kumar Himanshu, Mukesh J Jha, Santosh K Sinha, Mahmodullah Razi, Awadhesh K Sharma, Puneet Aggarwal, Praveen Shukla, Umeshwar Pandey, Rakesh Verma","doi":"10.37616/2212-5043.1415","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the feasibility, safety, and efficacy of transcatheter closure (TCC) of patent ductus arteriosus (PDA) using anatomo-haemodynamic landmark without any arteriography.</p><p><strong>Method: </strong>In this prospective, non-randomized study, all consecutive patients with PDA undergoing transcatheter closure at LPS Institute of Cardiology, Kanpur, India between January 2019 and June 2024 were evaluated. TCC was performed using anatomical and haemodynamicl landmark without aortogram, and device was deployed through antegrade route only. Transthoracic echocardiography with colour-Doppler imaging was used to confirm position of the device before final deployment. Primary outcome was procedural and fluoroscopy time, and major complications (access site complications, device embolization, residual shunt ≥ grade 3, haemolysis, flow acceleration in left pulmonary artery and descending thoracic aorta, and death). Success was defined as complete closure of shunt without any major complications.</p><p><strong>Result: </strong>TCC was successfully performed through antegrade route in 250 patients (age: 2.3 ± 1.2 years; weight: 10.3 ± 9.8 kg) while 16 patients were excluded for various reasons. Mean diameter of duct was 6.7 ± 4.5 mm. Male and female comprised 176 (70.4%) and 74 (29.6%) respectively. PDA were type A (n = 195; 78%), B (n = 27; 10.8%), C (n = 20; 8%), and (n = 8; 3.2%). TCC was successful in all patients although dislodgement was noted in 1 (0.04%). Lifetech duct occluder and Konar MFO were most commonly used devices in 156 (62.4%) and 33 (13.2%) patients respectively. Immediate closure was achieved in 233 (93.2%) patients while remaining 17 (7.8%) with grade I or II shunt on echocardiogram had complete closure in 2 days. Device embolization was observed in 1 (0.4%) patient while flow acceleration in DTA were observed in 5 (2%) patients. Procedure was successful in 99.6% using antegrade while TCC using isolated venous route was successful in 94%.</p><p><strong>Conclusion: </strong>TCC of PDA using anatomo-haemodynamic landmark and avoiding arterial access is feasible, safe, and effective, with excellent results on short and medium-term follow-up.</p>","PeriodicalId":17319,"journal":{"name":"Journal of the Saudi Heart Association","volume":"37 1","pages":"5"},"PeriodicalIF":0.7000,"publicationDate":"2025-01-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11839175/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Saudi Heart Association","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37616/2212-5043.1415","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate the feasibility, safety, and efficacy of transcatheter closure (TCC) of patent ductus arteriosus (PDA) using anatomo-haemodynamic landmark without any arteriography.

Method: In this prospective, non-randomized study, all consecutive patients with PDA undergoing transcatheter closure at LPS Institute of Cardiology, Kanpur, India between January 2019 and June 2024 were evaluated. TCC was performed using anatomical and haemodynamicl landmark without aortogram, and device was deployed through antegrade route only. Transthoracic echocardiography with colour-Doppler imaging was used to confirm position of the device before final deployment. Primary outcome was procedural and fluoroscopy time, and major complications (access site complications, device embolization, residual shunt ≥ grade 3, haemolysis, flow acceleration in left pulmonary artery and descending thoracic aorta, and death). Success was defined as complete closure of shunt without any major complications.

Result: TCC was successfully performed through antegrade route in 250 patients (age: 2.3 ± 1.2 years; weight: 10.3 ± 9.8 kg) while 16 patients were excluded for various reasons. Mean diameter of duct was 6.7 ± 4.5 mm. Male and female comprised 176 (70.4%) and 74 (29.6%) respectively. PDA were type A (n = 195; 78%), B (n = 27; 10.8%), C (n = 20; 8%), and (n = 8; 3.2%). TCC was successful in all patients although dislodgement was noted in 1 (0.04%). Lifetech duct occluder and Konar MFO were most commonly used devices in 156 (62.4%) and 33 (13.2%) patients respectively. Immediate closure was achieved in 233 (93.2%) patients while remaining 17 (7.8%) with grade I or II shunt on echocardiogram had complete closure in 2 days. Device embolization was observed in 1 (0.4%) patient while flow acceleration in DTA were observed in 5 (2%) patients. Procedure was successful in 99.6% using antegrade while TCC using isolated venous route was successful in 94%.

Conclusion: TCC of PDA using anatomo-haemodynamic landmark and avoiding arterial access is feasible, safe, and effective, with excellent results on short and medium-term follow-up.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of the Saudi Heart Association
Journal of the Saudi Heart Association CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
1.40
自引率
0.00%
发文量
30
审稿时长
15 weeks
期刊最新文献
Effectiveness of Empagliflozin in Treating Patients With Heart Failure With Preserved Ejection Fraction: A Systematic Review. The Safety of Ramadan Fasting in Chronic Heart Failure Patients With Reduced Ejection Fraction. Challenges in Diagnosing and Treating Fungal Endocarditis: A Case Report of Recurrent Candida Endocarditis in a Hemodialysis Patient. How to Avoid Arterial Access During Transcatheter Closure of Patent Ductus Arteriosus Using Anatomo-haemodynamic Landmark. The Usefulness of 3D Heart Models as a Tool of Congenital Heart Disease Education: A Narrative Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1