Serum and Urine Gadolinium Reference Intervals in Patients With Normal Renal Function Following Gadobutrol Administration.

IF 7 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Investigative Radiology Pub Date : 2025-02-24 DOI:10.1097/RLI.0000000000001165
Jennifer S McDonald, Patrick L Day, Grant M Spears, Joshua A Bornhorst, Robert J McDonald, Paul J Jannetto
{"title":"Serum and Urine Gadolinium Reference Intervals in Patients With Normal Renal Function Following Gadobutrol Administration.","authors":"Jennifer S McDonald, Patrick L Day, Grant M Spears, Joshua A Bornhorst, Robert J McDonald, Paul J Jannetto","doi":"10.1097/RLI.0000000000001165","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Gadolinium-based contrast agents (GBCAs) increase the sensitivity and clinical utility of magnetic resonance imaging (MRI) examinations and are used extensively worldwide. While concerns remain regarding the potential toxicity of retained gadolinium (Gd) based on \"elevated\" serum or urinary Gd concentrations, current Gd reference intervals were established in GBCA-naive patients with normal renal function. Therefore, the aim of this study was to determine the serum and urine Gd clearance in patients with normal renal function after being administered intravenous gadobutrol for a contrast-enhanced MRI examination.</p><p><strong>Methods: </strong>Patients with normal renal function (estimated glomerular filtration rate ≥60 mL/min) with no prior GBCA exposure in the past 6 months were enrolled and had blood and urine collected before and ~1, 3, 7, 14, 28, 56, and 84 days after their gadobutrol-enhanced MRI examination to measure Gd at each time point. Serum and urine Gd were quantified using a clinically validated inductively coupled plasma mass spectrometry-based assay with a limit of quantitation of 0.1 ng/mL (μg/L).</p><p><strong>Results: </strong>Thirty-one patients who underwent a gadobutrol-enhanced MRI were enrolled, and 24 completed all collection time points. The pharmacokinetic data suggested a multicompartment (5 phase) model of elimination where 95% of patient's serum Gd fell below the unexposed reference interval (<0.5 ng/mL) at ~56 days and 95% of urine Gd would fall below the unexposed reference interval (<0.8 μg/g creatinine) at ~132 days. Based on review of the electronic medical record, none of the patients self-reported any Gd-related toxicity.</p><p><strong>Conclusions: </strong>Current reference intervals for serum and urinary gadolinium clearance are not applicable for patients in the 5 months following intravenous gadobutrol exposure.</p>","PeriodicalId":14486,"journal":{"name":"Investigative Radiology","volume":" ","pages":""},"PeriodicalIF":7.0000,"publicationDate":"2025-02-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Investigative Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RLI.0000000000001165","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Gadolinium-based contrast agents (GBCAs) increase the sensitivity and clinical utility of magnetic resonance imaging (MRI) examinations and are used extensively worldwide. While concerns remain regarding the potential toxicity of retained gadolinium (Gd) based on "elevated" serum or urinary Gd concentrations, current Gd reference intervals were established in GBCA-naive patients with normal renal function. Therefore, the aim of this study was to determine the serum and urine Gd clearance in patients with normal renal function after being administered intravenous gadobutrol for a contrast-enhanced MRI examination.

Methods: Patients with normal renal function (estimated glomerular filtration rate ≥60 mL/min) with no prior GBCA exposure in the past 6 months were enrolled and had blood and urine collected before and ~1, 3, 7, 14, 28, 56, and 84 days after their gadobutrol-enhanced MRI examination to measure Gd at each time point. Serum and urine Gd were quantified using a clinically validated inductively coupled plasma mass spectrometry-based assay with a limit of quantitation of 0.1 ng/mL (μg/L).

Results: Thirty-one patients who underwent a gadobutrol-enhanced MRI were enrolled, and 24 completed all collection time points. The pharmacokinetic data suggested a multicompartment (5 phase) model of elimination where 95% of patient's serum Gd fell below the unexposed reference interval (<0.5 ng/mL) at ~56 days and 95% of urine Gd would fall below the unexposed reference interval (<0.8 μg/g creatinine) at ~132 days. Based on review of the electronic medical record, none of the patients self-reported any Gd-related toxicity.

Conclusions: Current reference intervals for serum and urinary gadolinium clearance are not applicable for patients in the 5 months following intravenous gadobutrol exposure.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肾功能正常患者服用钆布醇后的血清和尿液钆参考区间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Investigative Radiology
Investigative Radiology 医学-核医学
CiteScore
15.10
自引率
16.40%
发文量
188
审稿时长
4-8 weeks
期刊介绍: Investigative Radiology publishes original, peer-reviewed reports on clinical and laboratory investigations in diagnostic imaging, the diagnostic use of radioactive isotopes, computed tomography, positron emission tomography, magnetic resonance imaging, ultrasound, digital subtraction angiography, and related modalities. Emphasis is on early and timely publication. Primarily research-oriented, the journal also includes a wide variety of features of interest to clinical radiologists.
期刊最新文献
Photon-Counting Detector CT Applications in Musculoskeletal Radiology. Focused Ultrasound: Noninvasive Image-Guided Therapy. Deep Learning-Enhanced Accelerated 2D TSE and 3D Superresolution Dixon TSE for Rapid Comprehensive Knee Joint Assessment. Hot Topics in Diagnostic Imaging-Encompassing Advances in MR, Photon-Counting CT, and Ultrasound. Three-Dimensional Magnetic Resonance Imaging in the Musculoskeletal System: Clinical Applications and Opportunities to Improve Imaging Speed and Resolution.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1