Contact Pressure, sliding distance and wear rate analysis at trunnion of hip implant for daily Activities: A finite element approach

IF 5.3 2区 医学 Q1 ENGINEERING, BIOMEDICAL Biocybernetics and Biomedical Engineering Pub Date : 2025-02-24 DOI:10.1016/j.bbe.2025.02.001
Md Mohiuddin Soliman , Mohammad Tariqul Islam , Phumin Kirawanich , Muhammad E.H. Chowdhury , Touhidul Alam , Ayed M. Alrashdi , Norbahiah Misran , Mohamed S. Soliman
{"title":"Contact Pressure, sliding distance and wear rate analysis at trunnion of hip implant for daily Activities: A finite element approach","authors":"Md Mohiuddin Soliman ,&nbsp;Mohammad Tariqul Islam ,&nbsp;Phumin Kirawanich ,&nbsp;Muhammad E.H. Chowdhury ,&nbsp;Touhidul Alam ,&nbsp;Ayed M. Alrashdi ,&nbsp;Norbahiah Misran ,&nbsp;Mohamed S. Soliman","doi":"10.1016/j.bbe.2025.02.001","DOIUrl":null,"url":null,"abstract":"<div><div>This research analyses contact pressure, sliding distance, and wear rate at the trunnion interface of hip implants during various activities to understand post-hip replacement outcomes. The study uses a numerical model and ISO-7206–6:2013 constraints with an AML hip implant. Greater F<sub>x</sub>, F<sub>y</sub>, and F<sub>z</sub> forces broaden contact pressure distribution. The highest pressure occurs on the proximal superolateral surface, with the lowest on the anterior and posterior surfaces. The HIGH100 (individuals weighing above 100 kg) weight category demonstrates 2 times higher maximum and average contact pressure compared to AVG75 (individuals weighing 75 kg) for sit-down and knee bend activities. Force components and the duration of a full gait cycle influence sliding distance. Stance activities show the highest sliding distance due to rapid changes in force load during the gait cycle. For sit-down and knee bend activities, the total sliding distance is 2.5 times higher in the HIGH100 weight category compared to AVG75. Sliding distance primarily occurs at the proximal superolateral-inferomedial-anterior-posterior contact surface, decreasing distally. Based on contact pressure, sliding distance, and wear volume rate, jogging and stance activities pose the highest risk for hip replacement patients, while cycling is the safest. The HIGH100 weight group exhibits 5- and 4-times greater wear volume rates than AVG75 in sit-down and knee bend activities, respectively. The research findings align with wear degradation observed in retrieved hip implants, validating the study. These insights can assist patients in making informed decisions about performing activities after surgery while enabling physicians to provide accurate guidelines.</div></div>","PeriodicalId":55381,"journal":{"name":"Biocybernetics and Biomedical Engineering","volume":"45 2","pages":"Pages 137-153"},"PeriodicalIF":5.3000,"publicationDate":"2025-02-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biocybernetics and Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0208521625000063","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This research analyses contact pressure, sliding distance, and wear rate at the trunnion interface of hip implants during various activities to understand post-hip replacement outcomes. The study uses a numerical model and ISO-7206–6:2013 constraints with an AML hip implant. Greater Fx, Fy, and Fz forces broaden contact pressure distribution. The highest pressure occurs on the proximal superolateral surface, with the lowest on the anterior and posterior surfaces. The HIGH100 (individuals weighing above 100 kg) weight category demonstrates 2 times higher maximum and average contact pressure compared to AVG75 (individuals weighing 75 kg) for sit-down and knee bend activities. Force components and the duration of a full gait cycle influence sliding distance. Stance activities show the highest sliding distance due to rapid changes in force load during the gait cycle. For sit-down and knee bend activities, the total sliding distance is 2.5 times higher in the HIGH100 weight category compared to AVG75. Sliding distance primarily occurs at the proximal superolateral-inferomedial-anterior-posterior contact surface, decreasing distally. Based on contact pressure, sliding distance, and wear volume rate, jogging and stance activities pose the highest risk for hip replacement patients, while cycling is the safest. The HIGH100 weight group exhibits 5- and 4-times greater wear volume rates than AVG75 in sit-down and knee bend activities, respectively. The research findings align with wear degradation observed in retrieved hip implants, validating the study. These insights can assist patients in making informed decisions about performing activities after surgery while enabling physicians to provide accurate guidelines.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
16.50
自引率
6.20%
发文量
77
审稿时长
38 days
期刊介绍: Biocybernetics and Biomedical Engineering is a quarterly journal, founded in 1981, devoted to publishing the results of original, innovative and creative research investigations in the field of Biocybernetics and biomedical engineering, which bridges mathematical, physical, chemical and engineering methods and technology to analyse physiological processes in living organisms as well as to develop methods, devices and systems used in biology and medicine, mainly in medical diagnosis, monitoring systems and therapy. The Journal''s mission is to advance scientific discovery into new or improved standards of care, and promotion a wide-ranging exchange between science and its application to humans.
期刊最新文献
Observer-based linear state-dependent control for blood glucose regulation in type 1 diabetic patients with unknown delays A feedback loop study of brain-heart interaction based on HEP and HRV A multidomain 0D model for continuous positive airway pressure ventilation circuit design: Validation and applications Electroencephalograph (EEG) based classification of mental arithmetic using explainable machine learning Contact Pressure, sliding distance and wear rate analysis at trunnion of hip implant for daily Activities: A finite element approach
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1