{"title":"Paper-based molecularly imprinted film designs for sensing human serum albumin","authors":"Tzu-Chieh Lin ,&nbsp;Chung-Yin Lin ,&nbsp;Yi-Ting Hwang ,&nbsp;Dar-Fu Tai","doi":"10.1016/j.talo.2025.100421","DOIUrl":null,"url":null,"abstract":"<div><div>A general, simple, and inexpensive method for fast and high throughput that monitors target model proteins and the sequential incorporation of functional monomers were presented for the preparation of molecularly imprinted films (MIFs) on cellulose filter papers (MIFPs). Owing to the inaccessibility of the fatty acid binding sites on human serum albumin (HSA), four classified-segment peptides with different chain lengths (i.e., HSA<sub>112–122</sub>, HSA<sub>302–313</sub>, HSA<sub>500–511</sub>, and HSA<sub>568–582</sub>) were selected and tested with regard to both MIFPs enrichment and fluorescent detection. The novel HSA MIFPs that designed for this study involve a monomer crosslinker instead of the commonly used crosslinker. Imprinted cavities took shape in different solvent systems on MIFPs because the conformation of the template peptide is fixed. When the solvent system changed to a 70% 2,2,2-trifluoroethanol (TFE) solution, the conformation of the peptide chains changed from an extended coil structure to a helix structure. Therefore, the film bound to the mother protein selectively. The imprinting conditions were optimized while the binding affinity, adsorption kinetics, and selectivity of the MIFPs for each template peptide were also evaluated. Fluorescence assays led to generate Scatchard plots revealing that, for <span><math><msubsup><mtext>MIFP</mtext><mrow><mn>568</mn><mo>−</mo><mn>582</mn></mrow><mtext>Helix</mtext></msubsup></math></span>, HSA had a dissociation constant (<em>K</em><sub>d</sub>) of 4.8 μM and a maximum bind capacity (<em>B</em><sub>max</sub>) of 0.5604 nmole. The binding selectivity was 10-folds more sensitive than <span><math><msubsup><mtext>MIFP</mtext><mrow><mn>568</mn><mo>−</mo><mn>582</mn></mrow><mrow><mtext>Random</mtext><mspace></mspace><mtext>coil</mtext></mrow></msubsup></math></span>. As for the <span><math><msubsup><mtext>MIFP</mtext><mrow><mn>568</mn><mo>−</mo><mn>582</mn></mrow><mtext>Helix</mtext></msubsup></math></span> response time was found to be 5 min. In short, a combined fluorescent platform could be used to monitor and capture proteins conveniently, inexpensively, quickly, and accurately detect without the need of too much professional input.</div></div>","PeriodicalId":436,"journal":{"name":"Talanta Open","volume":"11 ","pages":"Article 100421"},"PeriodicalIF":3.7000,"publicationDate":"2025-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666831925000244","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/18 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

A general, simple, and inexpensive method for fast and high throughput that monitors target model proteins and the sequential incorporation of functional monomers were presented for the preparation of molecularly imprinted films (MIFs) on cellulose filter papers (MIFPs). Owing to the inaccessibility of the fatty acid binding sites on human serum albumin (HSA), four classified-segment peptides with different chain lengths (i.e., HSA112–122, HSA302–313, HSA500–511, and HSA568–582) were selected and tested with regard to both MIFPs enrichment and fluorescent detection. The novel HSA MIFPs that designed for this study involve a monomer crosslinker instead of the commonly used crosslinker. Imprinted cavities took shape in different solvent systems on MIFPs because the conformation of the template peptide is fixed. When the solvent system changed to a 70% 2,2,2-trifluoroethanol (TFE) solution, the conformation of the peptide chains changed from an extended coil structure to a helix structure. Therefore, the film bound to the mother protein selectively. The imprinting conditions were optimized while the binding affinity, adsorption kinetics, and selectivity of the MIFPs for each template peptide were also evaluated. Fluorescence assays led to generate Scatchard plots revealing that, for MIFP568582Helix, HSA had a dissociation constant (Kd) of 4.8 μM and a maximum bind capacity (Bmax) of 0.5604 nmole. The binding selectivity was 10-folds more sensitive than MIFP568582Randomcoil. As for the MIFP568582Helix response time was found to be 5 min. In short, a combined fluorescent platform could be used to monitor and capture proteins conveniently, inexpensively, quickly, and accurately detect without the need of too much professional input.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于检测人血清白蛋白的纸基分子印迹膜设计
提出了一种通用、简单、廉价的快速、高通量的方法,用于监测目标模型蛋白和功能单体的顺序结合,用于在纤维素滤纸上制备分子印迹膜(MIFs)。由于人血清白蛋白(human serum albumin, HSA)的脂肪酸结合位点难以接近,我们选择了4个不同链长的分节肽(HSA112-122、HSA302-313、HSA500-511、HSA568-582)进行MIFPs富集和荧光检测。为本研究设计的新型HSA MIFPs采用单体交联剂代替常用的交联剂。由于模板肽的构象是固定的,印迹空腔在不同的溶剂体系中都能在MIFPs上形成。当溶剂体系改为70% 2,2,2-三氟乙醇(TFE)溶液时,肽链的构象由延长的线圈结构变为螺旋结构。因此,膜选择性地与母蛋白结合。优化印迹条件,评价印迹蛋白对模板肽的结合亲和力、吸附动力学和选择性。结果表明,HSA对MIFP568−582Helix的解离常数(Kd)为4.8 μM,最大结合容量(Bmax)为0.5604 nmol。结合选择性比MIFP568−582Randomcoil灵敏10倍。MIFP568−582Helix的响应时间为5 min。总之,一个组合的荧光平台可以方便、廉价、快速、准确地监测和捕获蛋白质,而不需要太多的专业投入。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Talanta Open
Talanta Open Chemistry-Analytical Chemistry
CiteScore
5.20
自引率
0.00%
发文量
86
审稿时长
49 days
期刊最新文献
Machine learning and artificial intelligence in perovskite quantum dot electroanalysis: From data-driven synthesis to intelligent sensing interfaces Dual capillary ion chromatography-mass spectrometry for the analysis of inorganic and organic ions in a high-resolution Antarctic ice core: Concentrations, trends, and synergies Dual-T lines fluorescent immunochromatographic strip based on CdSe/ZnS QD microspheres: preparation and application for rapid detection of porcine pathogens Gold nanoparticles/ZIF-8 MOFs as amplifier and few carbon nanotubes@β-cyclodextrin as carrier for sandwich-like electrochemical immunosensing of thyroid globulin Cationic‒anionic dye mixtures in writing inks: A straightforward multianalytical approach for minute samples
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1