{"title":"Development and comprehensive clinical validation of a deep neural network for radiation dose modelling to enhance magnetic resonance imaging guided radiotherapy","authors":"Moritz Schneider ,&nbsp;Simon Gutwein ,&nbsp;David Mönnich ,&nbsp;Cihan Gani ,&nbsp;Paul Fischer ,&nbsp;Christian F. Baumgartner ,&nbsp;Daniela Thorwarth","doi":"10.1016/j.phro.2025.100723","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and purpose</h3><div>Online adaptive magnetic resonance imaging (MRI)-guided radiotherapy requires fast dose calculation algorithms to reduce intra-fraction motion uncertainties and improve workflow efficiency. While Monte-Carlo simulations are precise but computationally intensive, neural networks promise fast and accurate dose modelling in strong magnetic fields. This study aimed to train and evaluate a deep neural network for dose modelling in MRI-guided radiotherapy using a comprehensive clinical dataset.</div></div><div><h3>Materials and methods</h3><div>A dataset of 6595 clinical irradiation segments from 125 1.5 T MRI-Linac radiotherapy plans for various tumors sites was used. A 3D U-Net was trained with 3961 segments using 3D imaging data and field parameters as input, Root Mean Squared Error and a custom loss function, with full Monte-Carlo simulations as ground truth. For 2656 segments from 50 patients, gamma pass rates (γ-PR) for 3 mm/3%, 2 mm/2%, and 1 mm/1% criteria were calculated to assess dose modelling accuracy. Performance was also tested in a standardized water phantom to evaluate basic radiation physics properties.</div></div><div><h3>Results</h3><div>The neural network accurately modeled dose distributions in both patient and water phantom settings. Median (range) γ-PR of 97.7% (87.5–100.0%), 89.1% (69.7–99.4%), and 60.8% (38.5–82.1%) were observed for treatment plans, and 97.1% (55.5–100.0%), 88.8% (38.8–99.7%), and 61.7% (17.9–94.4%) for individual segments, across the three criteria.</div></div><div><h3>Conclusion</h3><div>High median γ-PR and accurate modelling in both water phantom and clinical data demonstrate the high potential of neural networks for dose modelling. However, instances of lower γ-PR highlight the need for comprehensive test data, improved robustness and future built-in uncertainty estimation.</div></div>","PeriodicalId":36850,"journal":{"name":"Physics and Imaging in Radiation Oncology","volume":"33 ","pages":"Article 100723"},"PeriodicalIF":3.3000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics and Imaging in Radiation Oncology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2405631625000284","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/7 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and purpose

Online adaptive magnetic resonance imaging (MRI)-guided radiotherapy requires fast dose calculation algorithms to reduce intra-fraction motion uncertainties and improve workflow efficiency. While Monte-Carlo simulations are precise but computationally intensive, neural networks promise fast and accurate dose modelling in strong magnetic fields. This study aimed to train and evaluate a deep neural network for dose modelling in MRI-guided radiotherapy using a comprehensive clinical dataset.

Materials and methods

A dataset of 6595 clinical irradiation segments from 125 1.5 T MRI-Linac radiotherapy plans for various tumors sites was used. A 3D U-Net was trained with 3961 segments using 3D imaging data and field parameters as input, Root Mean Squared Error and a custom loss function, with full Monte-Carlo simulations as ground truth. For 2656 segments from 50 patients, gamma pass rates (γ-PR) for 3 mm/3%, 2 mm/2%, and 1 mm/1% criteria were calculated to assess dose modelling accuracy. Performance was also tested in a standardized water phantom to evaluate basic radiation physics properties.

Results

The neural network accurately modeled dose distributions in both patient and water phantom settings. Median (range) γ-PR of 97.7% (87.5–100.0%), 89.1% (69.7–99.4%), and 60.8% (38.5–82.1%) were observed for treatment plans, and 97.1% (55.5–100.0%), 88.8% (38.8–99.7%), and 61.7% (17.9–94.4%) for individual segments, across the three criteria.

Conclusion

High median γ-PR and accurate modelling in both water phantom and clinical data demonstrate the high potential of neural networks for dose modelling. However, instances of lower γ-PR highlight the need for comprehensive test data, improved robustness and future built-in uncertainty estimation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
开发和全面临床验证的深度神经网络辐射剂量建模,以增强磁共振成像引导放射治疗
背景与目的在线自适应磁共振成像(MRI)引导放射治疗需要快速的剂量计算算法,以减少分数内运动的不确定性,提高工作效率。虽然蒙特卡罗模拟很精确,但计算量很大,但神经网络有望在强磁场中快速准确地建立剂量模型。本研究旨在利用综合临床数据集训练和评估用于mri引导放射治疗剂量建模的深度神经网络。材料和方法使用125个1.5 T MRI-Linac放射治疗计划中6595个临床放疗片段的数据集,用于不同肿瘤部位。使用三维成像数据和现场参数作为输入,均方根误差和自定义损失函数,以完整的蒙特卡罗模拟为基础,训练了3961个片段的3D U-Net。对来自50名患者的2656个节段,计算3mm /3%、2mm /2%和1mm /1%标准下的伽马通过率(γ-PR),以评估剂量建模的准确性。还在标准水模中进行了性能测试,以评估基本的辐射物理特性。结果神经网络准确地模拟了患者和水影环境下的剂量分布。治疗方案的γ-PR中位数(范围)分别为97.7%(87.5-100.0%)、89.1%(69.7-99.4%)和60.8%(38.5-82.1%),三个标准中单个区段的γ-PR中位数(范围)分别为97.1%(55.5-100.0%)、88.8%(38.8-99.7%)和61.7%(17.9-94.4%)。结论高中位γ-PR和准确的水影模型和临床数据表明神经网络在剂量模型中具有很高的应用潜力。然而,较低γ-PR的实例强调需要全面的测试数据,改进的鲁棒性和未来内置的不确定性估计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Physics and Imaging in Radiation Oncology
Physics and Imaging in Radiation Oncology Physics and Astronomy-Radiation
CiteScore
5.30
自引率
18.90%
发文量
93
审稿时长
6 weeks
期刊最新文献
Reduced beam time and distal linear energy transfer with mini-ridge filters in pencil beam scanning proton therapy Comparative analysis of artificial intelligence-based contouring of cardiac substructures on computed tomography scans for radiation therapy A meta-analysis of dose-volume parameters and treatment efficiency comparing O-ring and C-arm accelerator systems for craniospinal irradiations An efficient automated approach for accumulated dose estimation in prostate cancer radiotherapy Reduction of organ of interest dose in proton therapy for oesophageal cancer through optimized setup robustness settings and online adaptation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1