In-Silico Investigation of 3D Quantitative Angiography for Internal Carotid Aneurysms Using Biplane Imaging and 3D Vascular Geometry Constraints.

ArXiv Pub Date : 2025-02-13
Kyle A Williams, Swetadri Vasan Setlur Nagesh, Daniel R Bednarek, Stephen Rudin, Ciprian N Ionita
{"title":"In-Silico Investigation of 3D Quantitative Angiography for Internal Carotid Aneurysms Using Biplane Imaging and 3D Vascular Geometry Constraints.","authors":"Kyle A Williams, Swetadri Vasan Setlur Nagesh, Daniel R Bednarek, Stephen Rudin, Ciprian N Ionita","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Quantitative angiography (QA) in two dimensions has been instrumental in assessing neurovascular contrast flow patterns, aiding disease severity and treatment outcome evaluations. However, QA requires high spatio-temporal resolution, restricting its use to digital subtraction angiography (DSA), and is prone to errors in quantification of highly 3D flow patterns. This study examines whether 3D QA information can be recovered by reconstructing four-dimensional (4D) angiography using data from standard clinical imaging protocols. Patient-specific internal carotid aneurysm models were used to generate high-fidelity computational fluid dynamics (CFD) simulations of contrast flow. The resulting 4D angiograms were used to simulate biplane DSA under clinical imaging protocols. 4D angiography was reconstructed from two views using back-projection constrained by an a priori 3D geometry. Quantitative angiographic parametric imaging (API) metrics obtained from the CFD-based 4D angiography and reconstructed 4D angiography were compared using mean square error (MSE) and mean absolute percentage error (MAPE). The reconstructed 4D datasets effectively captured 3D flow dynamics, achieving an average MSE of 0.007 across models and flow conditions. API metrics such as PH and AUC closely matched the CFD ground truth, with temporal metrics showing some variability in regions with overlapping projections. These results demonstrate the potential to recover 3D QA information using simulated 4D angiography constrained by standard clinical imaging parameters. The method provides a robust framework for evaluating and improving QA in clinical neurovascular applications, offering new insights into the dynamics of aneurysmal contrast flow.</p>","PeriodicalId":93888,"journal":{"name":"ArXiv","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11844626/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ArXiv","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Quantitative angiography (QA) in two dimensions has been instrumental in assessing neurovascular contrast flow patterns, aiding disease severity and treatment outcome evaluations. However, QA requires high spatio-temporal resolution, restricting its use to digital subtraction angiography (DSA), and is prone to errors in quantification of highly 3D flow patterns. This study examines whether 3D QA information can be recovered by reconstructing four-dimensional (4D) angiography using data from standard clinical imaging protocols. Patient-specific internal carotid aneurysm models were used to generate high-fidelity computational fluid dynamics (CFD) simulations of contrast flow. The resulting 4D angiograms were used to simulate biplane DSA under clinical imaging protocols. 4D angiography was reconstructed from two views using back-projection constrained by an a priori 3D geometry. Quantitative angiographic parametric imaging (API) metrics obtained from the CFD-based 4D angiography and reconstructed 4D angiography were compared using mean square error (MSE) and mean absolute percentage error (MAPE). The reconstructed 4D datasets effectively captured 3D flow dynamics, achieving an average MSE of 0.007 across models and flow conditions. API metrics such as PH and AUC closely matched the CFD ground truth, with temporal metrics showing some variability in regions with overlapping projections. These results demonstrate the potential to recover 3D QA information using simulated 4D angiography constrained by standard clinical imaging parameters. The method provides a robust framework for evaluating and improving QA in clinical neurovascular applications, offering new insights into the dynamics of aneurysmal contrast flow.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
MassSpecGym: A benchmark for the discovery and identification of molecules. The shape of the brain's connections is predictive of cognitive performance: an explainable machine learning study. A Physics-Informed Deep Learning Model for MRI Brain Motion Correction. In-Silico Investigation of 3D Quantitative Angiography for Internal Carotid Aneurysms Using Biplane Imaging and 3D Vascular Geometry Constraints. Optimizing Global Genomic Surveillance for Early Detection of Emerging SARS-CoV-2 Variants.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1