{"title":"Simple, cost-effective, highly stable solid-state photoluminescence standard for fluorometer calibration in low-resource settings.","authors":"Joshua Eger, Mark Bailly, Jennifer Blain Christen","doi":"10.1364/OPTCON.534029","DOIUrl":null,"url":null,"abstract":"<p><p>The proposed photoluminescence calibration standard comprises a solid-state phosphor film, neutral density gel filter(s), and a 3D-printed optomechanical cartridge. The proposed standard demonstrated exceptional photostability; photoluminescence did not deviate from the baseline more than 1.27% under 5 minutes of continuous illumination. Remarkably, there was no measurable degradation over a 3-year study. Precise photoluminescence intensity modulation was accomplished with neutral density gel filters (R<sup>2</sup> > 0.9982) and optical apertures (R<sup>2</sup> > 0.9970). A model for photoluminescence intensity as a function of neutral-density filter and optical aperture parameters yielded a mean percentage error (MPE) of 2.79%, indicating high precision. Inter-sample variability was low, with a mean coefficient of variation (CV) of 1.32%. Mean CV across 24 channels decreased from 11.88% to 1.51% following multi-point calibration of multichannel point-of-care (POC) fluorometers. Cost analysis revealed a per-unit cost between $0.49 to $1.80. This work suggests that the proposed calibration standards provide a cost-effective, highly stable solution for reliable fluorometer calibration in low-resource settings.</p>","PeriodicalId":74366,"journal":{"name":"Optics continuum","volume":"3 11","pages":"2060-2077"},"PeriodicalIF":1.1000,"publicationDate":"2024-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11844768/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optics continuum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1364/OPTCON.534029","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/31 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 0
Abstract
The proposed photoluminescence calibration standard comprises a solid-state phosphor film, neutral density gel filter(s), and a 3D-printed optomechanical cartridge. The proposed standard demonstrated exceptional photostability; photoluminescence did not deviate from the baseline more than 1.27% under 5 minutes of continuous illumination. Remarkably, there was no measurable degradation over a 3-year study. Precise photoluminescence intensity modulation was accomplished with neutral density gel filters (R2 > 0.9982) and optical apertures (R2 > 0.9970). A model for photoluminescence intensity as a function of neutral-density filter and optical aperture parameters yielded a mean percentage error (MPE) of 2.79%, indicating high precision. Inter-sample variability was low, with a mean coefficient of variation (CV) of 1.32%. Mean CV across 24 channels decreased from 11.88% to 1.51% following multi-point calibration of multichannel point-of-care (POC) fluorometers. Cost analysis revealed a per-unit cost between $0.49 to $1.80. This work suggests that the proposed calibration standards provide a cost-effective, highly stable solution for reliable fluorometer calibration in low-resource settings.