Fluorescent/colorimetric dual-mode for detecting of MC-LR using bidirectional RCA coupled with CdTe QDs

IF 5.3 2区 化学 Q1 CHEMISTRY, ANALYTICAL Microchimica Acta Pub Date : 2025-02-25 DOI:10.1007/s00604-025-06991-8
Weiqing Sun, Xinru Ren, Yijing Xiao, Bowen Li, Qing-ao Pang, Meili Yang, Rui Zhu, Zhiqiang Guo, Jinghua Yu, Jiadong Huang, Yu Wang, Su Liu
{"title":"Fluorescent/colorimetric dual-mode for detecting of MC-LR using bidirectional RCA coupled with CdTe QDs","authors":"Weiqing Sun,&nbsp;Xinru Ren,&nbsp;Yijing Xiao,&nbsp;Bowen Li,&nbsp;Qing-ao Pang,&nbsp;Meili Yang,&nbsp;Rui Zhu,&nbsp;Zhiqiang Guo,&nbsp;Jinghua Yu,&nbsp;Jiadong Huang,&nbsp;Yu Wang,&nbsp;Su Liu","doi":"10.1007/s00604-025-06991-8","DOIUrl":null,"url":null,"abstract":"<div><p> A fluorescent/colorimetric dual-mode biosensor was designed using CdTe QDs and CRISPR/Cas for the efficient and ultrasensitive detection of microcystin-leucine-arginine (MC-LR). The biosensor mainly activates the trans-cleavage activity of Cas12a through nucleic acid amplification technology, such as bidirectional rolling circle amplification (B-RCA), to perform signal conversion, release Ag<sup>+</sup> from the cleaving hairpin, quench QD fluorescence, and perform signal presentation. The biosensor can perform fluorometric and colorimetric detection, enabling rapid field assays. It exhibits enhanced selectivity, increased sensitivity, and greater accuracy. The optimal conditions yield a detection range from 0.05 to 500 nM, with a minimum detectable concentration of 2.137 pM, surpassing the performance of traditional methods. The biosensor can effectively detect MC-LR in actual environmental samples. Overall, this study provided a general detection approach for the application of nucleic acid detection technology to detect trace pollutants in the environment.</p><h3>Graphical Abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":705,"journal":{"name":"Microchimica Acta","volume":"192 3","pages":""},"PeriodicalIF":5.3000,"publicationDate":"2025-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchimica Acta","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s00604-025-06991-8","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

A fluorescent/colorimetric dual-mode biosensor was designed using CdTe QDs and CRISPR/Cas for the efficient and ultrasensitive detection of microcystin-leucine-arginine (MC-LR). The biosensor mainly activates the trans-cleavage activity of Cas12a through nucleic acid amplification technology, such as bidirectional rolling circle amplification (B-RCA), to perform signal conversion, release Ag+ from the cleaving hairpin, quench QD fluorescence, and perform signal presentation. The biosensor can perform fluorometric and colorimetric detection, enabling rapid field assays. It exhibits enhanced selectivity, increased sensitivity, and greater accuracy. The optimal conditions yield a detection range from 0.05 to 500 nM, with a minimum detectable concentration of 2.137 pM, surpassing the performance of traditional methods. The biosensor can effectively detect MC-LR in actual environmental samples. Overall, this study provided a general detection approach for the application of nucleic acid detection technology to detect trace pollutants in the environment.

Graphical Abstract

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用双向RCA耦合CdTe量子点的荧光/比色双模式检测MC-LR
利用CdTe QDs和CRISPR/Cas设计了一种荧光/比色双模式生物传感器,用于高效、超灵敏地检测微囊藻毒素-亮氨酸-精氨酸(MC-LR)。该生物传感器主要通过双向滚圆扩增(B-RCA)等核酸扩增技术激活 Cas12a 的反向裂解活性,进行信号转换,释放裂解发夹中的 Ag+,淬灭 QD 荧光,进行信号呈现。该生物传感器可进行荧光和比色检测,实现快速现场检测。它具有更强的选择性、更高的灵敏度和更高的准确性。最佳条件下的检测范围为 0.05 至 500 nM,最低检测浓度为 2.137 pM,超越了传统方法的性能。该生物传感器能有效检测实际环境样品中的 MC-LR。总之,这项研究为应用核酸检测技术检测环境中的痕量污染物提供了一种通用的检测方法。 图文摘要
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
文献相关原料
公司名称
产品信息
麦克林
microcystin-leucine-arginine
来源期刊
Microchimica Acta
Microchimica Acta 化学-分析化学
CiteScore
9.80
自引率
5.30%
发文量
410
审稿时长
2.7 months
期刊介绍: As a peer-reviewed journal for analytical sciences and technologies on the micro- and nanoscale, Microchimica Acta has established itself as a premier forum for truly novel approaches in chemical and biochemical analysis. Coverage includes methods and devices that provide expedient solutions to the most contemporary demands in this area. Examples are point-of-care technologies, wearable (bio)sensors, in-vivo-monitoring, micro/nanomotors and materials based on synthetic biology as well as biomedical imaging and targeting.
期刊最新文献
A quenched electrochemiluminescence immunosensor based on luminol-Au NPs/Co-Fe-MOF and CuO@UiO-66-NH2 for influenza A hemagglutinin detection. The fabrication of novel Ce-MOGs with effective nitrite detection performance in food. Fluorescent molecularly imprinted polymer sensor prepared using mesoporous silica as carrier for selective detection of bisphenol A. Selective detection of arsenite in alkaline media using a yolk-shell (Ce/Fe) terephthalate/organoclay framework stripping voltammetric sensor. Heteroatoms-functionalized carbon dots as chemiluminescence probe for the detection of sulfide and puerarin
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1