{"title":"Design and validation of an alignment free adaptive joint torque measurement system.","authors":"Lei Li, Jingcheng Chen, Shaoming Sun, Wei Peng","doi":"10.1186/s12938-025-01356-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study introduces a transferable alignment-free adaptive joint torque measurement (AFAJTM) system designed to resolve inconsistencies in torque measurements caused by misalignment between dynamometer and joint rotational axes, improving accuracy and reliability in joint torque assessment.</p><p><strong>Method: </strong>This study presents the design and control methodology of an alignment free adaptive joint torque measurement system. An elbow joint torque measurement device (EJTMD) was developed, and its torque consistency and repeatability were evaluated at various misalignment positions using a joint simulation model. Clinical experiments compared torque measurements between the EJTMD and a traditional standard dynamometer during maximum voluntary contraction (MVC) tests at different misalignment positions.</p><p><strong>Result: </strong>The simulation test results demonstrate that the AFAJTM system can achieve high-precision torque measurements, with measurement errors controlled within ± 0.5 Nm at various misalignment positions. Clinical experiment data show that the EJTMD exhibits high consistency in torque measurements compared to the traditional standard dynamometer across five different misalignment positions, with strong repeatability and reliability.</p><p><strong>Conclusion: </strong>The AFAJTM system provides a novel solution for joint torque measurement under human-machine axis misalignment conditions, a solution that eliminates the need for axis alignment, effectively overcoming the limitations of traditional measurement devices. This system can be widely applied in various devices that require joint torque measurement, demonstrating excellent adaptability and high-precision measurement capabilities.</p>","PeriodicalId":8927,"journal":{"name":"BioMedical Engineering OnLine","volume":"24 1","pages":"25"},"PeriodicalIF":2.9000,"publicationDate":"2025-02-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BioMedical Engineering OnLine","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1186/s12938-025-01356-x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study introduces a transferable alignment-free adaptive joint torque measurement (AFAJTM) system designed to resolve inconsistencies in torque measurements caused by misalignment between dynamometer and joint rotational axes, improving accuracy and reliability in joint torque assessment.

Method: This study presents the design and control methodology of an alignment free adaptive joint torque measurement system. An elbow joint torque measurement device (EJTMD) was developed, and its torque consistency and repeatability were evaluated at various misalignment positions using a joint simulation model. Clinical experiments compared torque measurements between the EJTMD and a traditional standard dynamometer during maximum voluntary contraction (MVC) tests at different misalignment positions.

Result: The simulation test results demonstrate that the AFAJTM system can achieve high-precision torque measurements, with measurement errors controlled within ± 0.5 Nm at various misalignment positions. Clinical experiment data show that the EJTMD exhibits high consistency in torque measurements compared to the traditional standard dynamometer across five different misalignment positions, with strong repeatability and reliability.

Conclusion: The AFAJTM system provides a novel solution for joint torque measurement under human-machine axis misalignment conditions, a solution that eliminates the need for axis alignment, effectively overcoming the limitations of traditional measurement devices. This system can be widely applied in various devices that require joint torque measurement, demonstrating excellent adaptability and high-precision measurement capabilities.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
BioMedical Engineering OnLine
BioMedical Engineering OnLine 工程技术-工程:生物医学
CiteScore
6.70
自引率
2.60%
发文量
79
审稿时长
1 months
期刊介绍: BioMedical Engineering OnLine is an open access, peer-reviewed journal that is dedicated to publishing research in all areas of biomedical engineering. BioMedical Engineering OnLine is aimed at readers and authors throughout the world, with an interest in using tools of the physical and data sciences and techniques in engineering to understand and solve problems in the biological and medical sciences. Topical areas include, but are not limited to: Bioinformatics- Bioinstrumentation- Biomechanics- Biomedical Devices & Instrumentation- Biomedical Signal Processing- Healthcare Information Systems- Human Dynamics- Neural Engineering- Rehabilitation Engineering- Biomaterials- Biomedical Imaging & Image Processing- BioMEMS and On-Chip Devices- Bio-Micro/Nano Technologies- Biomolecular Engineering- Biosensors- Cardiovascular Systems Engineering- Cellular Engineering- Clinical Engineering- Computational Biology- Drug Delivery Technologies- Modeling Methodologies- Nanomaterials and Nanotechnology in Biomedicine- Respiratory Systems Engineering- Robotics in Medicine- Systems and Synthetic Biology- Systems Biology- Telemedicine/Smartphone Applications in Medicine- Therapeutic Systems, Devices and Technologies- Tissue Engineering
期刊最新文献
Design and validation of an alignment free adaptive joint torque measurement system. Feasibility and reliability of an online version of the beat alignment test in neurotypical adults and people with stroke. Deep learning and electrocardiography: systematic review of current techniques in cardiovascular disease diagnosis and management. Cross-evaluation of wearable data for use in Parkinson's disease research: a free-living observational study on Empatica E4, Fitbit Sense, and Oura. Identification of anatomical locations: its relevance for vibrotactile perception of individuals with Parkinson's disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1