Application Value of A Clinical Radiomic Nomogram for Identifying Diabetic Nephropathy and Nondiabetic Renal Disease.

IF 1.1 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Current Medical Imaging Reviews Pub Date : 2025-02-24 DOI:10.2174/0115734056332507250210105723
Xiaoling Liu, Weihan Xiao, Jing Qiao, Xiachuan Qin
{"title":"Application Value of A Clinical Radiomic Nomogram for Identifying Diabetic Nephropathy and Nondiabetic Renal Disease.","authors":"Xiaoling Liu, Weihan Xiao, Jing Qiao, Xiachuan Qin","doi":"10.2174/0115734056332507250210105723","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>An ultrasound-based radiomics Machine Learning Model (ML) was utilized to assess non-invasively the conditions of diabetic nephropathy and non-diabetic renal disease in diabetic patients.</p><p><strong>Methods: </strong>A retrospective examination was conducted on 166 diabetic patients who had undergone renal biopsies guided by ultrasound, with the group comprising 114 individuals diagnosed with diabetic nephropathy and 52 with non-diabetic renal disease. The participants were randomly divided into the training set and the testing set (7:3). Following the extraction of radiomics features from the renal ultrasound images, a univariate analysis was conducted, and the Least Absolute Shrinkage And Selection Operator (LASSO) algorithm was applied to select the most significant features. Three ML algorithms were applied to construct the prediction models. Subsequently, the patients' clinical characteristics were evaluated through both univariate and multivariate logistic regression analyses, which facilitated the development of a clinical model, following a clinical radiomics model was formulated, integrating the radiomics scores (Radscore), along with the independent clinical variables identified through the screening process. The diagnostic performance of the three models constructed was evaluated using the receiver operating characteristic (ROC) curve analysis.</p><p><strong>Results: </strong>Among the three radiomics ML models, the logistic regression (LR) model achieved the best performance, with the area under the curve (AUC) values of 0.872 (95%CI, 0.800-0.944) and 0.836 (95%CI, 0.716-0.957) for the training set and the testing set, respectively. The decision curve analysis (DCA) verified the clinical practicability of the ML model. Within the same testing set, the AUC of the clinical model was 0.761 (95%CI, 0.606-0.916). The nomogram model based on clinical features plus Radscore showed the best discrimination, with an AUC value of 0.881 (95%CI, 0.779-0.982), which was better than that of the single clinical model and the radiomics model.</p><p><strong>Conclusion: </strong>The ML model of radiomics based on ultrasound images has potential value in the non-invasive differential diagnosis of patients with diabetic nephropathy. The nomogram constructed based on rad score and clinical features could effectively distinguish DN from NDRD.</p>","PeriodicalId":54215,"journal":{"name":"Current Medical Imaging Reviews","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2025-02-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Medical Imaging Reviews","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2174/0115734056332507250210105723","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: An ultrasound-based radiomics Machine Learning Model (ML) was utilized to assess non-invasively the conditions of diabetic nephropathy and non-diabetic renal disease in diabetic patients.

Methods: A retrospective examination was conducted on 166 diabetic patients who had undergone renal biopsies guided by ultrasound, with the group comprising 114 individuals diagnosed with diabetic nephropathy and 52 with non-diabetic renal disease. The participants were randomly divided into the training set and the testing set (7:3). Following the extraction of radiomics features from the renal ultrasound images, a univariate analysis was conducted, and the Least Absolute Shrinkage And Selection Operator (LASSO) algorithm was applied to select the most significant features. Three ML algorithms were applied to construct the prediction models. Subsequently, the patients' clinical characteristics were evaluated through both univariate and multivariate logistic regression analyses, which facilitated the development of a clinical model, following a clinical radiomics model was formulated, integrating the radiomics scores (Radscore), along with the independent clinical variables identified through the screening process. The diagnostic performance of the three models constructed was evaluated using the receiver operating characteristic (ROC) curve analysis.

Results: Among the three radiomics ML models, the logistic regression (LR) model achieved the best performance, with the area under the curve (AUC) values of 0.872 (95%CI, 0.800-0.944) and 0.836 (95%CI, 0.716-0.957) for the training set and the testing set, respectively. The decision curve analysis (DCA) verified the clinical practicability of the ML model. Within the same testing set, the AUC of the clinical model was 0.761 (95%CI, 0.606-0.916). The nomogram model based on clinical features plus Radscore showed the best discrimination, with an AUC value of 0.881 (95%CI, 0.779-0.982), which was better than that of the single clinical model and the radiomics model.

Conclusion: The ML model of radiomics based on ultrasound images has potential value in the non-invasive differential diagnosis of patients with diabetic nephropathy. The nomogram constructed based on rad score and clinical features could effectively distinguish DN from NDRD.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.60
自引率
0.00%
发文量
246
审稿时长
1 months
期刊介绍: Current Medical Imaging Reviews publishes frontier review articles, original research articles, drug clinical trial studies and guest edited thematic issues on all the latest advances on medical imaging dedicated to clinical research. All relevant areas are covered by the journal, including advances in the diagnosis, instrumentation and therapeutic applications related to all modern medical imaging techniques. The journal is essential reading for all clinicians and researchers involved in medical imaging and diagnosis.
期刊最新文献
A Novel Fragmentation-based Approach for Accurate Segmentation of Small-Sized Brain Tumors in MRI Images. Left Basal Ganglia Stroke-induced more Alterations of Functional Connectivity: Evidence from an fMRI Study. Demographic Characteristics of Pneumoconiosis Cases: A Single Centre Experience. A Robust Approach to Early Glaucoma Identification from Retinal Fundus Images using Dirichlet-based Weighted Average Ensemble and Bayesian Optimization. Application Value of A Clinical Radiomic Nomogram for Identifying Diabetic Nephropathy and Nondiabetic Renal Disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1