Kenan Dennis Sakmen, Christian Issing, Caterina Vazzana, Tobias Weißgerber, Albrecht Linke, Timo Stöver, Silke Helbig
{"title":"Cochlear implantation with Slim Modiolar Electrode carriers enables hearing preservation.","authors":"Kenan Dennis Sakmen, Christian Issing, Caterina Vazzana, Tobias Weißgerber, Albrecht Linke, Timo Stöver, Silke Helbig","doi":"10.1007/s00405-025-09267-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate hearing preservation in patients who received a cochlear implant with a preformed electrode carrier, namely the Slim Modiolar (SM).</p><p><strong>Methods: </strong>A monocentric, retrospective study was conducted. A total of 51 adult patients (24 females, 27 males), representing 60 ears, were included in the final evaluation. The mean age was 60.9 ± 15.2 years (range 17.5-89.7 years). All patients had some degree of residual hearing. Frequency-specific pure-tone audiometry was performed at three time points: preoperatively (T0), within 30 days postoperatively (T1), and at a later time point during follow-up (T2; 20.7 ± 17.6 months). Low frequency pure tone average and the HEARRING group formula were used to facilitate comparison of hearing preservation rates with other results published so far.</p><p><strong>Results: </strong>In the first month after surgery, no significant deterioration was observed for the low frequencies, but a significant deterioration was observed at follow-up. Using the HEARRING classification system, the average short-term (T0-T1) hearing preservation score was 70%, which corresponds to partial hearing preservation. During follow-up (T0-T2), the score decreased to 61% in the study group, still representing partial hearing preservation. Complete hearing loss occurred in 20% of the cases.</p><p><strong>Conclusion: </strong>Especially in the low frequency range, the utilisation of SM electrode carriers during cochlear implantation facilitates preservation of residual hearing.</p>","PeriodicalId":11952,"journal":{"name":"European Archives of Oto-Rhino-Laryngology","volume":" ","pages":""},"PeriodicalIF":1.9000,"publicationDate":"2025-02-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Archives of Oto-Rhino-Laryngology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00405-025-09267-2","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To investigate hearing preservation in patients who received a cochlear implant with a preformed electrode carrier, namely the Slim Modiolar (SM).
Methods: A monocentric, retrospective study was conducted. A total of 51 adult patients (24 females, 27 males), representing 60 ears, were included in the final evaluation. The mean age was 60.9 ± 15.2 years (range 17.5-89.7 years). All patients had some degree of residual hearing. Frequency-specific pure-tone audiometry was performed at three time points: preoperatively (T0), within 30 days postoperatively (T1), and at a later time point during follow-up (T2; 20.7 ± 17.6 months). Low frequency pure tone average and the HEARRING group formula were used to facilitate comparison of hearing preservation rates with other results published so far.
Results: In the first month after surgery, no significant deterioration was observed for the low frequencies, but a significant deterioration was observed at follow-up. Using the HEARRING classification system, the average short-term (T0-T1) hearing preservation score was 70%, which corresponds to partial hearing preservation. During follow-up (T0-T2), the score decreased to 61% in the study group, still representing partial hearing preservation. Complete hearing loss occurred in 20% of the cases.
Conclusion: Especially in the low frequency range, the utilisation of SM electrode carriers during cochlear implantation facilitates preservation of residual hearing.
期刊介绍:
Official Journal of
European Union of Medical Specialists – ORL Section and Board
Official Journal of Confederation of European Oto-Rhino-Laryngology Head and Neck Surgery
"European Archives of Oto-Rhino-Laryngology" publishes original clinical reports and clinically relevant experimental studies, as well as short communications presenting new results of special interest. With peer review by a respected international editorial board and prompt English-language publication, the journal provides rapid dissemination of information by authors from around the world. This particular feature makes it the journal of choice for readers who want to be informed about the continuing state of the art concerning basic sciences and the diagnosis and management of diseases of the head and neck on an international level.
European Archives of Oto-Rhino-Laryngology was founded in 1864 as "Archiv für Ohrenheilkunde" by A. von Tröltsch, A. Politzer and H. Schwartze.