Evaluation of BI-RADS 3 Ultrasound Findings: the Frequency and Incidence of Malignant Lesions, and Tumor Size.

Q3 Medicine Acta medica academica Pub Date : 2025-02-25 DOI:10.5644/ama2006-124.467
Hanifa Fejzić, Svjetlana Mujagić, Belkisa Izić
{"title":"Evaluation of BI-RADS 3 Ultrasound Findings: the Frequency and Incidence of Malignant Lesions, and Tumor Size.","authors":"Hanifa Fejzić, Svjetlana Mujagić, Belkisa Izić","doi":"10.5644/ama2006-124.467","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The aim of the research was to determine the frequency of BI-RADS category 3 findings in ultrasound examinations in relation to the total number of patients, the frequency of malignant lesions, and their average size at the time of detection in BI-RADS 3 ultrasound findings.</p><p><strong>Patients and methods: </strong>A cross-sectional study was performed on 335 patients (aged 40-75 years) classified in BI-RADS category 3, at the Tuzla Breast Center, University Clinical Center, in the period from March 2017 to November 2020. A total of 13,760 ultrasound examinations were performed, using a Toshiba Xario 100 ultrasound machine with a 12 MHz linear probe. Patients were divided into premenopausal and postmenopausal groups, excluding patients with symptoms and those with previous breast cancer surgery. The images were stored using the Institution's Pictures Activation and Communication System.</p><p><strong>Results: </strong>BI-RADS category 3 findings accounted for 27% of all ultrasound examinations (N=3.715). Of these, 9.02% (N=335) underwent recommended short-term follow-up. Malignancy was identified in 1.49% of these cases (N=5), with an average tumor size of 13.6 mm at detection. The malignancy rate did not differ significantly between premenopausal and postmenopausal patients (P=0.412). The overall diagnostic yield for malignancy in BI-RADS 3 findings was low, but clinically significant.</p><p><strong>Conclusion: </strong>While the malignancy rate for BI-RADS category 3 findings is low (1.49%), careful monitoring and adherence to follow-up guideline are essential to balance early detection with avoidance of unnecessary biopsies and associated costs.</p>","PeriodicalId":38313,"journal":{"name":"Acta medica academica","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta medica academica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5644/ama2006-124.467","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The aim of the research was to determine the frequency of BI-RADS category 3 findings in ultrasound examinations in relation to the total number of patients, the frequency of malignant lesions, and their average size at the time of detection in BI-RADS 3 ultrasound findings.

Patients and methods: A cross-sectional study was performed on 335 patients (aged 40-75 years) classified in BI-RADS category 3, at the Tuzla Breast Center, University Clinical Center, in the period from March 2017 to November 2020. A total of 13,760 ultrasound examinations were performed, using a Toshiba Xario 100 ultrasound machine with a 12 MHz linear probe. Patients were divided into premenopausal and postmenopausal groups, excluding patients with symptoms and those with previous breast cancer surgery. The images were stored using the Institution's Pictures Activation and Communication System.

Results: BI-RADS category 3 findings accounted for 27% of all ultrasound examinations (N=3.715). Of these, 9.02% (N=335) underwent recommended short-term follow-up. Malignancy was identified in 1.49% of these cases (N=5), with an average tumor size of 13.6 mm at detection. The malignancy rate did not differ significantly between premenopausal and postmenopausal patients (P=0.412). The overall diagnostic yield for malignancy in BI-RADS 3 findings was low, but clinically significant.

Conclusion: While the malignancy rate for BI-RADS category 3 findings is low (1.49%), careful monitoring and adherence to follow-up guideline are essential to balance early detection with avoidance of unnecessary biopsies and associated costs.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Acta medica academica
Acta medica academica Medicine-Medicine (all)
CiteScore
1.90
自引率
0.00%
发文量
21
审稿时长
15 weeks
期刊最新文献
Evaluation of BI-RADS 3 Ultrasound Findings: the Frequency and Incidence of Malignant Lesions, and Tumor Size. Multimodal Anesthesia-Analgesia for Patients with Huntington's Disease: A Case Series. An Ectopic External Jugular Vein Draining into the Axillary Vein: a Rare Anatomical Variation with Clinical Implications. A Round Ligament Mesothelial Cyst Imitating an Inguinal Hernia in a Woman of Reproductive Age. HPV-Related Cancers in Bosnia and Herzegovina: A Comprehensive Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1