Comparison of accuracy between two different drill designs for static computer-assisted implant surgery: An in vitro study

IF 2 3区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Stomatology Oral and Maxillofacial Surgery Pub Date : 2025-09-01 Epub Date: 2025-02-23 DOI:10.1016/j.jormas.2025.102303
Mengyun Mao , Ting Wei , Mingxing Fan , Haisong Pan , Fudong Zhu
{"title":"Comparison of accuracy between two different drill designs for static computer-assisted implant surgery: An in vitro study","authors":"Mengyun Mao ,&nbsp;Ting Wei ,&nbsp;Mingxing Fan ,&nbsp;Haisong Pan ,&nbsp;Fudong Zhu","doi":"10.1016/j.jormas.2025.102303","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Although several different design methods have been proposed, limited research is available regarding how design features impact accuracy and performance. The purpose of this study was to compare the accuracy of implant site location between two different drilling systems for static computer-assisted implant surgery (sCAIS) in vitro study, each featuring a unique drill stabilization configuration.</div></div><div><h3>Materials and methods</h3><div>Sixty models were fabricated simulating a patient with maxillary partial tooth missing. Each model included two single-tooth gap (STG) situations; two extraction socket sites; and a distal extension situation. Experimental models were categorized into two distinct groups, group A: a sleeve-in-sleeve system with a metal sleeve embedded in the surgical guide; group B: an integrated sleeve-on-drill system without a metal sleeve. The deviations in shoulder, tip, depth, and angular were measured. Date were analyzed using the Scheirer-Ray-Hare test (<em>P</em> ≤ 0.05).</div></div><div><h3>Results</h3><div>The deviation of shoulder, tip and angular in group B were significantly lower than group A. When using an integrated sleeve-on-drill system, the remaining deviation values in extraction sockets were significantly higher than those in the STG situation and the distal extension situation, with the exception of depth deviation. However, there is no significant difference between STG situation and distal extension situation.</div></div><div><h3>Conclusion</h3><div>In comparison to the sleeve-in-sleeve system with a metal sleeve in the surgical guide, the accuracy of an integrated sleeve-on-drill system without a metal sleeve was higher. The accuracy of implantation in extracted sockets was significantly lower than that in healing sites.</div></div>","PeriodicalId":55993,"journal":{"name":"Journal of Stomatology Oral and Maxillofacial Surgery","volume":"126 4","pages":"Article 102303"},"PeriodicalIF":2.0000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Stomatology Oral and Maxillofacial Surgery","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468785525000916","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/23 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Although several different design methods have been proposed, limited research is available regarding how design features impact accuracy and performance. The purpose of this study was to compare the accuracy of implant site location between two different drilling systems for static computer-assisted implant surgery (sCAIS) in vitro study, each featuring a unique drill stabilization configuration.

Materials and methods

Sixty models were fabricated simulating a patient with maxillary partial tooth missing. Each model included two single-tooth gap (STG) situations; two extraction socket sites; and a distal extension situation. Experimental models were categorized into two distinct groups, group A: a sleeve-in-sleeve system with a metal sleeve embedded in the surgical guide; group B: an integrated sleeve-on-drill system without a metal sleeve. The deviations in shoulder, tip, depth, and angular were measured. Date were analyzed using the Scheirer-Ray-Hare test (P ≤ 0.05).

Results

The deviation of shoulder, tip and angular in group B were significantly lower than group A. When using an integrated sleeve-on-drill system, the remaining deviation values in extraction sockets were significantly higher than those in the STG situation and the distal extension situation, with the exception of depth deviation. However, there is no significant difference between STG situation and distal extension situation.

Conclusion

In comparison to the sleeve-in-sleeve system with a metal sleeve in the surgical guide, the accuracy of an integrated sleeve-on-drill system without a metal sleeve was higher. The accuracy of implantation in extracted sockets was significantly lower than that in healing sites.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
两种不同钻头设计在静态计算机辅助种植手术中的精度比较:一项体外研究。
背景:虽然提出了几种不同的设计方法,但关于设计特征如何影响精度和性能的研究有限。本研究的目的是比较两种不同的钻孔系统在静态计算机辅助种植手术(sCAIS)中植入体位置的准确性,每种系统都具有独特的钻头稳定配置。材料与方法:制作60个上颌部分牙缺失模型。每个模型包括两种单齿间隙(STG)情况;两个提取槽位;和远端伸展情况。实验模型分为两个不同的组,A组:一套套管系统,金属套管嵌入手术指南;B组:没有金属套的钻具套上系统。测量肩关节、针尖、深度和角度的偏差。数据采用Scheirer-Ray-Hare检验(P≤0.05)。结果:B组肩关节、尖端、角度偏差均显著低于a组。采用套上钻一体化系统时,除深度偏差外,拔牙槽内剩余偏差值均显著高于STG组和远端伸展组。而STG情况与远端伸展情况无显著性差异。结论:与带金属套的手术导向套中套系统相比,不带金属套的套中钻一体化系统的精度更高。拔除的牙槽种植的准确性明显低于愈合部位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Stomatology Oral and Maxillofacial Surgery
Journal of Stomatology Oral and Maxillofacial Surgery Surgery, Dentistry, Oral Surgery and Medicine, Otorhinolaryngology and Facial Plastic Surgery
CiteScore
2.30
自引率
9.10%
发文量
0
审稿时长
23 days
期刊最新文献
Improving autologous tooth transplantation: A novel approach using digital technology and a positioning adhesive guide Novel de novo CLCN7 mutation in refractory osteopetrosis-related osteomyelitis: A case report and multidisciplinary therapeutic dilemmas Use of unleavened bread to reduce the appearance of radiolucent areas associated with the palatoglossal air space in panoramic radiographs: A comparative study A 3D-printed craniofacial fracture library with QR-integrated pedagogical content: a technical note for maxillofacial trauma teaching Champions in the making? – The Journal of Stomatology, Oral and Maxillofacial Surgery in 2026
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1