Compliance with infection control practices among healthcare workers in radiology departments: a participant observation study and adenosine triphosphate assay evaluation of environmental cleanliness

IF 1.9 Q3 INFECTIOUS DISEASES Infection Prevention in Practice Pub Date : 2025-06-01 Epub Date: 2025-02-11 DOI:10.1016/j.infpip.2025.100441
Leonia Hiu Wan Lau , Fion Wai Fong Tse , Lorna Kwai Ping Suen , Simon Ching Lam
{"title":"Compliance with infection control practices among healthcare workers in radiology departments: a participant observation study and adenosine triphosphate assay evaluation of environmental cleanliness","authors":"Leonia Hiu Wan Lau ,&nbsp;Fion Wai Fong Tse ,&nbsp;Lorna Kwai Ping Suen ,&nbsp;Simon Ching Lam","doi":"10.1016/j.infpip.2025.100441","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Increased risk of healthcare-associated infections (HAIs) in radiology departments has been reported in recent years. Optimal infection control practices (ICPs) are the key to controlling HAIs, but few studies have investigated the ICP compliance of healthcare workers (HCWs) in radiology departments.</div></div><div><h3>Aim</h3><div>To assess the level of ICP compliance of HCWs in a radiology department.</div></div><div><h3>Methods</h3><div>A participant observation supplemented with adenosine triphosphate (ATP) bioluminescence assay evaluation of environmental cleanliness was conducted. More than 1000 hand hygiene (HH) opportunities and 960 opportunities for the other core ICP elements were observed in different study units of a radiology department. An online checklist powered by eRub was used to record the HCWs' ICP performance. A total of 125 environmental samples were collected for ATP assay evaluation.</div></div><div><h3>Results</h3><div>In the participants observation, the overall performance score was 41.4%. The lowest score was found in HH (10.4%), followed by use of personal protective equipment (29.4%) and gloves (68.2%). The HH performance was significantly associated with study units (χ<sup>2</sup> = 42.55, <em>P</em> &lt; 0.001), professional groups (χ<sup>2</sup> = 110.21, <em>P</em> &lt; 0.001), and patient-to-staff ratio (<em>F</em> = 8.76, <em>P</em> &lt; 0.001). With relative light units of ≤250 set as a pass benchmark, less than two-thirds of the environmental samples passed the ATP assay.</div></div><div><h3>Conclusion</h3><div>The overall ICP compliance among the HCWs in the radiology department was suboptimal. Revisions of current ICP guidelines and policies that are tailored to the setting-specific needs and barriers in radiology departments is necessary.</div></div>","PeriodicalId":33492,"journal":{"name":"Infection Prevention in Practice","volume":"7 2","pages":"Article 100441"},"PeriodicalIF":1.9000,"publicationDate":"2025-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infection Prevention in Practice","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590088925000058","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/11 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Increased risk of healthcare-associated infections (HAIs) in radiology departments has been reported in recent years. Optimal infection control practices (ICPs) are the key to controlling HAIs, but few studies have investigated the ICP compliance of healthcare workers (HCWs) in radiology departments.

Aim

To assess the level of ICP compliance of HCWs in a radiology department.

Methods

A participant observation supplemented with adenosine triphosphate (ATP) bioluminescence assay evaluation of environmental cleanliness was conducted. More than 1000 hand hygiene (HH) opportunities and 960 opportunities for the other core ICP elements were observed in different study units of a radiology department. An online checklist powered by eRub was used to record the HCWs' ICP performance. A total of 125 environmental samples were collected for ATP assay evaluation.

Results

In the participants observation, the overall performance score was 41.4%. The lowest score was found in HH (10.4%), followed by use of personal protective equipment (29.4%) and gloves (68.2%). The HH performance was significantly associated with study units (χ2 = 42.55, P < 0.001), professional groups (χ2 = 110.21, P < 0.001), and patient-to-staff ratio (F = 8.76, P < 0.001). With relative light units of ≤250 set as a pass benchmark, less than two-thirds of the environmental samples passed the ATP assay.

Conclusion

The overall ICP compliance among the HCWs in the radiology department was suboptimal. Revisions of current ICP guidelines and policies that are tailored to the setting-specific needs and barriers in radiology departments is necessary.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
放射科医护人员对感染控制措施的依从性:一项参与性观察研究和环境清洁度的三磷酸腺苷测定评价
背景:近年来,有报道称放射科的医疗保健相关感染(HAIs)风险增加。最佳感染控制措施(ICP)是控制HAIs的关键,但很少有研究调查放射科医护人员(HCWs)对ICP的依从性。目的评价某放射科医护人员对ICP的依从性。方法采用参与观察加三磷酸腺苷(ATP)生物发光法评价环境洁净度。在某放射科的不同研究单位观察到1000多个手部卫生(HH)机会和960多个其他核心ICP要素的机会。使用由eRub提供支持的在线检查表记录医护人员的ICP表现。共收集125份环境样品进行ATP测定评价。结果在参与者观察中,整体表现得分为41.4%。HH(10.4%)得分最低,其次是使用个人防护装备(29.4%)和手套(68.2%)。HH表现与研究单位显著相关(χ2 = 42.55, P <;0.001),专业组(χ2 = 110.21, P <;0.001),患者与工作人员比率(F = 8.76, P <;0.001)。以相对光单位≤250作为通过基准,不到三分之二的环境样品通过ATP测定。结论放射科医护人员总体ICP依从性不理想。有必要修订现行的ICP指南和政策,以适应放射科的具体需要和障碍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Infection Prevention in Practice
Infection Prevention in Practice Medicine-Public Health, Environmental and Occupational Health
CiteScore
4.80
自引率
0.00%
发文量
58
审稿时长
61 days
期刊最新文献
Effect of individual feedback on hand hygiene compliance in nursing homes Neonates at a risk of hospital-acquired ESKAPEE infection despite implementation of infection prevention protocols Effect of bathing with 2% chlorhexidine gluconate every other day on healthcare-associated infections in the medical intensive care unit Decontamination of environmental surfaces in hospitals to reduce hospital-acquired infections: a systematic review Evaluation of endoscopic processing on the potential for Clostridiodes difficile transmission
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1