Dose comparison between hybrid volumetric modulated arc therapy, volumetric modulated arc therapy, and three-dimensional conformal radiotherapy for breast/chest wall irradiation, including regional lymph node irradiation using deep inspiration breath-hold technique

IF 1.5 4区 医学 Q4 ONCOLOGY Cancer Radiotherapie Pub Date : 2025-02-01 DOI:10.1016/j.canrad.2025.104589
Zainab Alsaihaty , Wamied Abdel-Rahman , Karunakaran Balaji , Mashaal Alkhaldi , Abdulraouf Alghufaili , Shama Alghadban , Hala El Lathy , Hanani Abdul Manan , Akmal Sabarudin , Noorazrul Yahya
{"title":"Dose comparison between hybrid volumetric modulated arc therapy, volumetric modulated arc therapy, and three-dimensional conformal radiotherapy for breast/chest wall irradiation, including regional lymph node irradiation using deep inspiration breath-hold technique","authors":"Zainab Alsaihaty ,&nbsp;Wamied Abdel-Rahman ,&nbsp;Karunakaran Balaji ,&nbsp;Mashaal Alkhaldi ,&nbsp;Abdulraouf Alghufaili ,&nbsp;Shama Alghadban ,&nbsp;Hala El Lathy ,&nbsp;Hanani Abdul Manan ,&nbsp;Akmal Sabarudin ,&nbsp;Noorazrul Yahya","doi":"10.1016/j.canrad.2025.104589","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><div>Breast radiation treatment has been linked to complications such as pneumonitis and cardiac toxicity, necessitating dose optimization. This study aims to determine the optimal integration plan of volumetric modulated arc therapy (VMAT) and three-dimensional conformal radiotherapy (3DCRT) in a deep inspiration breath-hold regimen.</div></div><div><h3>Materials and methods</h3><div>CT imaging data from twenty patients with breast or chest wall cancer, either right or left-sided, and with supraclavicular and internal mammary chain lymph nodes were retrieved. The CT data planned with a hybrid VMAT of three different weighting proportions: 30 % using 3DCRT and 70 % using VMAT, 50 % using 3DCRT and 50 % using VMAT, and 70% using 3DCRT and 30 % using VMAT and compared with full 3DCRT and full VMAT plan (classic and five arc design).</div></div><div><h3>Results</h3><div>The homogeneity and conformity indices were better in the hybrid VMAT plans than in plans using VMAT or 3DCRT alone (<em>P</em> <!-->&lt;<!--> <!-->0.005). Results of all hybrid VMAT plans showed a considerable drop of volumes receiving more than 4<!--> <!-->Gy, 8<!--> <!-->Gy or 16<!--> <!-->Gy in the ipsilateral lung compared to the full VMAT plan (<em>P</em> <!-->&lt;<!--> <!-->0.001). There was a noticeable decrease in the mean dose to the heart and the dose in 5% of the contralateral breast in the plan using 70 % 3DCRT and 30 % VMAT compared to full VMAT (<em>P</em> <!-->&lt;<!--> <!-->0.001). The plan using 70 % 3DCRT and 30% VMAT achieved a balance between the target and surrounding areas, compared to using only 3DCRT or VMAT.</div></div><div><h3>Conclusion</h3><div>A hybrid plan using 70 % 3DCRT contribution achieved a balanced outcome for breast or chest wall irradiation, considering both planning target volume and organs at risk. Utilizing our VMAT arc design, incorporating one shortened arc can significantly reduce doses to organs at risk further. It is important to consider the patient's anatomy when making this decision.</div></div>","PeriodicalId":9504,"journal":{"name":"Cancer Radiotherapie","volume":"29 1","pages":"Article 104589"},"PeriodicalIF":1.5000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cancer Radiotherapie","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1278321825000058","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

Breast radiation treatment has been linked to complications such as pneumonitis and cardiac toxicity, necessitating dose optimization. This study aims to determine the optimal integration plan of volumetric modulated arc therapy (VMAT) and three-dimensional conformal radiotherapy (3DCRT) in a deep inspiration breath-hold regimen.

Materials and methods

CT imaging data from twenty patients with breast or chest wall cancer, either right or left-sided, and with supraclavicular and internal mammary chain lymph nodes were retrieved. The CT data planned with a hybrid VMAT of three different weighting proportions: 30 % using 3DCRT and 70 % using VMAT, 50 % using 3DCRT and 50 % using VMAT, and 70% using 3DCRT and 30 % using VMAT and compared with full 3DCRT and full VMAT plan (classic and five arc design).

Results

The homogeneity and conformity indices were better in the hybrid VMAT plans than in plans using VMAT or 3DCRT alone (P < 0.005). Results of all hybrid VMAT plans showed a considerable drop of volumes receiving more than 4 Gy, 8 Gy or 16 Gy in the ipsilateral lung compared to the full VMAT plan (P < 0.001). There was a noticeable decrease in the mean dose to the heart and the dose in 5% of the contralateral breast in the plan using 70 % 3DCRT and 30 % VMAT compared to full VMAT (P < 0.001). The plan using 70 % 3DCRT and 30% VMAT achieved a balance between the target and surrounding areas, compared to using only 3DCRT or VMAT.

Conclusion

A hybrid plan using 70 % 3DCRT contribution achieved a balanced outcome for breast or chest wall irradiation, considering both planning target volume and organs at risk. Utilizing our VMAT arc design, incorporating one shortened arc can significantly reduce doses to organs at risk further. It is important to consider the patient's anatomy when making this decision.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Cancer Radiotherapie
Cancer Radiotherapie 医学-核医学
CiteScore
2.20
自引率
23.10%
发文量
129
审稿时长
63 days
期刊介绍: Cancer/radiothérapie se veut d''abord et avant tout un organe francophone de publication des travaux de recherche en radiothérapie. La revue a pour objectif de diffuser les informations majeures sur les travaux de recherche en cancérologie et tout ce qui touche de près ou de loin au traitement du cancer par les radiations : technologie, radiophysique, radiobiologie et radiothérapie clinique.
期刊最新文献
Long-term cardiac mortality in patients treated with radiation for gastric mucosa-associated lymphoid tissue lymphoma Dose comparison between hybrid volumetric modulated arc therapy, volumetric modulated arc therapy, and three-dimensional conformal radiotherapy for breast/chest wall irradiation, including regional lymph node irradiation using deep inspiration breath-hold technique Cyberneo trial investigating the efficacy of stereotactic radiotherapy combined to neoadjuvant chemotherapy for locally advanced breast cancer: 14-years follow-up results Exploring treatment complexity in maxillary ameloblastoma: A case study on the efficacy of radiotherapy with transcriptomic and literature insights Does prior radiotherapy impact the acute cellular liver graft rejection?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1