Relationship between point-of-care ultrasound venous congestion assessment parameters, intravenous pressure, and venous return: a post-hoc analysis of a prospective cohort study.

IF 3.4 Q2 Medicine Ultrasound Journal Pub Date : 2025-02-27 DOI:10.1186/s13089-025-00421-9
Martin Ruste, Quentin Delas, Rehane Reskot, Jean-Luc Fellahi, Matthias Jacquet-Lagrèze
{"title":"Relationship between point-of-care ultrasound venous congestion assessment parameters, intravenous pressure, and venous return: a post-hoc analysis of a prospective cohort study.","authors":"Martin Ruste, Quentin Delas, Rehane Reskot, Jean-Luc Fellahi, Matthias Jacquet-Lagrèze","doi":"10.1186/s13089-025-00421-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>A recent study suggested that point-of-care ultrasound (POCUS) venous congestion assessment poorly describes the changes in venous return during a fluid challenge. The aim of the present study was to explore the relationship between POCUS venous congestion assessment parameters and the determinants of venous return in steady state and during a fluid challenge.</p><p><strong>Methods: </strong>This study is a post-hoc analysis of a single-centre prospective cohort study of patients presenting acute circulatory failure and venous congestion. The protocol consisted in a fluid administration of 4mL/kg over five minutes, just preceded and followed by the acquisition of haemodynamic data and POCUS venous congestion assessment parameters (VExUS score and portal pulsatility index, PPi). Venous return (dVR) was defined as the difference between mean systemic filling pressure analogue estimated by the mathematical approach of Parkin and Leaning (Pmsa) and central venous pressure (CVP). Relationships between Pmsa, CVP, dVR, and VExUS score and PPi were analysed using linear regression and Jonckheere-Terpstra test for trend.</p><p><strong>Results: </strong>Thirty-two patients were included in the analysis. Fluid challenge induced a significant increase in CVP, Pmsa, dVR, and VExUS score. In steady state, there was a significant association of VExUS score and PPi with CVP (P-value = 0.006 and 0.002, respectively) and Pmsa (P-value = 0.004 and 0.003, respectively) but not with dVR (P-value = 0.943 and 0.408, respectively). The variations induced by fluid challenge in CVP, Pmsa and dVR were not associated with variations in PPi (P-value = 0.844, 0.912 and 0.716, respectively). Patients without VExUS score increase during the fluid challenge presented a higher increase in Pmsa than patients with an increase in VExUS score.</p><p><strong>Conclusion: </strong>In steady state, POCUS venous congestion assessment parameters are associated with CVP and Pmsa but not with dVR. After fluid administration, changes in POCUS venous congestion assessment parameters were not associated with changes in CVP, Pmsa, and dVR.</p>","PeriodicalId":36911,"journal":{"name":"Ultrasound Journal","volume":"17 1","pages":"15"},"PeriodicalIF":3.4000,"publicationDate":"2025-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11867982/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s13089-025-00421-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: A recent study suggested that point-of-care ultrasound (POCUS) venous congestion assessment poorly describes the changes in venous return during a fluid challenge. The aim of the present study was to explore the relationship between POCUS venous congestion assessment parameters and the determinants of venous return in steady state and during a fluid challenge.

Methods: This study is a post-hoc analysis of a single-centre prospective cohort study of patients presenting acute circulatory failure and venous congestion. The protocol consisted in a fluid administration of 4mL/kg over five minutes, just preceded and followed by the acquisition of haemodynamic data and POCUS venous congestion assessment parameters (VExUS score and portal pulsatility index, PPi). Venous return (dVR) was defined as the difference between mean systemic filling pressure analogue estimated by the mathematical approach of Parkin and Leaning (Pmsa) and central venous pressure (CVP). Relationships between Pmsa, CVP, dVR, and VExUS score and PPi were analysed using linear regression and Jonckheere-Terpstra test for trend.

Results: Thirty-two patients were included in the analysis. Fluid challenge induced a significant increase in CVP, Pmsa, dVR, and VExUS score. In steady state, there was a significant association of VExUS score and PPi with CVP (P-value = 0.006 and 0.002, respectively) and Pmsa (P-value = 0.004 and 0.003, respectively) but not with dVR (P-value = 0.943 and 0.408, respectively). The variations induced by fluid challenge in CVP, Pmsa and dVR were not associated with variations in PPi (P-value = 0.844, 0.912 and 0.716, respectively). Patients without VExUS score increase during the fluid challenge presented a higher increase in Pmsa than patients with an increase in VExUS score.

Conclusion: In steady state, POCUS venous congestion assessment parameters are associated with CVP and Pmsa but not with dVR. After fluid administration, changes in POCUS venous congestion assessment parameters were not associated with changes in CVP, Pmsa, and dVR.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Ultrasound Journal
Ultrasound Journal Health Professions-Radiological and Ultrasound Technology
CiteScore
6.80
自引率
2.90%
发文量
45
审稿时长
22 weeks
期刊最新文献
Ultrasound-guided vs. Non-ultrasound-guided femoral artery puncture techniques: a comprehensive systematic review and meta-analysis. Assess, improve, detect, guide: a narrative review and proposal for a standardized protocol for prehospital transesophageal echocardiography during out-of-hospital cardiac arrest. Knowledge and utilization of obstetric ultrasound and associated factors among pregnant mother in Africa: a systematic review and meta-analysis. Venous excess ultrasound score association with acute kidney injury in critically ill patients: a systematic review and meta-analysis of observational studies. Relationship between point-of-care ultrasound venous congestion assessment parameters, intravenous pressure, and venous return: a post-hoc analysis of a prospective cohort study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1