Zhifang Xue, Shuao Zhao, Hao Li, Rongzhao Gu, Rong Hua, Xianliang Yan
{"title":"[Design and application of a cardiopulmonary resuscitation compression depth limiting device].","authors":"Zhifang Xue, Shuao Zhao, Hao Li, Rongzhao Gu, Rong Hua, Xianliang Yan","doi":"10.3760/cma.j.cn121430-20240903-00743","DOIUrl":null,"url":null,"abstract":"<p><p>During cardiopulmonary resuscitation (CPR), the depth of compression is a critical factor affecting the effectiveness of the rescue and the patient's prognosis. However, it is difficult to master the correct compression depth in manual CPR. If the compression depth is too deep, it may cause rib fractures, while insufficient compression depth may fail to establish effective circulation. Although most existing manual CPR compression depth control devices can indicate the depth but lack direct limiting functions. Against this background, led by a team of faculty and students from the Department of Emergency and Rescue Medicine at Xuzhou Medical University, on the basis of the development of a portable CPR protection device (National Invention Patent of China, patent number: ZL 2021 1 0309001.4), the device's compression depth limiting performance was further expanded, and then a new type of CPR compression depth limiting device suitable for different body types was developed. This device has applied for a National Invention Patent of China (patent application number: ZL 2023 1 0644910.2) and has been granted a National Utility Model Patent of China (patent number: ZL 2023 2 1384853.0). The device consists of a horizontal support beam, a vertical sliding beam, a guide block, a rotating shaft, a rotating arm, a limit slider and a limit pin. The horizontal support beams of the two limit devices are fixed horizontally to the horizontal side beams of the portable CPR protection device by bolts, and the connecting arms at the bottom of the vertical sliding beams are fixedly connected with the pressing mechanism, so that precise control of the pressing depth in CPR operation can be realized according to the patient's body size by the mechanical linkage of the vertical sliding beams and the rotating arms, as well as by the blocking and limiting effect of the rotating arms and the guiding blocks on the limiting sliders. It can prevent the occurrence of complications such as chest wall fractures, and thereby increase the success rate of manual CPR, and its structure is simple, low-cost, and suitable for social popularization.</p>","PeriodicalId":24079,"journal":{"name":"Zhonghua wei zhong bing ji jiu yi xue","volume":"37 2","pages":"180-182"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhonghua wei zhong bing ji jiu yi xue","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3760/cma.j.cn121430-20240903-00743","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
During cardiopulmonary resuscitation (CPR), the depth of compression is a critical factor affecting the effectiveness of the rescue and the patient's prognosis. However, it is difficult to master the correct compression depth in manual CPR. If the compression depth is too deep, it may cause rib fractures, while insufficient compression depth may fail to establish effective circulation. Although most existing manual CPR compression depth control devices can indicate the depth but lack direct limiting functions. Against this background, led by a team of faculty and students from the Department of Emergency and Rescue Medicine at Xuzhou Medical University, on the basis of the development of a portable CPR protection device (National Invention Patent of China, patent number: ZL 2021 1 0309001.4), the device's compression depth limiting performance was further expanded, and then a new type of CPR compression depth limiting device suitable for different body types was developed. This device has applied for a National Invention Patent of China (patent application number: ZL 2023 1 0644910.2) and has been granted a National Utility Model Patent of China (patent number: ZL 2023 2 1384853.0). The device consists of a horizontal support beam, a vertical sliding beam, a guide block, a rotating shaft, a rotating arm, a limit slider and a limit pin. The horizontal support beams of the two limit devices are fixed horizontally to the horizontal side beams of the portable CPR protection device by bolts, and the connecting arms at the bottom of the vertical sliding beams are fixedly connected with the pressing mechanism, so that precise control of the pressing depth in CPR operation can be realized according to the patient's body size by the mechanical linkage of the vertical sliding beams and the rotating arms, as well as by the blocking and limiting effect of the rotating arms and the guiding blocks on the limiting sliders. It can prevent the occurrence of complications such as chest wall fractures, and thereby increase the success rate of manual CPR, and its structure is simple, low-cost, and suitable for social popularization.