{"title":"[Design and application of a cardiopulmonary resuscitation compression depth limiting device].","authors":"Zhifang Xue, Shuao Zhao, Hao Li, Rongzhao Gu, Rong Hua, Xianliang Yan","doi":"10.3760/cma.j.cn121430-20240903-00743","DOIUrl":null,"url":null,"abstract":"<p><p>During cardiopulmonary resuscitation (CPR), the depth of compression is a critical factor affecting the effectiveness of the rescue and the patient's prognosis. However, it is difficult to master the correct compression depth in manual CPR. If the compression depth is too deep, it may cause rib fractures, while insufficient compression depth may fail to establish effective circulation. Although most existing manual CPR compression depth control devices can indicate the depth but lack direct limiting functions. Against this background, led by a team of faculty and students from the Department of Emergency and Rescue Medicine at Xuzhou Medical University, on the basis of the development of a portable CPR protection device (National Invention Patent of China, patent number: ZL 2021 1 0309001.4), the device's compression depth limiting performance was further expanded, and then a new type of CPR compression depth limiting device suitable for different body types was developed. This device has applied for a National Invention Patent of China (patent application number: ZL 2023 1 0644910.2) and has been granted a National Utility Model Patent of China (patent number: ZL 2023 2 1384853.0). The device consists of a horizontal support beam, a vertical sliding beam, a guide block, a rotating shaft, a rotating arm, a limit slider and a limit pin. The horizontal support beams of the two limit devices are fixed horizontally to the horizontal side beams of the portable CPR protection device by bolts, and the connecting arms at the bottom of the vertical sliding beams are fixedly connected with the pressing mechanism, so that precise control of the pressing depth in CPR operation can be realized according to the patient's body size by the mechanical linkage of the vertical sliding beams and the rotating arms, as well as by the blocking and limiting effect of the rotating arms and the guiding blocks on the limiting sliders. It can prevent the occurrence of complications such as chest wall fractures, and thereby increase the success rate of manual CPR, and its structure is simple, low-cost, and suitable for social popularization.</p>","PeriodicalId":24079,"journal":{"name":"Zhonghua wei zhong bing ji jiu yi xue","volume":"37 2","pages":"180-182"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhonghua wei zhong bing ji jiu yi xue","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3760/cma.j.cn121430-20240903-00743","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

During cardiopulmonary resuscitation (CPR), the depth of compression is a critical factor affecting the effectiveness of the rescue and the patient's prognosis. However, it is difficult to master the correct compression depth in manual CPR. If the compression depth is too deep, it may cause rib fractures, while insufficient compression depth may fail to establish effective circulation. Although most existing manual CPR compression depth control devices can indicate the depth but lack direct limiting functions. Against this background, led by a team of faculty and students from the Department of Emergency and Rescue Medicine at Xuzhou Medical University, on the basis of the development of a portable CPR protection device (National Invention Patent of China, patent number: ZL 2021 1 0309001.4), the device's compression depth limiting performance was further expanded, and then a new type of CPR compression depth limiting device suitable for different body types was developed. This device has applied for a National Invention Patent of China (patent application number: ZL 2023 1 0644910.2) and has been granted a National Utility Model Patent of China (patent number: ZL 2023 2 1384853.0). The device consists of a horizontal support beam, a vertical sliding beam, a guide block, a rotating shaft, a rotating arm, a limit slider and a limit pin. The horizontal support beams of the two limit devices are fixed horizontally to the horizontal side beams of the portable CPR protection device by bolts, and the connecting arms at the bottom of the vertical sliding beams are fixedly connected with the pressing mechanism, so that precise control of the pressing depth in CPR operation can be realized according to the patient's body size by the mechanical linkage of the vertical sliding beams and the rotating arms, as well as by the blocking and limiting effect of the rotating arms and the guiding blocks on the limiting sliders. It can prevent the occurrence of complications such as chest wall fractures, and thereby increase the success rate of manual CPR, and its structure is simple, low-cost, and suitable for social popularization.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Zhonghua wei zhong bing ji jiu yi xue
Zhonghua wei zhong bing ji jiu yi xue Medicine-Critical Care and Intensive Care Medicine
CiteScore
1.00
自引率
0.00%
发文量
42
期刊最新文献
[Autophagy reduces bacterial translocation by regulating intestinal mucosal oxidative stress]. [Current practice, prognostic risk factors and management strategies of pre-hospital extracorporeal cardiopulmonary resuscitation in China]. [Current situation investigation and analysis of influencing factors on the long-term quality of life of cured and discharged patients with severe acute pancreatitis]. [Design and application of a cardiopulmonary resuscitation compression depth limiting device]. [Design and application of an intelligent temperature-controlled peritoneal dialysis belt].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1