An improved thermal analysis method for vapor-cooled current leads considering convective heat transfer efficiency

IF 1.8 3区 工程技术 Q3 PHYSICS, APPLIED Cryogenics Pub Date : 2025-02-28 DOI:10.1016/j.cryogenics.2025.104052
Yingjie Tong, Ying Xu, Wenze Si, Dazhi Li, Yunshu Zhou, Li Ren, Jin Shi
{"title":"An improved thermal analysis method for vapor-cooled current leads considering convective heat transfer efficiency","authors":"Yingjie Tong,&nbsp;Ying Xu,&nbsp;Wenze Si,&nbsp;Dazhi Li,&nbsp;Yunshu Zhou,&nbsp;Li Ren,&nbsp;Jin Shi","doi":"10.1016/j.cryogenics.2025.104052","DOIUrl":null,"url":null,"abstract":"<div><div>As an important part of superconducting devices, the heat leakage of current leads directly affects the overall heat load of the cryogenic system. Therefore, the design of low heat leakage current leads is one of the most important issues in system design of superconducting devices. Vapor-cooled current leads (VCCL) are widely used in various superconducting devices because they have lower heat leakage compared with conduction-cooled current leads, and smaller consumption of cooling gas and higher economy compared with gas-cooled current leads. In this paper, an improved thermal analysis method for solving the heat leakage, temperature distribution and heat transfer efficiency of VCCL is proposed, which has a great advantage in terms of time-consumption and convergence while guaranteeing accuracy in comparison to conventional finite element method. Firstly, based on the heat balance equation of VCCL, the relationship of the heat transfer efficiency and convective heat transfer coefficient between VCCL and cooling gas is clarified. Subsequently, the formula to calculate the heat transfer efficiency of VCCL is derived according to heat transfer and fluid dynamics. Then, a thermal analysis method for VCCL based on iterative algorithm is put forward. Finally, the feasibility of the thermal analysis method is verified by finite element model based on COMSOL, which has been proved to be correct by experimental results in existing literature. The results indicate that for several VCCLs with typical structures, the calculation differences of heat leakage between the thermal analysis method proposed in this paper and COMSOL are all within 5 % and the calculation differences of temperature distribution are all within 10 K. However, in terms of time-consumption and convergence, the thermal analysis method proposed in this paper has a significant advantage, especially for VCCLs with complex structures.</div></div>","PeriodicalId":10812,"journal":{"name":"Cryogenics","volume":"147 ","pages":"Article 104052"},"PeriodicalIF":1.8000,"publicationDate":"2025-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cryogenics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S001122752500030X","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
引用次数: 0

Abstract

As an important part of superconducting devices, the heat leakage of current leads directly affects the overall heat load of the cryogenic system. Therefore, the design of low heat leakage current leads is one of the most important issues in system design of superconducting devices. Vapor-cooled current leads (VCCL) are widely used in various superconducting devices because they have lower heat leakage compared with conduction-cooled current leads, and smaller consumption of cooling gas and higher economy compared with gas-cooled current leads. In this paper, an improved thermal analysis method for solving the heat leakage, temperature distribution and heat transfer efficiency of VCCL is proposed, which has a great advantage in terms of time-consumption and convergence while guaranteeing accuracy in comparison to conventional finite element method. Firstly, based on the heat balance equation of VCCL, the relationship of the heat transfer efficiency and convective heat transfer coefficient between VCCL and cooling gas is clarified. Subsequently, the formula to calculate the heat transfer efficiency of VCCL is derived according to heat transfer and fluid dynamics. Then, a thermal analysis method for VCCL based on iterative algorithm is put forward. Finally, the feasibility of the thermal analysis method is verified by finite element model based on COMSOL, which has been proved to be correct by experimental results in existing literature. The results indicate that for several VCCLs with typical structures, the calculation differences of heat leakage between the thermal analysis method proposed in this paper and COMSOL are all within 5 % and the calculation differences of temperature distribution are all within 10 K. However, in terms of time-consumption and convergence, the thermal analysis method proposed in this paper has a significant advantage, especially for VCCLs with complex structures.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Cryogenics
Cryogenics 物理-热力学
CiteScore
3.80
自引率
9.50%
发文量
0
审稿时长
2.1 months
期刊介绍: Cryogenics is the world''s leading journal focusing on all aspects of cryoengineering and cryogenics. Papers published in Cryogenics cover a wide variety of subjects in low temperature engineering and research. Among the areas covered are: - Applications of superconductivity: magnets, electronics, devices - Superconductors and their properties - Properties of materials: metals, alloys, composites, polymers, insulations - New applications of cryogenic technology to processes, devices, machinery - Refrigeration and liquefaction technology - Thermodynamics - Fluid properties and fluid mechanics - Heat transfer - Thermometry and measurement science - Cryogenics in medicine - Cryoelectronics
期刊最新文献
Influence of cryogenic temperatures on DC surface flashover characteristics of BNNS-based epoxy nanocomposites An improved thermal analysis method for vapor-cooled current leads considering convective heat transfer efficiency Modelling the thermal buffer behavior of JT-60SA in case of pulsed heat loads Liquid nitrogen spray injection for direct-contact freeze concentration applications Differentiated fracture behaviors of a spray-formed Al-Cu-Li alloy under various heat treatments at liquid nitrogen temperature
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1