Development of a point-of-care testing (POCT)-use paper-based device for recombinase polymerase amplification (RPA)-based bioassays-: Demonstration of the detection of Neisseria gonorrhoeae

IF 7.6 Q1 BIOTECHNOLOGY & APPLIED MICROBIOLOGY Sensors and Actuators Reports Pub Date : 2025-02-25 DOI:10.1016/j.snr.2025.100307
Po-Yu Chu , Po-Shuan Huang , Chih-Yu Chen , Kun-Yu Tsai , Shu-Ying Chiu , Le-Wei Fan , Yu-Chen Cheng , Chi-Jui Lin , Chia-Hsun Hsieh , Min-Hsien Wu
{"title":"Development of a point-of-care testing (POCT)-use paper-based device for recombinase polymerase amplification (RPA)-based bioassays-: Demonstration of the detection of Neisseria gonorrhoeae","authors":"Po-Yu Chu ,&nbsp;Po-Shuan Huang ,&nbsp;Chih-Yu Chen ,&nbsp;Kun-Yu Tsai ,&nbsp;Shu-Ying Chiu ,&nbsp;Le-Wei Fan ,&nbsp;Yu-Chen Cheng ,&nbsp;Chi-Jui Lin ,&nbsp;Chia-Hsun Hsieh ,&nbsp;Min-Hsien Wu","doi":"10.1016/j.snr.2025.100307","DOIUrl":null,"url":null,"abstract":"<div><div>The point of care test (POCT) of pathogens is critical for various applications. Nevertheless, the current immunological- or polymerase chain reaction (PCR)-based assays might not meet the requirements for POCT (e.g., ASSURED: affordable, sensitive, specific, user-friendly, rapid, equipment-free, and delivered proposed by the World Health Organization). To address this issue, this study proposed a paper-based device within which the functions of nucleic acid isolation, recombinase polymerase amplification (RPA)-based nucleic acid amplification, and lateral flow immunoassays were integrated. For RPA, a disposable hand warmer capable of providing 45 °C temperature was attached underneath the paper-based device for achieving equipment-free bioassays. Unlike the other paper-based devices, the presented device maintains the working area for reagent loading at a fixed area to largely simplify the operation procedures making a bioassay user-friendly. In this study, its working performances were evaluated. Results demonstrated that the detection sensitivity was 10 copies of genomic DNA under 10 min RPA reaction time, which was 10 times lower than that (100 copies) based on the conventional RPA-based assays. Also, its application for the detection of <em>Neisseria gonorrhoeae</em> in urine was successfully demonstrated. Results revealed it was able to detect <em>N. gonorrhoeae</em> with detection sensitivity of 1 CFU/ml. Overall, this study presented a paper-based device capable of performing isothermal nucleic acid amplification tests in a user-friendly, low-cost, equipment-free, rapid (30- 35 min) and high detection sensitivity (10 copies of DNA, or 1 CFU/ml of bacteria) manner. These features make it suitable for the applications in POCT, home care, or resource-limited regions.</div></div>","PeriodicalId":426,"journal":{"name":"Sensors and Actuators Reports","volume":"9 ","pages":"Article 100307"},"PeriodicalIF":7.6000,"publicationDate":"2025-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666053925000268","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The point of care test (POCT) of pathogens is critical for various applications. Nevertheless, the current immunological- or polymerase chain reaction (PCR)-based assays might not meet the requirements for POCT (e.g., ASSURED: affordable, sensitive, specific, user-friendly, rapid, equipment-free, and delivered proposed by the World Health Organization). To address this issue, this study proposed a paper-based device within which the functions of nucleic acid isolation, recombinase polymerase amplification (RPA)-based nucleic acid amplification, and lateral flow immunoassays were integrated. For RPA, a disposable hand warmer capable of providing 45 °C temperature was attached underneath the paper-based device for achieving equipment-free bioassays. Unlike the other paper-based devices, the presented device maintains the working area for reagent loading at a fixed area to largely simplify the operation procedures making a bioassay user-friendly. In this study, its working performances were evaluated. Results demonstrated that the detection sensitivity was 10 copies of genomic DNA under 10 min RPA reaction time, which was 10 times lower than that (100 copies) based on the conventional RPA-based assays. Also, its application for the detection of Neisseria gonorrhoeae in urine was successfully demonstrated. Results revealed it was able to detect N. gonorrhoeae with detection sensitivity of 1 CFU/ml. Overall, this study presented a paper-based device capable of performing isothermal nucleic acid amplification tests in a user-friendly, low-cost, equipment-free, rapid (30- 35 min) and high detection sensitivity (10 copies of DNA, or 1 CFU/ml of bacteria) manner. These features make it suitable for the applications in POCT, home care, or resource-limited regions.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于重组酶聚合酶扩增(RPA)的生物测定的即时检测(POCT)纸质设备的开发——淋病奈瑟菌检测的演示
病原体的护理点试验(POCT)在各种应用中至关重要。然而,目前基于免疫学或聚合酶链反应(PCR)的检测方法可能无法满足POCT的要求(例如,确保:负担得起、敏感、特异性、用户友好、快速、无设备,并由世界卫生组织提出)。为了解决这一问题,本研究提出了一种集核酸分离、基于重组酶聚合酶扩增(RPA)的核酸扩增和侧流免疫测定功能于一体的纸质检测装置。对于RPA,可提供45°C温度的一次性暖手器连接在纸质设备下方,以实现无设备生物分析。与其他基于纸张的设备不同,本发明的设备将试剂装载工作区维持在固定区域,从而大大简化了操作程序,使生物测定对用户友好。本研究对其工作性能进行了评价。结果表明,在10 min RPA反应时间下,检测灵敏度为10拷贝基因组DNA,比传统RPA检测方法(100拷贝)低10倍。并成功地应用于尿中淋病奈瑟菌的检测。结果显示,该方法可检出淋病奈瑟菌,检测灵敏度为1 CFU/ml。总的来说,本研究提出了一种基于纸张的设备,能够以用户友好、低成本、无设备、快速(30- 35分钟)和高检测灵敏度(10拷贝DNA或1 CFU/ml细菌)的方式进行等温核酸扩增试验。这些特性使其适合POCT、家庭护理或资源有限地区的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
9.60
自引率
0.00%
发文量
60
审稿时长
49 days
期刊介绍: Sensors and Actuators Reports is a peer-reviewed open access journal launched out from the Sensors and Actuators journal family. Sensors and Actuators Reports is dedicated to publishing new and original works in the field of all type of sensors and actuators, including bio-, chemical-, physical-, and nano- sensors and actuators, which demonstrates significant progress beyond the current state of the art. The journal regularly publishes original research papers, reviews, and short communications. For research papers and short communications, the journal aims to publish the new and original work supported by experimental results and as such purely theoretical works are not accepted.
期刊最新文献
Autonomous stretchable sensor array with low-power wireless readout for spatial pH mapping Thermal lamination and laser cut (TLLC) method for enclosed Micro-fluidic paper analytical devices (μPADs) by controlled ablation Biosensors for epigenetic biomarker detection: Recent advances and perspectives Steerable thin-film electrode array for cochlear implantation: design and development for future atraumatic insertion DNA-functionalized nanomaterials for optical biosensors: Mechanisms, applications, and design perspectives
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1