Dedicated 3D-Printed Radioactive Phantoms With ¹⁸F-FDG for Ultrahigh-Resolution PET

IF 4.6 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING IEEE Transactions on Radiation and Plasma Medical Sciences Pub Date : 2024-11-04 DOI:10.1109/TRPMS.2024.3483233
Ezzat Elmoujarkach;Steven Seeger;Luise Morgner;Fabian Schmidt;Julia G. Mannheim;Christian L. Schmidt;Magdalena Rafecas
{"title":"Dedicated 3D-Printed Radioactive Phantoms With ¹⁸F-FDG for Ultrahigh-Resolution PET","authors":"Ezzat Elmoujarkach;Steven Seeger;Luise Morgner;Fabian Schmidt;Julia G. Mannheim;Christian L. Schmidt;Magdalena Rafecas","doi":"10.1109/TRPMS.2024.3483233","DOIUrl":null,"url":null,"abstract":"This study explores the potential of digital light processing to 3-D print radioactive phantoms for high-resolution positron emission tomography (PET). Using a slightly modified desktop 3-D printer and mixtures of 18F-FDG (T1/2: 109.8 min) and photopolymer resin, we have printed standardized and custom radioactive objects designed for ultrahigh-resolution PET, also as a first step toward complex geometries. The phantoms were: a flood source to assess uniformity, a two-point phantom for spatial resolution assessment, a multiline phantom for validating submillimeter printing resolution, a fish-like phantom with different activity concentrations, and a 50%-downscaled micro-PET image quality phantom (National Electrical Manufacturers Association NU 4-2008). Positron range effects were examined on the latter using a removable cover. The evaluation relied on planar images from a phosphor imager and tomographic images from a commercial small animal PET scanner. We were able to print radioactive uniform distributions with relative standard deviation below 4.5% and structures as small as 0.3 mm. Our two-point phantom outperformed a commercial one in terms of peak difference (6% versus 72%) and peak-to-valley ratio (75.3 versus 14.1). The fish-like phantom shows that printing hot regions and air cavities onto a uniform background is feasible. Future steps include using longer-lived radionuclides like 89Zr and 22Na.","PeriodicalId":46807,"journal":{"name":"IEEE Transactions on Radiation and Plasma Medical Sciences","volume":"9 3","pages":"362-371"},"PeriodicalIF":4.6000,"publicationDate":"2024-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10742298","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Radiation and Plasma Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10742298/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

This study explores the potential of digital light processing to 3-D print radioactive phantoms for high-resolution positron emission tomography (PET). Using a slightly modified desktop 3-D printer and mixtures of 18F-FDG (T1/2: 109.8 min) and photopolymer resin, we have printed standardized and custom radioactive objects designed for ultrahigh-resolution PET, also as a first step toward complex geometries. The phantoms were: a flood source to assess uniformity, a two-point phantom for spatial resolution assessment, a multiline phantom for validating submillimeter printing resolution, a fish-like phantom with different activity concentrations, and a 50%-downscaled micro-PET image quality phantom (National Electrical Manufacturers Association NU 4-2008). Positron range effects were examined on the latter using a removable cover. The evaluation relied on planar images from a phosphor imager and tomographic images from a commercial small animal PET scanner. We were able to print radioactive uniform distributions with relative standard deviation below 4.5% and structures as small as 0.3 mm. Our two-point phantom outperformed a commercial one in terms of peak difference (6% versus 72%) and peak-to-valley ratio (75.3 versus 14.1). The fish-like phantom shows that printing hot regions and air cavities onto a uniform background is feasible. Future steps include using longer-lived radionuclides like 89Zr and 22Na.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
IEEE Transactions on Radiation and Plasma Medical Sciences
IEEE Transactions on Radiation and Plasma Medical Sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
8.00
自引率
18.20%
发文量
109
期刊最新文献
Table of Contents Affiliate Plan of the IEEE Nuclear and Plasma Sciences Society IEEE Transactions on Radiation and Plasma Medical Sciences Information for Authors IEEE Transactions on Radiation and Plasma Medical Sciences Publication Information Affiliate Plan of the IEEE Nuclear and Plasma Sciences Society
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1