{"title":"Dedicated 3D-Printed Radioactive Phantoms With ¹⁸F-FDG for Ultrahigh-Resolution PET","authors":"Ezzat Elmoujarkach;Steven Seeger;Luise Morgner;Fabian Schmidt;Julia G. Mannheim;Christian L. Schmidt;Magdalena Rafecas","doi":"10.1109/TRPMS.2024.3483233","DOIUrl":null,"url":null,"abstract":"This study explores the potential of digital light processing to 3-D print radioactive phantoms for high-resolution positron emission tomography (PET). Using a slightly modified desktop 3-D printer and mixtures of 18F-FDG (T1/2: 109.8 min) and photopolymer resin, we have printed standardized and custom radioactive objects designed for ultrahigh-resolution PET, also as a first step toward complex geometries. The phantoms were: a flood source to assess uniformity, a two-point phantom for spatial resolution assessment, a multiline phantom for validating submillimeter printing resolution, a fish-like phantom with different activity concentrations, and a 50%-downscaled micro-PET image quality phantom (National Electrical Manufacturers Association NU 4-2008). Positron range effects were examined on the latter using a removable cover. The evaluation relied on planar images from a phosphor imager and tomographic images from a commercial small animal PET scanner. We were able to print radioactive uniform distributions with relative standard deviation below 4.5% and structures as small as 0.3 mm. Our two-point phantom outperformed a commercial one in terms of peak difference (6% versus 72%) and peak-to-valley ratio (75.3 versus 14.1). The fish-like phantom shows that printing hot regions and air cavities onto a uniform background is feasible. Future steps include using longer-lived radionuclides like 89Zr and 22Na.","PeriodicalId":46807,"journal":{"name":"IEEE Transactions on Radiation and Plasma Medical Sciences","volume":"9 3","pages":"362-371"},"PeriodicalIF":3.5000,"publicationDate":"2024-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10742298","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Radiation and Plasma Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10742298/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

This study explores the potential of digital light processing to 3-D print radioactive phantoms for high-resolution positron emission tomography (PET). Using a slightly modified desktop 3-D printer and mixtures of 18F-FDG (T1/2: 109.8 min) and photopolymer resin, we have printed standardized and custom radioactive objects designed for ultrahigh-resolution PET, also as a first step toward complex geometries. The phantoms were: a flood source to assess uniformity, a two-point phantom for spatial resolution assessment, a multiline phantom for validating submillimeter printing resolution, a fish-like phantom with different activity concentrations, and a 50%-downscaled micro-PET image quality phantom (National Electrical Manufacturers Association NU 4-2008). Positron range effects were examined on the latter using a removable cover. The evaluation relied on planar images from a phosphor imager and tomographic images from a commercial small animal PET scanner. We were able to print radioactive uniform distributions with relative standard deviation below 4.5% and structures as small as 0.3 mm. Our two-point phantom outperformed a commercial one in terms of peak difference (6% versus 72%) and peak-to-valley ratio (75.3 versus 14.1). The fish-like phantom shows that printing hot regions and air cavities onto a uniform background is feasible. Future steps include using longer-lived radionuclides like 89Zr and 22Na.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
¹⁸F-FDG专用于超高分辨率PET的3d打印放射性幻影
本研究探索了数字光处理在高分辨率正电子发射断层扫描(PET)的3d打印放射性幻影中的潜力。使用稍微改进的台式3d打印机和18F-FDG (T1/2: 109.8分钟)和光聚合物树脂的混合物,我们已经打印出了为超高分辨率PET设计的标准化和定制放射性物体,这也是迈向复杂几何形状的第一步。这些幻影是:用于评估均匀性的洪水源,用于空间分辨率评估的两点幻影,用于验证亚毫米打印分辨率的多线幻影,具有不同活动浓度的鱼状幻影,以及缩小50%的微型pet图像质量幻影(国家电气制造商协会NU 4-2008)。正电子范围效应是用一个可移动的盖子来检测的。评估依赖于来自荧光粉成像仪的平面图像和来自商用小动物PET扫描仪的层析图像。我们能够打印出相对标准偏差小于4.5%的放射性均匀分布和小至0.3 mm的结构。我们的两点幻影在峰值差(6%比72%)和峰谷比(75.3比14.1)方面优于商用幻影。鱼状的幻影表明,将热区和空腔打印到统一的背景上是可行的。未来的步骤包括使用寿命更长的放射性核素,如89Zr和22Na。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
IEEE Transactions on Radiation and Plasma Medical Sciences
IEEE Transactions on Radiation and Plasma Medical Sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
8.00
自引率
18.20%
发文量
109
期刊最新文献
Affiliate Plan of the IEEE Nuclear and Plasma Sciences Society Table of Contents IEEE DataPort IEEE Transactions on Radiation and Plasma Medical Sciences Information for Authors IEEE Transactions on Radiation and Plasma Medical Sciences Publication Information
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1