Gamma-Ray Position-of-Interaction Estimation in a Thick Monolithic LaBr3 Detector Using Artificial Neural Networks

IF 4.6 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING IEEE Transactions on Radiation and Plasma Medical Sciences Pub Date : 2024-11-06 DOI:10.1109/TRPMS.2024.3492674
T. Ferri;F. Rosellini;A. Caracciolo;G. Borghi;M. Carminati;F. Camera;A. Giaz;C. Fiorini
{"title":"Gamma-Ray Position-of-Interaction Estimation in a Thick Monolithic LaBr3 Detector Using Artificial Neural Networks","authors":"T. Ferri;F. Rosellini;A. Caracciolo;G. Borghi;M. Carminati;F. Camera;A. Giaz;C. Fiorini","doi":"10.1109/TRPMS.2024.3492674","DOIUrl":null,"url":null,"abstract":"Monolithic gamma-ray detectors can be used in single photon emission computed tomography systems for monitoring the delivered dose during boron neutron capture therapy treatments. Gamma-ray hit localization in thick monolithic scintillator crystals is a challenging task due to internal reflections and Compton scattering. Existing methods like the center of gravity (CoG) are susceptible to reconstruction uncertainties at the crystal edges, while approaches, including nonlinear analytical and statistical models, such as the maximum-likelihood, require significant computational resources. Artificial neural networks (ANNs) offer significant improvements in terms of accuracy and computational speed. In this study, we develop a supervised ANN regression algorithm for real-time position reconstruction in a thick square lanthanum bromide crystal [LaBr<inline-formula> <tex-math>$_{3}(\\text {Ce}+\\text {Sr})$ </tex-math></inline-formula>] with <inline-formula> <tex-math>$5\\, \\text {cm}\\times 5\\,\\text {cm}\\times 2\\,\\text {cm}$ </tex-math></inline-formula> dimensions, coupled with an <inline-formula> <tex-math>$8\\times 8$ </tex-math></inline-formula> matrix of silicon photomultipliers. The implemented neural network was trained and tested using calibration data acquired irradiating the crystal with a collimated 137Cs source (pencil-beam irradiation). The detector in combination with the ANN model achieves a positioning accuracy for single-gamma-ray events of approximately 2.6 mm in the central region, evaluated as the full width at half maximum (FWHM) of the prediction error distribution, slightly worsening toward the edges. The imaging capabilities of the detector in combination with a channel-edge pinhole collimator were then evaluated by acquiring images of a movable uncollimated 137Cs point source. The source was shifted in nine different positions at 3 mm distance from each other and the resolution of the system was evaluated fitting the images with a Gaussian curve. An image spatial resolution of around 8 mm FWHM was obtained, dominated as expected by the collimator geometry, with an accuracy of 0.7 mm in estimating the position of the point source.","PeriodicalId":46807,"journal":{"name":"IEEE Transactions on Radiation and Plasma Medical Sciences","volume":"9 3","pages":"284-295"},"PeriodicalIF":4.6000,"publicationDate":"2024-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10745622","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Radiation and Plasma Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10745622/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Monolithic gamma-ray detectors can be used in single photon emission computed tomography systems for monitoring the delivered dose during boron neutron capture therapy treatments. Gamma-ray hit localization in thick monolithic scintillator crystals is a challenging task due to internal reflections and Compton scattering. Existing methods like the center of gravity (CoG) are susceptible to reconstruction uncertainties at the crystal edges, while approaches, including nonlinear analytical and statistical models, such as the maximum-likelihood, require significant computational resources. Artificial neural networks (ANNs) offer significant improvements in terms of accuracy and computational speed. In this study, we develop a supervised ANN regression algorithm for real-time position reconstruction in a thick square lanthanum bromide crystal [LaBr $_{3}(\text {Ce}+\text {Sr})$ ] with $5\, \text {cm}\times 5\,\text {cm}\times 2\,\text {cm}$ dimensions, coupled with an $8\times 8$ matrix of silicon photomultipliers. The implemented neural network was trained and tested using calibration data acquired irradiating the crystal with a collimated 137Cs source (pencil-beam irradiation). The detector in combination with the ANN model achieves a positioning accuracy for single-gamma-ray events of approximately 2.6 mm in the central region, evaluated as the full width at half maximum (FWHM) of the prediction error distribution, slightly worsening toward the edges. The imaging capabilities of the detector in combination with a channel-edge pinhole collimator were then evaluated by acquiring images of a movable uncollimated 137Cs point source. The source was shifted in nine different positions at 3 mm distance from each other and the resolution of the system was evaluated fitting the images with a Gaussian curve. An image spatial resolution of around 8 mm FWHM was obtained, dominated as expected by the collimator geometry, with an accuracy of 0.7 mm in estimating the position of the point source.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
IEEE Transactions on Radiation and Plasma Medical Sciences
IEEE Transactions on Radiation and Plasma Medical Sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
8.00
自引率
18.20%
发文量
109
期刊最新文献
Table of Contents Affiliate Plan of the IEEE Nuclear and Plasma Sciences Society IEEE Transactions on Radiation and Plasma Medical Sciences Information for Authors IEEE Transactions on Radiation and Plasma Medical Sciences Publication Information Affiliate Plan of the IEEE Nuclear and Plasma Sciences Society
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1