Enhanced Row–Column-Addressed Array Imaging With Retrospective Filtering

Chung-Shiang Mei;Wei-Hsiang Shen;Meng-Lin Li
{"title":"Enhanced Row–Column-Addressed Array Imaging With Retrospective Filtering","authors":"Chung-Shiang Mei;Wei-Hsiang Shen;Meng-Lin Li","doi":"10.1109/OJUFFC.2025.3545600","DOIUrl":null,"url":null,"abstract":"To address the inherent complexity associated with fabricating fully-sampled (FS) 2-D arrays, row-column-addressed (RCA) arrays offer a promising alternative by significantly reducing the number of active elements. However, RCA arrays are limited by reduced image quality, as they only allow one-way focusing along both the x- and y-axes. This study introduces a post-filtering scheme that leverages a retrospective filtering method combined with filter-derived coherence-index (FCI) weighting to enhance RCA focusing quality, aiming to emulate the performance of FS arrays. Preliminary simulations were conducted to assess the efficacy of this approach, including point spread function (PSF) analysis and anechoic vessel phantom imaging. In the PSF analysis, our method achieved a 14.63-dB reduction in the sidelobe level, with improvements of 11.3% and 14.29% observed in the -6 dB and -20 dB full-width at half-maximum (FWHM), respectively. For anechoic vessel phantom imaging, the proposed scheme demonstrated substantial gains, with a 15.77 dB enhancement in contrast ratio (CR), a 1.615 increase in contrast-to-noise ratio (CNR), and a 27.03% improvement in generalized contrast-to-noise ratio (gCNR).","PeriodicalId":73301,"journal":{"name":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","volume":"5 ","pages":"15-18"},"PeriodicalIF":2.9000,"publicationDate":"2025-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10902463","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10902463/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

To address the inherent complexity associated with fabricating fully-sampled (FS) 2-D arrays, row-column-addressed (RCA) arrays offer a promising alternative by significantly reducing the number of active elements. However, RCA arrays are limited by reduced image quality, as they only allow one-way focusing along both the x- and y-axes. This study introduces a post-filtering scheme that leverages a retrospective filtering method combined with filter-derived coherence-index (FCI) weighting to enhance RCA focusing quality, aiming to emulate the performance of FS arrays. Preliminary simulations were conducted to assess the efficacy of this approach, including point spread function (PSF) analysis and anechoic vessel phantom imaging. In the PSF analysis, our method achieved a 14.63-dB reduction in the sidelobe level, with improvements of 11.3% and 14.29% observed in the -6 dB and -20 dB full-width at half-maximum (FWHM), respectively. For anechoic vessel phantom imaging, the proposed scheme demonstrated substantial gains, with a 15.77 dB enhancement in contrast ratio (CR), a 1.615 increase in contrast-to-noise ratio (CNR), and a 27.03% improvement in generalized contrast-to-noise ratio (gCNR).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
增强行-列寻址阵列成像回顾性滤波
为了解决与制造全采样(FS)二维阵列相关的固有复杂性,行-列寻址(RCA)阵列通过显着减少有源元件的数量提供了一个有前途的替代方案。然而,RCA阵列受到图像质量降低的限制,因为它们只允许沿x轴和y轴单向聚焦。本研究引入了一种后滤波方案,该方案利用回溯滤波方法结合滤波器衍生相干指数(FCI)加权来提高RCA聚焦质量,旨在模拟FS阵列的性能。进行了初步模拟以评估该方法的有效性,包括点扩散函数(PSF)分析和消声血管影成像。在PSF分析中,我们的方法使旁瓣电平降低了14.63 dB,在半最大值(FWHM)的-6 dB和-20 dB全宽分别提高了11.3%和14.29%。对于无回声血管影成像,该方案显示出显著的增益,对比度(CR)提高15.77 dB,对比噪声比(CNR)提高1.615,广义对比噪声比(gCNR)提高27.03%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Impact of Training Data Composition on Deep Learning-Based Cardiac Motion Estimation The Added Value of Cascaded Plane Wave Imaging for Autocorrelation- and Cross-Correlation-Based Velocity Vector Imaging Simultaneous Estimation of Blood Pressure and Volume Flow Using Deep Learning- Enhanced Ultrafast Ultrasound Miniaturized Ultrasonic Transducer With PMN-PT Embedded Into Flexible LCP Substrate for Biocompatible Applications Active Inference for Closed-Loop Transmit Beamsteering in Fetal Doppler Ultrasound
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1