Evaluation of an Automated Fluorescence Enzyme Immunoassay for Quantification of Equine Insulin and Comparison to Five Other Immunoassays

IF 2.1 2区 农林科学 Q1 VETERINARY SCIENCES Journal of Veterinary Internal Medicine Pub Date : 2025-03-06 DOI:10.1111/jvim.70038
Rose D. Nolen-Walston, Jeaneen C. Kulp, Darko Stefanovski, Andrew W. van Eps
{"title":"Evaluation of an Automated Fluorescence Enzyme Immunoassay for Quantification of Equine Insulin and Comparison to Five Other Immunoassays","authors":"Rose D. Nolen-Walston,&nbsp;Jeaneen C. Kulp,&nbsp;Darko Stefanovski,&nbsp;Andrew W. van Eps","doi":"10.1111/jvim.70038","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Hyperinsulinemia is an important and treatable risk factor for laminitis in horses.</p>\n </section>\n \n <section>\n \n <h3> Objectives</h3>\n \n <p>Evaluate the Tosoh AIA-360 automated fluorescence enzyme immunoassay for the measurement of serum insulin concentrations in horses, and compare it to five other immunoassays for insulin quantification.</p>\n </section>\n \n <section>\n \n <h3> Animals</h3>\n \n <p>One hundred serum samples from 83 horses were submitted for insulin measurement.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>The Tosoh AIA-360 was assessed against a reference assay (radioactive immunoassay; RIA). Using the same samples, TOS-FEIA, ELISA, and three chemiluminescent immunoassays (CLIA) were assessed for correlation and agreement with RIA.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The TOS-FEIA showed excellent correlation with RIA (<i>r</i><sup>2</sup> = 0.94, <i>p</i> &lt; 0.0001) and good agreement, with a Bland–Altman constant bias (limits of agreement) of −23.8 μIU/mL (−74.6 to 27.0) and Passing–Bablok fit of <i>y</i> = −8.9 + 0.78<i>x</i>. Mean coefficients of variation were 1.8% for intra-assay and 5.7% for inter-assay precision, with mean recovery upon dilution of 104.2%. The assay comparison yielded good or excellent agreement (constant bias, limits of agreement) with RIA in the &lt; 100 μIU/mL cohort for the ELISA (−7.0, −21.4 to 7.4) and the Cobas e CLIA (−31.4, −60.9 to −1.6). Spuriously high results (2 to &gt; 10-fold of RIA result) were obtained in approximately 10% of results from both Immulite 2000 and 2000XPi CLIA analyzers, rendering the agreement poor.</p>\n </section>\n \n <section>\n \n <h3> Conclusions and Clinical Importance</h3>\n \n <p>The TOS-FEIA had acceptable accuracy and precision for clinical use, including at concentrations of insulin &lt; 100 μIU/mL. The ELISA and one CLIA (Cobas e) showed acceptable accuracy, but the Cobas e demonstrated marked bias compared with RIA. Both Immulite CLIA assays exhibited unacceptable accuracy.</p>\n </section>\n </div>","PeriodicalId":49958,"journal":{"name":"Journal of Veterinary Internal Medicine","volume":"39 2","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2025-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/jvim.70038","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Veterinary Internal Medicine","FirstCategoryId":"97","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jvim.70038","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Hyperinsulinemia is an important and treatable risk factor for laminitis in horses.

Objectives

Evaluate the Tosoh AIA-360 automated fluorescence enzyme immunoassay for the measurement of serum insulin concentrations in horses, and compare it to five other immunoassays for insulin quantification.

Animals

One hundred serum samples from 83 horses were submitted for insulin measurement.

Methods

The Tosoh AIA-360 was assessed against a reference assay (radioactive immunoassay; RIA). Using the same samples, TOS-FEIA, ELISA, and three chemiluminescent immunoassays (CLIA) were assessed for correlation and agreement with RIA.

Results

The TOS-FEIA showed excellent correlation with RIA (r2 = 0.94, p < 0.0001) and good agreement, with a Bland–Altman constant bias (limits of agreement) of −23.8 μIU/mL (−74.6 to 27.0) and Passing–Bablok fit of y = −8.9 + 0.78x. Mean coefficients of variation were 1.8% for intra-assay and 5.7% for inter-assay precision, with mean recovery upon dilution of 104.2%. The assay comparison yielded good or excellent agreement (constant bias, limits of agreement) with RIA in the < 100 μIU/mL cohort for the ELISA (−7.0, −21.4 to 7.4) and the Cobas e CLIA (−31.4, −60.9 to −1.6). Spuriously high results (2 to > 10-fold of RIA result) were obtained in approximately 10% of results from both Immulite 2000 and 2000XPi CLIA analyzers, rendering the agreement poor.

Conclusions and Clinical Importance

The TOS-FEIA had acceptable accuracy and precision for clinical use, including at concentrations of insulin < 100 μIU/mL. The ELISA and one CLIA (Cobas e) showed acceptable accuracy, but the Cobas e demonstrated marked bias compared with RIA. Both Immulite CLIA assays exhibited unacceptable accuracy.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.50
自引率
11.50%
发文量
243
审稿时长
22 weeks
期刊介绍: The mission of the Journal of Veterinary Internal Medicine is to advance veterinary medical knowledge and improve the lives of animals by publication of authoritative scientific articles of animal diseases.
期刊最新文献
Corticosteroid Administration Enhances the Glycemic, Insulinemic, and Incretin Responses to a High-Protein Mixed Meal in Adult Horses Blood Carboxyhemoglobin Concentrations as a Diagnostic Biomarker of Hemolytic Anemias in Cats Daily Heart Rate Variability in Dogs With Atrial Fibrillation Factors Affecting the Quality of Histopathologic Specimens Obtained via Small Intestinal Endoscopic Biopsy in Dogs and Cats Risk Factors and Long-Term Outcomes in Horses After the 2021 Outbreak of Equine Herpesvirus 1 Myeloencephalopathy, Valencia, Spain
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1