Natalia Gonzaga, Lycio Shinji Watanabe, Samanta Stinghen de Abreu, Stael Málaga Carrilho, Fernanda Montanholi de Lira, Ronaldo Tamanini, Suzana Lucy Nixdorf, Vanerli Beloti
{"title":"Development and validation of a novel HPLC-PDA method for the detection of preservatives in milk.","authors":"Natalia Gonzaga, Lycio Shinji Watanabe, Samanta Stinghen de Abreu, Stael Málaga Carrilho, Fernanda Montanholi de Lira, Ronaldo Tamanini, Suzana Lucy Nixdorf, Vanerli Beloti","doi":"10.1017/S0022029925000044","DOIUrl":null,"url":null,"abstract":"<p><p>In this research paper we introduce and validate an enhanced method for the detection of sodium benzoate and potassium sorbate in milk. Sodium benzoate and potassium sorbate are widely employed as preservatives in the food industry; however, their use to restrict microbial growth in milk is prohibited. Our novel method achieved performance indicators in accordance with the criteria outlined by the International Conference on Harmonization. The extraction process involved sample dilution in acetonitrile (1:1 v/v), followed by subsequent centrifugation, filtration and injection into a high-performance liquid chromatography system with a photodiode array detector. The detection and quantification limits for sodium benzoate were determined to be 0.204 and 0.618 mg/l, respectively, while for potassium sorbate, these values were 0.108 and 0.328 mg/l, respectively. The accuracy ranged from 92.67 to 99.53%, with pH 4.0 selected as the optimal condition to ensure adequate resolution of the preservatives. The proposed method stands out due to its simplicity and speed, using a single reagent in modest quantities during sample preparation. This approach reduces toxicity and minimizes the production of pollutants during disposal. Furthermore, the novel method requires less raw material and energy consumption, aligning with the principles of green chemistry. Its lower quantitation limits render it more sensitive when compared to the official analysis. The preparation, separation, and simultaneous detection of these preservatives in a short period of time make this method suitable for integration into industrial workflows.</p>","PeriodicalId":15615,"journal":{"name":"Journal of Dairy Research","volume":" ","pages":"1-6"},"PeriodicalIF":1.6000,"publicationDate":"2025-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dairy Research","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1017/S0022029925000044","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"AGRICULTURE, DAIRY & ANIMAL SCIENCE","Score":null,"Total":0}
引用次数: 0
Abstract
In this research paper we introduce and validate an enhanced method for the detection of sodium benzoate and potassium sorbate in milk. Sodium benzoate and potassium sorbate are widely employed as preservatives in the food industry; however, their use to restrict microbial growth in milk is prohibited. Our novel method achieved performance indicators in accordance with the criteria outlined by the International Conference on Harmonization. The extraction process involved sample dilution in acetonitrile (1:1 v/v), followed by subsequent centrifugation, filtration and injection into a high-performance liquid chromatography system with a photodiode array detector. The detection and quantification limits for sodium benzoate were determined to be 0.204 and 0.618 mg/l, respectively, while for potassium sorbate, these values were 0.108 and 0.328 mg/l, respectively. The accuracy ranged from 92.67 to 99.53%, with pH 4.0 selected as the optimal condition to ensure adequate resolution of the preservatives. The proposed method stands out due to its simplicity and speed, using a single reagent in modest quantities during sample preparation. This approach reduces toxicity and minimizes the production of pollutants during disposal. Furthermore, the novel method requires less raw material and energy consumption, aligning with the principles of green chemistry. Its lower quantitation limits render it more sensitive when compared to the official analysis. The preparation, separation, and simultaneous detection of these preservatives in a short period of time make this method suitable for integration into industrial workflows.
期刊介绍:
The Journal of Dairy Research is an international Journal of high-standing that publishes original scientific research on all aspects of the biology, wellbeing and technology of lactating animals and the foods they produce. The Journal’s ability to cover the entire dairy foods chain is a major strength. Cross-disciplinary research is particularly welcomed, as is comparative lactation research in different dairy and non-dairy species and research dealing with consumer health aspects of dairy products. Journal of Dairy Research: an international Journal of the lactation sciences.