Detectability of acute ischemic stroke with thin (3 mm) axial versus thin (3 mm) coronal diffusion-weighted imaging in patients presenting to the emergency department with acute dizziness.

IF 1.7 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Emergency Radiology Pub Date : 2025-03-07 DOI:10.1007/s10140-025-02327-4
Richard J Lozano, Faryal Shareef, Anish Neupane, Zaid Siddique, Rudra Joshi, Luca Pasquini, Long H Tu, Amit Mahajan
{"title":"Detectability of acute ischemic stroke with thin (3 mm) axial versus thin (3 mm) coronal diffusion-weighted imaging in patients presenting to the emergency department with acute dizziness.","authors":"Richard J Lozano, Faryal Shareef, Anish Neupane, Zaid Siddique, Rudra Joshi, Luca Pasquini, Long H Tu, Amit Mahajan","doi":"10.1007/s10140-025-02327-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and purpose: </strong>Ischemic strokes can cause vertigo, particularly when involving the posterior circulation of the brain. Prior research has suggested that thin-Sect. (3 mm) axial or coronal DWI may improve the detection of ischemic stroke compared to thick (5 mm) DWI. However, relative sensitivity of differing thin DWI sequences is unknown. In this retrospective cohort study, we compare the sensitivity of thin coronal DWI and thin axial DWI in detection of brain ischemia.</p><p><strong>Materials and methods: </strong>Retrospective study at a single institution (2/18/2020-8/31/2023) of patients who presented to the emergency department with vertigo/dizziness and underwent an abbreviated MRI protocol (3 mm axial DWI, 3 mm coronal DWI, axial FLAIR, and axial SWI). For each case with an ischemic lesion, the visibility of infarct on thin axial and coronal DWIs was rated; location and size were also recorded. Visibility on either sequence was considered the reference standard. Sensitivity was compared with McNemar's test.</p><p><strong>Results: </strong>615 abbreviated MRI examinations were performed; 24/615 (3.9%) had an ischemic lesion (15 cerebral, 7 brainstem, 13 cerebellar). 24 of these MRI examinations with ischemic lesions were performed using 3 mm axial MRI and on 3T MRI. All lesions (24/24) were visible on thin axial DWI (100% sensitivity, 95% CI: 0.95-1.00). Fewer lesions (20/24) were seen on thin coronal DWI (83% sensitivity, 95% CI: 0.72-0.91). The difference in sensitivity was statistically significant (p = 0.0374). Lesions not visible on coronal DWI were 2-8 mm in size, the largest in the middle cerebellar peduncle.</p><p><strong>Conclusions: </strong>Thin coronal DWI may not improve additional diagnostic utility beyond thin axial DWI for the detection of ischemia in patients with dizziness. When designing protocols tailored for stroke detection (particularly in the posterior circulation), replacing conventional (5 mm) DWI with thin (3 mm) axial DWI may be preferable to adding a thin coronal sequence.</p>","PeriodicalId":11623,"journal":{"name":"Emergency Radiology","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2025-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Emergency Radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10140-025-02327-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background and purpose: Ischemic strokes can cause vertigo, particularly when involving the posterior circulation of the brain. Prior research has suggested that thin-Sect. (3 mm) axial or coronal DWI may improve the detection of ischemic stroke compared to thick (5 mm) DWI. However, relative sensitivity of differing thin DWI sequences is unknown. In this retrospective cohort study, we compare the sensitivity of thin coronal DWI and thin axial DWI in detection of brain ischemia.

Materials and methods: Retrospective study at a single institution (2/18/2020-8/31/2023) of patients who presented to the emergency department with vertigo/dizziness and underwent an abbreviated MRI protocol (3 mm axial DWI, 3 mm coronal DWI, axial FLAIR, and axial SWI). For each case with an ischemic lesion, the visibility of infarct on thin axial and coronal DWIs was rated; location and size were also recorded. Visibility on either sequence was considered the reference standard. Sensitivity was compared with McNemar's test.

Results: 615 abbreviated MRI examinations were performed; 24/615 (3.9%) had an ischemic lesion (15 cerebral, 7 brainstem, 13 cerebellar). 24 of these MRI examinations with ischemic lesions were performed using 3 mm axial MRI and on 3T MRI. All lesions (24/24) were visible on thin axial DWI (100% sensitivity, 95% CI: 0.95-1.00). Fewer lesions (20/24) were seen on thin coronal DWI (83% sensitivity, 95% CI: 0.72-0.91). The difference in sensitivity was statistically significant (p = 0.0374). Lesions not visible on coronal DWI were 2-8 mm in size, the largest in the middle cerebellar peduncle.

Conclusions: Thin coronal DWI may not improve additional diagnostic utility beyond thin axial DWI for the detection of ischemia in patients with dizziness. When designing protocols tailored for stroke detection (particularly in the posterior circulation), replacing conventional (5 mm) DWI with thin (3 mm) axial DWI may be preferable to adding a thin coronal sequence.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Emergency Radiology
Emergency Radiology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.60
自引率
4.50%
发文量
98
期刊介绍: To advance and improve the radiologic aspects of emergency careTo establish Emergency Radiology as an area of special interest in the field of diagnostic imagingTo improve methods of education in Emergency RadiologyTo provide, through formal meetings, a mechanism for presentation of scientific papers on various aspects of Emergency Radiology and continuing educationTo promote research in Emergency Radiology by clinical and basic science investigators, including residents and other traineesTo act as the resource body on Emergency Radiology for those interested in emergency patient care Members of the American Society of Emergency Radiology (ASER) receive the Emergency Radiology journal as a benefit of membership!
期刊最新文献
Computed tomography imaging findings in head injury victims of conflict in Northern Ethiopia treated at the University of Gondar comprehensive specialized hospital. Detectability of acute ischemic stroke with thin (3 mm) axial versus thin (3 mm) coronal diffusion-weighted imaging in patients presenting to the emergency department with acute dizziness. Transient enhancement of chronic subdural hematomas: a clinical report of a mimic of acute intracranial hemorrhage. Computed tomographic pulmonary angiography using low tube voltage and slow contrast medium injection. Impact of a multi-modal intervention on CTA ordering rates in patients presenting with vertigo to the emergency department.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1