{"title":"Comparing Ultrasound, Chest X-Ray, and CT Scan for Pneumonia Detection.","authors":"Ziyad F Al Nufaiei, Khalid M Alshamrani","doi":"10.2147/MDER.S501714","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The clinical methods of diagnosing pneumonia have been for many years chest X-rays (CXR) and computed tomography (CT) scans. However, a relatively new modality that is promising, efficient, and cheap is the lung ultrasound (LUS). The scope of this systematic review focuses on evaluating the diagnostic performance of LUS, CXR, and CT for diagnosing pneumonia.</p><p><strong>Objective: </strong>The first aim of this review is to assess the diagnostic accuracy of lung ultrasound in comparison with chest X-rays and CT scans.</p><p><strong>Methods: </strong>PubMed, Cochrane, Embase, and Scopus were electronically searched without date and language limitations were set. Inclusion criteria covered only those diagnostic studies that involved comparing lung ultrasound, chest X-ray, and CT scans in human beings with suspected pneumonia. Both abstraction and quality of studies were assessed by two researchers and the quality was assessed using PRISMA and QUADAS-2 checklists.</p><p><strong>Results: </strong>There were 13 empirical studies included in the review which referred to different patients and contexts. Although none of the imaging techniques could achieve both high sensitivity and high specificity, CT scans produced the highest sensitivity, with values higher than 95% on all occasions, and specificities ranging between 80% and 90%. Lung US was most helpful in pediatric and acute care populations, whereas CT was preferred when there was uncertainty regarding the presentation.</p><p><strong>Conclusion: </strong>Lung ultrasound is a very sensitive, specific, practical method of subsequent lung examination; it is useful in environments that need fast bedside assessment and for patients particularly vulnerable to radiation exposure, such as children. Even though chest X-ray remains valuable in excluding pneumonia in outpatient practices, it lacks sensitivity and is therefore less useful in diagnosing early disease. Computed tomography scans are the most accurate type of scans but should only be used in the more severe interventions due to cost and radiation exposure.</p>","PeriodicalId":47140,"journal":{"name":"Medical Devices-Evidence and Research","volume":"18 ","pages":"149-159"},"PeriodicalIF":1.3000,"publicationDate":"2025-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11889995/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Devices-Evidence and Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/MDER.S501714","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The clinical methods of diagnosing pneumonia have been for many years chest X-rays (CXR) and computed tomography (CT) scans. However, a relatively new modality that is promising, efficient, and cheap is the lung ultrasound (LUS). The scope of this systematic review focuses on evaluating the diagnostic performance of LUS, CXR, and CT for diagnosing pneumonia.

Objective: The first aim of this review is to assess the diagnostic accuracy of lung ultrasound in comparison with chest X-rays and CT scans.

Methods: PubMed, Cochrane, Embase, and Scopus were electronically searched without date and language limitations were set. Inclusion criteria covered only those diagnostic studies that involved comparing lung ultrasound, chest X-ray, and CT scans in human beings with suspected pneumonia. Both abstraction and quality of studies were assessed by two researchers and the quality was assessed using PRISMA and QUADAS-2 checklists.

Results: There were 13 empirical studies included in the review which referred to different patients and contexts. Although none of the imaging techniques could achieve both high sensitivity and high specificity, CT scans produced the highest sensitivity, with values higher than 95% on all occasions, and specificities ranging between 80% and 90%. Lung US was most helpful in pediatric and acute care populations, whereas CT was preferred when there was uncertainty regarding the presentation.

Conclusion: Lung ultrasound is a very sensitive, specific, practical method of subsequent lung examination; it is useful in environments that need fast bedside assessment and for patients particularly vulnerable to radiation exposure, such as children. Even though chest X-ray remains valuable in excluding pneumonia in outpatient practices, it lacks sensitivity and is therefore less useful in diagnosing early disease. Computed tomography scans are the most accurate type of scans but should only be used in the more severe interventions due to cost and radiation exposure.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
比较超声波、胸部 X 光和 CT 扫描在肺炎检测中的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Medical Devices-Evidence and Research
Medical Devices-Evidence and Research ENGINEERING, BIOMEDICAL-
CiteScore
2.80
自引率
0.00%
发文量
41
审稿时长
16 weeks
期刊最新文献
Clinical Outcomes Among Patients Undergoing Open Abdominal or Orthopedic Surgery with Wound Closure Incorporating Triclosan-Coated Barbed Sutures: A Multi-Institutional, Retrospective Database Study. Comparing Ultrasound, Chest X-Ray, and CT Scan for Pneumonia Detection. Engineering a Quality Management System for Academic Research: Navigating Challenges to Comply with the New Medical Device Regulations in Europe. Non-Invasive Laser Surgery With Deep Operating Depth Using Multibeam Interference. Feasibility and Usability of Low-Field Magnetic Resonance Imaging for Pediatric Neuroimaging in Low- and Middle-Income Countries: A Qualitative Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1