Impact of the Physiological Parameters of the Oral Cavity on the Mechanical Properties of Zinc-stabilized and Zinc-free Adhesive Creams: A Comparative In Vitro Study.

Josephine Reymann, Anantha Narayanan Ramakrishnan, Christopher Ludtka, Jeremias Hey, Andreas Kiesow, Stefan Schwan
{"title":"Impact of the Physiological Parameters of the Oral Cavity on the Mechanical Properties of Zinc-stabilized and Zinc-free Adhesive Creams: A Comparative In Vitro Study.","authors":"Josephine Reymann, Anantha Narayanan Ramakrishnan, Christopher Ludtka, Jeremias Hey, Andreas Kiesow, Stefan Schwan","doi":"10.3290/j.jad.c_1871","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The current trend in denture adhesives is shifting toward zinc-free formulations due to the significant health concerns associated with zinc. Studies have focused on the retention of these zinc-free denture adhesives; however, there is a dearth of literature regarding their damping performance. This study analyzes the impact of oral cavity physiological parameters: temperature, pH, and swelling ratio on the mechanical properties of zinc-stabilized and zinc-free denture adhesives and examines the role zinc plays in influencing the adhesive behavior. This study investigates how underlying mechanical properties of adhesive cream change for zinc-stabilized and zinc-free denture adhesives. The relative damping and its variation from exposure to physiological conditions in the oral cavity can significantly assist in the design of dentures to reduce the discomfort experienced by denture wearers.</p><p><strong>Materials and methods: </strong>The relative damping of the zinc-stabilized and zinc-free denture adhesives was investigated with the loss modulus values, which were evaluated using rheological frequency sweep tests. The tests were performed by maintaining the denture adhesives at specified values of temperature, pH, and swelling ratio, and over a frequency range of 0.01 Hz to 10 Hz, which included the average frequencies of human chewing / bite forces reported in existing literature.</p><p><strong>Results: </strong>Zinc-stabilized denture adhesive showed a larger fluctuation of loss modulus values compared to the zinc-free formulation with respect to pH, temperature, and swelling ratios. The zinc-free denture adhesive showed higher damping behavior at frequencies below 0.7 Hz, whereas the zinc-stabilized denture adhesive showed higher damping behavior above loading frequencies of 0.7-1 Hz. Both the adhesives showed varying behavior on either side of the bite force spectrum in terms of relative damping of the applied bite.</p><p><strong>Conclusions: </strong>The damping or cushioning effect provided by denture adhesives can reduce pain experienced and assist dental practitioners in better supporting denture wearers.</p>","PeriodicalId":94234,"journal":{"name":"The journal of adhesive dentistry","volume":"27 ","pages":"21-29"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The journal of adhesive dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3290/j.jad.c_1871","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The current trend in denture adhesives is shifting toward zinc-free formulations due to the significant health concerns associated with zinc. Studies have focused on the retention of these zinc-free denture adhesives; however, there is a dearth of literature regarding their damping performance. This study analyzes the impact of oral cavity physiological parameters: temperature, pH, and swelling ratio on the mechanical properties of zinc-stabilized and zinc-free denture adhesives and examines the role zinc plays in influencing the adhesive behavior. This study investigates how underlying mechanical properties of adhesive cream change for zinc-stabilized and zinc-free denture adhesives. The relative damping and its variation from exposure to physiological conditions in the oral cavity can significantly assist in the design of dentures to reduce the discomfort experienced by denture wearers.

Materials and methods: The relative damping of the zinc-stabilized and zinc-free denture adhesives was investigated with the loss modulus values, which were evaluated using rheological frequency sweep tests. The tests were performed by maintaining the denture adhesives at specified values of temperature, pH, and swelling ratio, and over a frequency range of 0.01 Hz to 10 Hz, which included the average frequencies of human chewing / bite forces reported in existing literature.

Results: Zinc-stabilized denture adhesive showed a larger fluctuation of loss modulus values compared to the zinc-free formulation with respect to pH, temperature, and swelling ratios. The zinc-free denture adhesive showed higher damping behavior at frequencies below 0.7 Hz, whereas the zinc-stabilized denture adhesive showed higher damping behavior above loading frequencies of 0.7-1 Hz. Both the adhesives showed varying behavior on either side of the bite force spectrum in terms of relative damping of the applied bite.

Conclusions: The damping or cushioning effect provided by denture adhesives can reduce pain experienced and assist dental practitioners in better supporting denture wearers.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Impact of the Physiological Parameters of the Oral Cavity on the Mechanical Properties of Zinc-stabilized and Zinc-free Adhesive Creams: A Comparative In Vitro Study. Marginal Quality and Wear of Bulk-Fill Composites: Differences Between Dentitions. Effect of Pre-Procedural Antiseptic Mouthwash On The Dentin Bond Strength of Dental Adhesives. Hydrofluoric Acid in Dentistry: An Investigation of Isolation and Neutralizing Agents and Precipitates on IPS e.max CAD. Influence of Operator, Tool, Dental Loupes, and Tooth Position on Enamel Loss and Composite Remnants After Removal of Composite Attachments for Orthodontic Clear Aligners: An Experimental Study Using 3D Profilometry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1