Ultrasensitive Detection of Carcinogenic Chromium (VI) Species Below the WHO Limit Using a LaCeO₃/Carbon Black Screen Printed Electrode in Batch Injection Analysis

IF 3.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL Analyst Pub Date : 2025-03-11 DOI:10.1039/d5an00038f
Senthurvelan Saranya, Yashly Yesudas K, R.G. Stacey Sibiya, Buvaneswari Gopal, Annamalai Senthil Kumar
{"title":"Ultrasensitive Detection of Carcinogenic Chromium (VI) Species Below the WHO Limit Using a LaCeO₃/Carbon Black Screen Printed Electrode in Batch Injection Analysis","authors":"Senthurvelan Saranya, Yashly Yesudas K, R.G. Stacey Sibiya, Buvaneswari Gopal, Annamalai Senthil Kumar","doi":"10.1039/d5an00038f","DOIUrl":null,"url":null,"abstract":"The widespread industrial use of chromium and its subsequent release into the environment as toxic and carcinogenic hexavalent chromium (Cr(VI)) species pose significant risks to human health and the environment. The World Health Organization (WHO) has established a limit of 50 ppb (960 nM) for Cr (VI) in water samples. Developing simple, selective, and separation-free methods for the direct detection of Cr (VI) species in the environment remains a challenging task. Herein, we present a highly crystalline lanthanum cerate/carbon black chemically modified screen-printed electrode (SPE/CB@LaCeO3) as an effective electrochemical system for the high-performance and selective electrochemical reduction of toxic Cr(VI) species in pH 2 KCl-HCl solution. The CB@LaCeO3 composite is characterized by its high-density electroactive sites and enhanced electrical conductivity, which facilitate the efficient diffusion-controlled reduction of Cr(VI) species at a low reduction potential of 0.55 V vs Ag/AgCl. The modified electrode demonstrated stability and resistance to surface fouling during continuous voltammetry analysis of high Cr(VI) concentrations. A batch-injection analysis using a three-in-one screen-printed electrode, comprising carbon-working, silver-ink reference, and CB@LaCeO3 modified carbon working electrodes, exhibited excellent concentration linearity within the ranges of 5-30 ppb and 10-35 ppm, with a low detection limit of 682 ppt (signal-to-noise ratio, 3). This method was not interfered by dissolved oxygen or other common chemicals present in environmental and water systems. The linear range and detection limit achieved in this study surpass those reported in several previous works involving precious metal and organic molecule-based chemically modified electrodes. The analytical method was validated with t-test analysis. To demonstrate the applicability of this new system, batch injection analysis was performed on a wide range of real samples, including water (tap, ground, well, reverse osmosis), consumable products (coffee, tea and milk powders), and tannery effluent, using the standard addition method. This approach yielded accurate and sensitive detection of Cr(VI) species in the samples, with recovery values of approximately 100%.","PeriodicalId":63,"journal":{"name":"Analyst","volume":"25 1","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2025-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analyst","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1039/d5an00038f","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The widespread industrial use of chromium and its subsequent release into the environment as toxic and carcinogenic hexavalent chromium (Cr(VI)) species pose significant risks to human health and the environment. The World Health Organization (WHO) has established a limit of 50 ppb (960 nM) for Cr (VI) in water samples. Developing simple, selective, and separation-free methods for the direct detection of Cr (VI) species in the environment remains a challenging task. Herein, we present a highly crystalline lanthanum cerate/carbon black chemically modified screen-printed electrode (SPE/CB@LaCeO3) as an effective electrochemical system for the high-performance and selective electrochemical reduction of toxic Cr(VI) species in pH 2 KCl-HCl solution. The CB@LaCeO3 composite is characterized by its high-density electroactive sites and enhanced electrical conductivity, which facilitate the efficient diffusion-controlled reduction of Cr(VI) species at a low reduction potential of 0.55 V vs Ag/AgCl. The modified electrode demonstrated stability and resistance to surface fouling during continuous voltammetry analysis of high Cr(VI) concentrations. A batch-injection analysis using a three-in-one screen-printed electrode, comprising carbon-working, silver-ink reference, and CB@LaCeO3 modified carbon working electrodes, exhibited excellent concentration linearity within the ranges of 5-30 ppb and 10-35 ppm, with a low detection limit of 682 ppt (signal-to-noise ratio, 3). This method was not interfered by dissolved oxygen or other common chemicals present in environmental and water systems. The linear range and detection limit achieved in this study surpass those reported in several previous works involving precious metal and organic molecule-based chemically modified electrodes. The analytical method was validated with t-test analysis. To demonstrate the applicability of this new system, batch injection analysis was performed on a wide range of real samples, including water (tap, ground, well, reverse osmosis), consumable products (coffee, tea and milk powders), and tannery effluent, using the standard addition method. This approach yielded accurate and sensitive detection of Cr(VI) species in the samples, with recovery values of approximately 100%.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Analyst
Analyst 化学-分析化学
CiteScore
7.80
自引率
4.80%
发文量
636
审稿时长
1.9 months
期刊介绍: "Analyst" journal is the home of premier fundamental discoveries, inventions and applications in the analytical and bioanalytical sciences.
期刊最新文献
Back cover Rapid and reliable POCT blood typing based on laser identified RBC agglutination method A dual-trigger entropy drive circuit based on competitive hybridization for high-specific enzyme-free detection of single nucleotide polymorphisms Curcumin – A natural colorant-based colorimetric pH indicator for molecular diagnostics Ultrasensitive Detection of Carcinogenic Chromium (VI) Species Below the WHO Limit Using a LaCeO₃/Carbon Black Screen Printed Electrode in Batch Injection Analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1