A transient stability assessment method for power systems incorporating residual networks and BiGRU-attention

IF 1.9 Q4 ENERGY & FUELS Global Energy Interconnection Pub Date : 2025-02-01 DOI:10.1016/j.gloei.2024.09.001
Shan Cheng , Qiping Xu , Haidong Wang , Zihao Yu , Rui Wang , Tao Ran
{"title":"A transient stability assessment method for power systems incorporating residual networks and BiGRU-attention","authors":"Shan Cheng ,&nbsp;Qiping Xu ,&nbsp;Haidong Wang ,&nbsp;Zihao Yu ,&nbsp;Rui Wang ,&nbsp;Tao Ran","doi":"10.1016/j.gloei.2024.09.001","DOIUrl":null,"url":null,"abstract":"<div><div>The traditional transient stability assessment (TSA) model for power systems has three disadvantages: capturing critical information during faults is difficult, aperiodic and oscillatory unstable conditions are not distinguished, and poor generalizability is exhibited by systems with high renewable energy penetration. To address these issues, a novel ResGRU architecture for TSA is proposed in this study. First, a residual neural network (ResNet) is used for deep feature extraction of transient information. Second, a bidirectional gated recurrent unit combined with a multi-attention mechanism (BiGRU-Attention) is used to establish temporal feature dependencies. Their combination constitutes a TSA framework based on the ResGRU architecture. This method predicts three transient conditions: oscillatory instability, aperiodic instability, and stability. The model was trained offline using stochastic gradient descent with a thermal restart (SGDR) optimization algorithm in the offline training phase. This significantly improves the generalizability of the model. Finally, simulation tests on IEEE 145-bus and 39-bus systems confirmed that the proposed method has higher adaptability, accuracy, scalability, and rapidity than the conventional TSA approach. The proposed model also has superior robustness for PMU incomplete configurations, PMU noisy data, and packet loss.</div></div>","PeriodicalId":36174,"journal":{"name":"Global Energy Interconnection","volume":"8 1","pages":"Pages 143-159"},"PeriodicalIF":1.9000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Global Energy Interconnection","FirstCategoryId":"1087","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2096511725000015","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

The traditional transient stability assessment (TSA) model for power systems has three disadvantages: capturing critical information during faults is difficult, aperiodic and oscillatory unstable conditions are not distinguished, and poor generalizability is exhibited by systems with high renewable energy penetration. To address these issues, a novel ResGRU architecture for TSA is proposed in this study. First, a residual neural network (ResNet) is used for deep feature extraction of transient information. Second, a bidirectional gated recurrent unit combined with a multi-attention mechanism (BiGRU-Attention) is used to establish temporal feature dependencies. Their combination constitutes a TSA framework based on the ResGRU architecture. This method predicts three transient conditions: oscillatory instability, aperiodic instability, and stability. The model was trained offline using stochastic gradient descent with a thermal restart (SGDR) optimization algorithm in the offline training phase. This significantly improves the generalizability of the model. Finally, simulation tests on IEEE 145-bus and 39-bus systems confirmed that the proposed method has higher adaptability, accuracy, scalability, and rapidity than the conventional TSA approach. The proposed model also has superior robustness for PMU incomplete configurations, PMU noisy data, and packet loss.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Global Energy Interconnection
Global Energy Interconnection Engineering-Automotive Engineering
CiteScore
5.70
自引率
0.00%
发文量
985
审稿时长
15 weeks
期刊最新文献
Self-reduction multi-head attention module for defect recognition of power equipment in substation A coherent generator group identification algorithm under extreme conditions Flexible region aggregation of adjustable loads via an adaptive convex hull strategy Distribution network gray-start and emergency recovery strategy with pumped storage unit under a typhoon Integrated paralleling of NPC inverters with suppressed circulating current for high-power renewable energy conversion
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1